Aqua One 250C Safety Instructions Download Page 2

2

GB

Important Safeguards

To  guard  against  injury,  basic  safety  precautions 

should be observed, including the following:

1. Read and follow all safety instructions before using 

this appliance.

2.  Danger: To  avoid  possible  electric  shocks,  special 

care should be taken since water is employed in the 

use of aquarium equipment, for each of the following 

situations do not attempt repairs yourself. Return the 

appliance to an authorised service facility for service or 

discard the appliance.

3.  This  appliance  is  not  intended  for  use  by  young 

children  or  infirm  people.  Close  supervision  is 

recommended when any electrical appliance is used.

4.  Do  not  use  the  pump  for  reasons  other  than  the 

intended  use.  The  use  of  attachments  that  are  not 

recommended  or  sold  by  the  pump  manufacturer 

may  cause  the  product  to  be  unsafe.  This  is  not 

recommended.

5.  Do  not  install  or  store  the  pump  where  it  will  be 

exposed to temperatures below freezing.

6. Make sure any component mounted on or in a tank 

is securely installed before operating it.

7. Ensure the correct batteries are installed and replace 

both batteries when old ones expire.

Before First Use / 

Preparation

Read  and  follow  all  the  instructions,  even  if  you  feel 

you  are  familiar  with  the  product  and  find  a  place  to 

keep  the  instructions  handy  for  future  reference. 

Your  attention  is  drawn  particularly  to  the  sections 

concerning 

“IMPORTANT  SAFEGUARDS”

  and  the 

“GUARANTEE  CONDITIONS”

.  Please  ensure  you 

retain your original purchase receipt in the event that 

guarantee service is required.

Carefully unpack the product making sure you keep all 

the packing material until all the parts of the product have 

been found and the product has been assembled.

This  product  is  shipped  to  you  in  a  factory  sealed 

carton.  Should  the  product  malfunction  in  any  way 

or  if  the  unit  is  damaged  and  requires  replacement, 

contact the retailer where the product was purchased 

for inspection.

Setup Instructions

Remove the pump from the plastic bag

1. 

Using  your  thumb  depress  the  side  wall  of  the 

2. 

pump and open the lid.

Take out the accessory pack.

3. 

Install 2 x D batteries (not supplied). Make certain 

4. 

they are in the right way.

Close the pump, it should “click”.

5. 

Remove  the  airline  and  airstone  from  the  plastic 

6. 

bag. Plug the airstone into one end of the airline. 

Plug the other end of the airline into the outlet of 

the pump.

Where possible place the pump above the aquarium 

7. 

or bucket. If this is not possible then ensure that an 

Aqua One check valve is fitted to the airline, failure 

to do so may damage your air pump & void your 

warranty.

Flick the switch to the “on” position to operate the 

8. 

pump.

If the pump needs to be used in a vehicle, plug the 

9. 

supplied  power  cable  into  the  vehicle’s  cigarette 

lighter  outlet  and  connect  the  other  end  to  the 

power socket on the side of the air pump. When 

the 12V cable is connected, power will be drawn 

from the power supply, not the batteries. 

Troubleshooting

PUMP DOES NOT WORK

1.  Ensure  the  plug  and/or  batteries  are  inserted 

correctly and the switch is in the on position

THE MOTOR IS WORKING, BUT THERE IS NO AIR 

COMING OUT OF THE PUMP

1. Check that the Air Line is not kinked

2. Check the Air Stone and replace if needed.

3. There is a rubber diaphragm inside the pump which 

may have warn out and may require replacing. Consult 

your Aqua One retailer.

4. The Flapper valves in the pump may have become 

dirty or brittle and require replacing. Consult your Aqua 

One retailer.

THE PUMP IS VERY NOISY

1. Check that the Air Line is not kinked

2. Check the Air Stone and replace if needed.

3. There is a rubber diaphragm inside the pump which 

may have warn out and may require replacing.

4. There may be to much back pressure on the pump. 

(It is to small for your application)