Aqua Medic T5 sunbeam Operation Manual Download Page 6

 

5.

 

Lamp’s assembly / change of lamps  

 
When  changing  the  fluorescent  lamp,  first  of  all  the  socket rings have to be released and pushed 
over the pipe. Now, the pipe can be taken out.  
When assembling the new fluorescent lamp, first of all the socket rings have to be pushed on the 
pipe. Then the lamp can be inserted.  
 
Please make sure that the socket rings are mounted tightly on the pipe when mounting the lamp. 
The  lamps  are  only  waterproof  if  the  rings  are  mounted  correctly.  Also  pay  attention  that  the 
sealing at the socket ring is mounted correctly.  
 
Only  turn  on  the  light  when  the  fluorescent  lamp  is  mounted  and  the  socket  rings  are  fastened 
tightly. Replace broken socket rings by new original ones by AB Aqua Medic.  
 

6.

 

Assembly  

 

There are 2 different ways of mounting the sunbeam:  
 
1.

 

Mounting  directly  underneath  the  aquarium  cover.  To  do  so,  wood  screws  (not  included  in 
shipment) are screwed through the end caps into the base (e. g. wood cover).  

 

2.

 

It can be mounted onto the ceiling by AB Aqua Medic’s suspension kit aquafit (not included in 
shipment). The suspension has to be screwed into the appropriate threaded holes of the end 
caps. 

 

7. Maintenance and Care 
 

The service life of T5 bulbs will be about 6,000 to 8,000 hours. This corresponds to about 1,5 years 
with  a  daily  illumination  time  of  10  hours.  It  is  recommended  to  exchange  the  bulbs  before 
expiration of this time interval since efficiency and colour composition change.  
 
Clean the sunbeam from time to time using a moistened cloth. Never use any additional cleaning 
agents!   
 

8. Warranty 

 
Should any defect in material or workmanship be found within 12 months of the date of purchase 
AB  Aqua  Medic  GmbH  undertakes  to  repair  or,  at  our  option,  replace  the  defective  part  free  of 
charge – always provided the product has been installed correctly, is used for the purpose that was 
intended by us, is used in accordance with the operating instructions and is returned to us carriage 
paid. The warranty term is not applicable on the all consumable products.  
Proof of Purchase is required by presentation of an original invoice or receipt indicating the dealer’s 
name, the model number and date of purchase, or a Guarantee Card if appropriate. This warranty 
may  not  apply  if  any  model  or  production  number  has  been  altered,  deleted  or  removed, 
unauthorised  persons  or  organisations  have  executed  repairs,  modifications  or  alterations,  or 
damage is caused by accident, misuse or neglect.  
We regret we are unable to accept any liability for any consequential loss. 
Please note that the product is not defective under the terms of this warranty where the product, 
or any of its component parts, was not originally designed and / or manufactured for the market in 
which it is used. 
These statements do not affect your statutory rights as a customer. 
If  your  AB  Aqua  Medic  GmbH  product  does  not  appear  to  be  working  correctly  or  appears  to  be 
defective please contact your dealer in the first instance. 
Before calling your dealer please ensure you have read and understood the operating instructions. 
If you have any questions your dealer cannot answer please contact us. 
 
Our policy is one of continual technical improvement and we reserve the right to modify and adjust 
the specification of our products without prior notification. 

 

AB Aqua Medic GmbH - Gewerbepark 24 - 49143 Bissendorf/Germany 

- Technical changes reserved – 10/2010 

 
 

Summary of Contents for T5 sunbeam

Page 1: ...auch entwickelt und erprobt worden Hochwertige Technik und beste Materialien sowie modernes Design gewährleisten dass Sie lange Freude an Ihrer Aquarienbeleuchtung haben werden GmbH Gewerbepark 24 49143 Bissendorf Germany __________________________________________________________________________________________ 60 cm 2 x 24 W 90 cm 2 x 39 W 120 cm 2 x 54 W 150 cm 2 x 80 W ...

Page 2: ...Reparaturversuche sondern schicken Sie die Leuchte zur Prüfung ggfs mit einer Mängelbeschreibung ein Fassungsringe müssen immer montiert und fest angezogen werden Niemals ohne Fassungsringe betreiben 3 Auspacken Prüfen Sie die Leuchte nach dem Auspacken auf etwaige Beschädigungen Bei Beanstandungen wenden Sie sich bitte unverzüglich an Ihren Fachhändler 4 Leuchtmittel Die Leuchten werden ohne Leuc...

Page 3: ...n Gewindelöcher der Endkappe geschraubt 7 Wartung und Pflege Die Standzeit der T5 Röhren beträgt ca 6 000 8 000 Stunden Dies entspricht etwa 1 5 Jahren bei einer täglichen Brennzeit von 10 Stunden Tauschen Sie die Röhren möglichst noch vor Ablauf dieser Zeitspanne aus da sich Leistung und Farbzusammensetzung verändern Reinigen Sie die sunbeam von Zeit zu Zeit mit einem feuchten Tuch Verwenden Sie ...

Page 4: ...arium use and been tested by experts High quality components and latest technology as well as modern design guarantee for enjoying your aquarium lighting for many years GmbH Gewerbepark 24 49143 Bissendorf Germany __________________________________________________________________________________________ 60 cm 2 x 24 W 90 cm 2 x 39 W 120 cm 2 x 54 W 150 cm 2 x 80 W ...

Page 5: ...ghting system yourself but send it to AB Aqua Medic for checking preferably together with a list of defects The socket rings have always to be mounted and fastened tightly Don t take the lamp into operation without socket rings 3 Unpacking On unpacking please check the lighting system immediately for any damages In case of any complaints please contact your dealer directly 4 Lamps The lighting sys...

Page 6: ...kmanship be found within 12 months of the date of purchase AB Aqua Medic GmbH undertakes to repair or at our option replace the defective part free of charge always provided the product has been installed correctly is used for the purpose that was intended by us is used in accordance with the operating instructions and is returned to us carriage paid The warranty term is not applicable on the all ...

Reviews: