background image

Important Safeguards

This appliance is not intended for use by 
children or infirm persons without supervi-
sion. Young children should be supervised 
to ensure that they do not play with the 
appliance.

Warning: To guard against injury, basic 
safety precautions should be observed, 
including the following: 

1. Read and follow all safety instructions before 
using this appliance. 

2. Danger: To avoid possible electric shocks, 
special care should be taken since water is 
employed in the use of aquarium equipment. For 
each of the following situations do not attempt 
repairs yourself. Return the appliance to an 
authorised service facility for service or discard the 
appliance.

a) If the electrical components of the appliance get 
wet, unplug the appliance immediately (non 
immersible equipment only). 

b) If the overflow box or priming pump show any 
sign of abnormal water leakage, immediately 
unplug it from the power source. 

c) Carefully examine the overflow box and priming 
pump after installation. They should not be plugged 
in when there is water on parts which are not 
intended to be wet. 

d) Do not operate any aquarium accessory if it has 
a damaged cord or plug, or if it is malfunctioning, or 
dropped or damaged in any manner. 

A “drip loop” (See the diagram) should be arranged 
by the user for each cord connecting an aquarium 
component to a receptacle. The drip loop is the part 
of the cord below the level of the receptacle or the 
connector if an extension cord used. It is used to 
prevent water traveling along the cord and coming 
in contact with the receptacle. 
If the plug or receptacle does get wet, do not 
unplug the appliance. Disconnect the fuse or circuit 
breaker that supplies the power to the appliance, 
then unplug and examine for presence of water in 
the receptacle. 

3. Close supervision is necessary when the 
appliance is used by or near children. 

4. Always unplug the priming pump from the electri-
cal outlet; when not in use, before putting on or 
taking off parts, before any type of maintenance, or 
cleaning.

Never yank the cord to pull it from the outlet. Grasp 
the plug and unplug to disconnect. 

5. Do not use the overflow box or priming pump for 
reasons other than the intended use. The use of 
attachments that are not recommended or sold by 
the manufacturer may cause the product to be 
unsafe. This is not recommended. 

6. Do not install or store the overflow box or priming 
pump where they will be exposed to weather or 
temperatures below freezing. 

7. Make sure any component mounted on a tank is 
securely installed before operating it. 

8. Read and observe all the important notices on 
the unit. 

9. Ensure input voltage is the same voltage as your 
local power supply.  

10. If an extension cord is necessary, a cord with a 
proper rating should be used. Care should be taken 
to arrange the cord so that it will not be tripped or 
pulled.

11. A

 G.F.C.I

 (Ground fault circuit interrupter) & 

surge protector is recommended for all electrical 
appliances.

12. Ensure your hand is dry when turning the 
power switch on/off and when inserting/removing 
the power cord from the receptacle.

13. If you are in any doubt about the electrical 
installation or safety of this product you must 
consult a qualified electrician. 

For Guarantee Conditions, please refer to 

the Guarantee form at the back of this 

instruction booklet. 

Drip loop

2

Summary of Contents for MariSys Overflow Box

Page 1: ...Overflow Box Complete step by step instruction booklet ...

Page 2: ...If the plug or receptacle does get wet do not unplug the appliance Disconnect the fuse or circuit breaker that supplies the power to the appliance then unplug and examine for presence of water in the receptacle 3 Close supervision is necessary when the appliance is used by or near children 4 Always unplug the priming pump from the electri cal outlet when not in use before putting on or taking off ...

Page 3: ...p all the packing material until all the parts of the product have been found and the product has been assembled This product is shipped to you in a factory sealed carton Should the product malfunction in any way or if the unit is damaged and requires replacement contact the retailer where the product was purchased for inspection Replacement Parts Filter Media Use Aqua One Genuine Spare Parts Only...

Page 4: ...uarium 10 Water out To Filter 10 Water return Back to tank 5 Priming Pump 8 Water Bridge 11 Priming Chamber Duck Bill Outlet 7 V Joint 1 Complete Overflow Box Diagram 1 2 Water Level Adjuster 4 Screw Adjuster 1 Adjusting Screws 2 Diagram 2 ...

Page 5: ... Front Diagram 3 5 V Joint Duckbill Outlet Water Bridge Outlet to filter Overflow Box Outlet to tank Adjustment Hanging Bracket Priming Pump 3 Inlet Grid Pre Filter Pad Return to tank To Priming Pump Inlet From Overflow Box Airline Supports ...

Page 6: ... 1 2 3 on pages 4 5 of this instruction booklet 1 Position the filter unit in the stand cabinet under the aquarium or to the side next to the stand 2 Place the Overflow Box on the rear or side of the aquarium Initially the height of the box should be at its lowest setting The two Adjusting Screws 1 on each side will allow for the Overflow Box to be raised or lowered To lower the aquarium s water l...

Page 7: ... turn the system off whenever any maintenance is performed on the filter box or Overflow Box Do not use soap or detergents that can harm the tank inhabitants The Pre Filter Pad should be changed or rinsed every two to three weeks or as needed Priming Pump Maintenance 1 Flush the Priming Pump at least once a mounth 2 Disconnect the Pump from the V Joint on top of the Water Bridge leave the Air line...

Page 8: ...econnect and tighten hose clamps snugly 2 If the Flexible Hosing has slipped from original position remove and clean area then reconnect and tighten hose clamps snugly OVERFLOW BOX NOT FUNCTIONING 1 Check power supply and confirm Priming Pump is plugged in 2 No water in Overflow Box add water 3 Check Overflow Box for obstacles 4 Check Hosing and Tubing for kinks or obstructions PRIMING PUMP NOT RU...

Page 9: ...ns 4 Replacement equipment is guaranteed for the remainder of the original manufacturer s guarantee period Guarantee does not cover a Cost of freight postage or the cost of insurance b Service costs arising from failure to correctly adjust the controls of the product or to clean the hoses filter media impellers power heads failure to observe the manufacturer s instructions or inspections that reve...

Page 10: ...52 Glenlyon Avenue Greerton Tauranga New Zealand Distributed in Hong Kong by Kong s Aquarium Supplies Co Ltd No 31 3 F Thriving Industrial Centre 26 38 Sha Tsui Road Tsuen Wan Hong Kong Distributed in the UK by Kong s UK Limited C O Aqua Pacific UK Ltd PO Box 268 Romsey Hampshire SO51 0WW United Kingdom www aquaone com au Aqua One and Kong s are registered trademarks Maximum Pump Operating flow ra...

Page 11: ...Instruction Version 30 10 06 www aquaone com au ...

Page 12: ......

Reviews: