Aqua Medic T controller CC Operation Manual Download Page 6

6. Technical Data 
 

Display: 

0.5“ LED, 3.5 digits  

Measurement range: 

0 - 100° C 

Resolution: 

0.1° C 

Measurement accuracy: 

+ 0.1 C (+ 1 digit) 

Loading capacity of contact:  1,000 Watt at 230 V    
Humidity: 

below 80% 

Adjustment range: 

0 - 40° C, digitally adjustable 

Adjustment accuracy: 

+/- 0,4 °C (+ 1 digit) 

Power requirements: 

230 V/50 Hz 

Dimensions: 

150 x 85 x 40 mm 

Weight: 

550 g 

 
7. Warranty 
 

Should any defect in material or workmanship be found within 12 months of the date of purchase 
AB  Aqua  Medic  GmbH  undertakes  to  repair  or,  at  our  option,  replace  the  defective  part  free  of 
charge – always provided the product has been installed correctly, is used for the purpose that was 
intended by us, is used in accordance with the operating instructions and is returned to us carriage 
paid. The warranty term is not applicable on the all consumable products.  
Proof of Purchase is required by presentation of an original invoice or receipt indicating the dealer’s 
name, the model number and date of purchase, or a Guarantee Card if appropriate. This warranty 
may  not  apply  if  any  model  or  production  number  has  been  altered,  deleted  or  removed, 
unauthorised  persons  or  organisations  have  executed  repairs,  modifications  or  alterations,  or 
damage is caused by accident, misuse or neglect.  
We regret we are unable to accept any liability for any consequential loss.  
Please note that the product is not defective under the terms of this warranty where the product, 
or any of its component parts, was not originally designed and / or manufactured for the market in 
which it is used. 
These statements do not affect your statutory rights as a customer. 
 
If  your  AB  Aqua  Medic  GmbH  product  does  not  appear  to  be  working  correctly  or  appears  to  be 
defective please contact your dealer in the first instance. 
Before calling your dealer please ensure you have read and understood the operating instructions. 
If you have any questions your dealer cannot answer please contact us. 
 
Our policy is one of continual technical improvement and we reserve the right to modify and adjust 
the specification of our products without prior notification. 
 

AB Aqua Medic GmbH - Gewerbepark 24 - 49143 Bissendorf/Germany 

- Technical changes reserved – 11/2014

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for T controller CC

Page 1: ...Sie sich f r ein Qualit tsinstrument entschieden Es ist speziell f r den aquaristischen Gebrauch entwickelt worden Mit diesem Ger t sind Sie in der Lage die Temperatur Ihres Aquarienwassers kontinuier...

Page 2: ...5 Thermosensor fest angeschlossen 6 220 V Stecker Steckdose f r Regelglied K hlung 4 Inbetriebnahme 220 V Anschluss herstellen Schalter 3 auf T stellen Temperaturanzeige Messf hler im Aquarium fest an...

Page 3: ...t kostenlos durch Einbau neuer oder erneuerter Teile instandsetzen ausgenommen Frachtkosten Im Fall dass w hrend oder nach Ablauf der Garantiezeit Probleme mit Ihrem Ger t auftreten wenden Sie sich bi...

Page 4: ...ting unit you have selected a top quality product It has been specifically designed for aquaristic purposes With this unit you can continuously measure and control the temperature of the water in your...

Page 5: ...knob 4 Set knob for adjustment 5 Temperature sensor for adjustment 6 Power plug 4 Installation Connect to 220 V power source Set the switch 3 to T display of temperature Place the temperature sensor...

Page 6: ...if appropriate This warranty may not apply if any model or production number has been altered deleted or removed unauthorised persons or organisations have executed repairs modifications or alteration...

Page 7: ...lation vous avez choisi un produit de qualit sup rieure Il a t sp cifiquement con u dans un but aquariophile Il vous permettra de mesurer et de contr ler en continu la temp rature de l eau de votre aq...

Page 8: ...e et de valeur nominale 4 R glage de valeur nominale 5 Sonde attach solidement 6 Prise de courant 220 V prise pour membre r glementaire refroidissement 4 Installation Connectez une alimentation 220 V...

Page 9: ...pareil est remis gratuitement en tat par change de pi ces neuves ou r nov es hors frais de transport Si durant ou apr s la dur e de la garantie des probl mes apparaissent avec l appareil adressez vous...

Page 10: ...le e il dispositivo di regolazione avete scelto un prodotto di altissima qualit E stato specificatamente progettato per scopi acquaristici Con questo prodotto potrete misurare e controllare la tempera...

Page 11: ...rruttore di taratura per la regolazione 5 Sensore di temperatura 6 Spina della corrente 3 Installazione Collegare a una sorgente di corrente di 230 V Posizionare l interruttore 3 su T visualizzazione...

Page 12: ...di acquisto oppure se il caso il cartoncino della garanzia Questa Garanzia decade se il numero del modello o di produzione alterato cancellato o rimosso se persone o enti non autorizzati hanno eseguit...

Reviews: