Aqua One Maxi 101 User Manual Download Page 7

7

Installation 101/102

All Aqua One Maxi Power Heads come fully 

assembled and ready to use.

1. Decide which outlet option to use.

a) If no attachment is required simply install the 

power head as is, or push the 13mm adapter 

or 13-9mm reducer into pump outlet.

b) If the venturi is required, push venturi outlet 

directly into pump outlet and hang the airline 

outside the aquarium.

2. Suction cups will fasten the powerhead to 

the wall of your aquarium.

3.  Use  flow  adjuster  on  the  bottom  of  the 

powerhead:

+ will allow full flow

- will reduce the flow

Remember the more flow the better.

Maintenance 101/102

Clean the impeller at least once a month.

Refer to the “Know You Filter” page for help 

with the following procedure.

1. Remove the power head from the aquarium 

and take it to the sink.

2. Grasp the motor with one hand and mounting 

bracket with the other and gently pull apart.

3. Remove the impeller cover to gain access 

to the impeller.

4. Pull impeller from the motor and rinse 

properly. Use an Aqua One double ended pipe 

brush to clean the impeller and the impeller 

well and also any of the outlet options that are 

being used.

5.  Put  the  power  head  back  together  and 

return to the aquarium. Ensure your hand is 

not wet, plug in at the power supply and turn 

on.

Fig 1

Fig 2

Fig 3

Fig 4

Summary of Contents for Maxi 101

Page 1: ...Maxi Powerheads 101 106 Instruction version 18 03 2015 www aquaone com au 2 1 Marine Tropical Coldwater ...

Page 2: ...wet do not unplug the appliance Disconnect the fuse or circuit breaker that supplies the power to the appliance then unplug and examine for presence of water in the socket 5 Always unplug the appliance from the electrical outlet when not in use before putting on or taking off parts before any type of maintenance or cleaning 6 Never yank the cable to pull it from the socket Pull the plug carefully ...

Page 3: ...antee service is required Carefully unpack the product making sure you keep all the packing material until all the parts of the product have been found and the product has been assembled Correct Positioning in Aquarium Set the powerhead up within the arrows indicated above The Powerhead must not be out of the water and must not be in contact with any substrate This product is shipped to you in a f...

Page 4: ...art you require Alternatively you will find these numbers on the silver label located on the product 101 Impeller 1I 102 Impeller 26I Know Your Power Head 101 102 1 Motor 2 Flow Controller 3 Impeller 4 Impeller Cover 5 Mounting Bracket Pre Filter 6 13mm Outlet 7 13 9mm Reducer 8 Venturi Outlet 9 Venturi Air Line Aqua One Spare Parts 1I 1 2 3 4 9 8 7 6 5 ...

Page 5: ...e spare part you require Alternatively you will find these numbers on the silver label located on the product 103 Impeller 27I 104 Impeller 28I Know Your Power Head 103 104 1 Motor 2 Impeller 3 Impeller Cover with Flow Controller 4 Mounting Bracket Pre Filter 5 16mm Outlet 6 Venturi Outlet 7 Venturi Air Line Aqua One Spare Parts 1I 1 2 3 4 7 6 5 ...

Page 6: ... for the spare part you require Alternatively you will find these numbers on the silver label located on the product 105 Impeller 29I 106 Impeller 30I Know Your Power Head 105 106 1 Motor 2 Mounting Bracket 3 Impeller 4 Impeller Cover 5 Lock 6 Pre Filter 7 21mm Inlet Hosetail 8 19mm Outlet Hosetail Aqua One Spare Parts 1I 1 2 3 4 8 7 6 5 ...

Page 7: ...the flow Remember the more flow the better Maintenance 101 102 Clean the impeller at least once a month Refer to the Know You Filter page for help with the following procedure 1 Remove the power head from the aquarium and take it to the sink 2 Graspthemotorwithonehandandmounting bracket with the other and gently pull apart 3 Remove the impeller cover to gain access to the impeller 4 Pull impeller ...

Page 8: ...the flow Remember the more flow the better Maintenance 103 104 Clean the impeller at least once a month Refer to the Know You Filter page for help with the following procedure 1 Remove the power head from the aquarium and take it to the sink 2 Graspthemotorwithonehandandmounting bracket with the other and gently pull apart 3 Remove the impeller cover to gain access to the impeller 4 Pull impeller ...

Page 9: ... sit the power head in the aquarium with the inlet attached to the up lift of the under gravel filter and attach the power head to the wall of the aquarium with the suction cups Maintenance 105 106 Clean the impeller at least once a month Refer to the Know You Filter page for help with the following procedure 1 Remove the power head from the aquarium and take it to the sink 2 Grasp the motor with ...

Page 10: ...rine Model Maxi 102 Dimensions 6 5x4 5x6 5cm Maximum Flow Rate 500L hr Max Head Height 1 05m Power Requirements 220 240V AC Power Consumption 8W Suitable Cold water Tropical Marine Model Maxi 103 Dimensions 10x6x8cm Maximum Flow Rate 1200L hr Max Head Height 1 2m Power Requirements 220 240V AC Power Consumption 15W Suitable Cold water Tropical Marine Model Maxi 104 Dimensions 11 5x7 5x9 5cm Maximu...

Page 11: ... on the applicable Aqua One website refer below 2 3 Upon receipt and acceptance of the questionnaire Aqua One will forward by way of email a Certificate of Extended Guarantee to the purchaser 2 4 For more information on how we collect hold use and disclose personal information provided to us please refer to our Privacy Statement on the Aqua One websites or write to our Privacy Officer in your coun...

Page 12: ...12 Inspiring Excellence in Fish Care ...