Before First Use / Preparation

Hints & Tips

IMPORTANT INFORMATION

The  maximum  ambient  temperature  is  50°C.  This 

chiller is rated to decrease the water temperature 

by  up  to  7-8°C  for  the  listed  aquarium  volume.  If 

the  chiller  is  used  inside  a  cabinet,  there  must 

be adequate ventilation in the cabinet for heat to 

escape. At minimum you should consider utilising 

at  least  two  cross  flowing  vents  in  the  cabinet 

ideally with an exhaust fan for heat removal.

Read  and  follow  all  the  instructions,  even  if  you  feel 

you  are  familiar  with  the  product  and  find  a  place  to 

keep  the  instructions  handy  for  future  reference. 

Your  attention  is  drawn  particularly  to  the  sections 

concerning 

“IMPORTANT  SAFEGUARDS”

  and  the 

“GUARANTEE  CONDITIONS”

.  Please  ensure  you 

retain your original purchase receipt in the event that 

guarantee  service  is  required.Carefully  unpack  the 

filter making sure you keep all the packing material until 

all the parts of the product have been found and the 

product has been assembled.

This  product  is  shipped  to  you  in  a  factory  sealed 

carton.  Should  the  product  malfunction  in  any  way 

or  if  the  unit  is  damaged  and  requires  replacement, 

contact the retailer where the product was purchased 

for inspection.

1. Place the unit on a level surface.

2. Allow adequate ventilation. Allow sufficient clearence 

to the front and sides of the chiller to allow adequate 

air flow.

3.  Do  not  cover  the  unit.  Covering  the  vents  on  the 

front,  back  and  sides  of  the  chiller  could  cause  the 

unit to overheat and will prevent the unit from cooling 

efficiently.

4. Do not place items on top of the chiller.

5. Keep the chiller away from direct sunlight, moisture, 

dust and flammable materials.

6. Do not tilt the chiller. If the unit has been transported 

or stored on the side it must be left upright for 24-48hrs 

before being turned on.

7.  Heat  is  generated  by  light  units,  especially  metal 

halides  as  well  as  submersible  pumps  and  other 

electrical  equipment.  Consider  the  heat  input  of 

these items and consider switching off some of these 

components in extreme heat conditions.

Summary of Contents for Arctic 1/6HP

Page 1: ...Arctic Chiller Inspiring Excellence in Fish Care www aquaone com au 1 6HP 1 3HP 3 5HP Instruction version 13 10 2010 ...

Page 2: ...ppliance Disconnect the fuse or circuit breaker that supplies the power to the appliance then unplug and examine for presence of water in the socket 5 Always unplug the appliance from the electrical outlet when not in use before putting on or taking off parts before any type of maintenance or cleaning 6 Never yank the cable to pull it from the socket Pull the plug carefully to disconnect 7 Do not ...

Page 3: ...ts of the product have been found and the product has been assembled This product is shipped to you in a factory sealed carton Should the product malfunction in any way or if the unit is damaged and requires replacement contact the retailer where the product was purchased for inspection 1 Place the unit on a level surface 2 Allow adequate ventilation Allow sufficient clearence to the front and sid...

Page 4: ...lug has been disconnected It is recommended to clean the intakes on the chiller once a month Failure to do so may cause the chiller to overheat and suffer permanent damage In order to clean the unit remove the plastic covers then using a soft bristled brush throughly brush the entire grill Vacuum the area to remove any dust dirt that has come loose CAUTION When cleaning the chiller do not use wate...

Page 5: ...utlets The unit will not operate if air temperature is above the maximum operating temperature Trouble Shooting Specifications Chiller Model Arctic 1 6HP Dimensions 39x32x46cm Max Aquarium Volume 300L Flow Rate 800 2200L hr Inlet Outlet Size 19mm Power Requirements 220 240V Power 1 6HP Refrigerant R134A Suitable Marine Chiller Model Arctic 1 3HP Dimensions 46x39x52cm Max Aquarium Volume 650L Flow R...

Page 6: ...try of purchase 2 5 Where Aqua One determines goods are being used in a manner contrary to the instructions specifications or this Guarantee Aqua One reserves the right to terminate Extended Guarantee for such goods and will provide written notice to the purchaser 3 0 Exclusions and Limitations Where permitted by local law the following exclusions and limitations apply in regard to Guarantee 3 1 G...