background image

5. Mounting 
 

The pump may be installed submerged or out of the water. However, it is not self-priming and, if set 

up  out  of  the  water,  has  to  be  installed  below  the  water  surface  level.  If  used  submerged,  we 
recommend to remove the hose connection (Fig. 2, No. 13) on the suction side and to fit the filter 
basket (Fig. 2, No. 11) in front of the pump. However, it must be prevented that the pump runs dry 
since this would destroy the bearings after a short period.  

 
The bottom plate (Fig. 2, No. 20) with the rubber suckers (Fig. 2, No. 19) can be fitted to the pump 

on 3 sides so the outlet positioned can be adjusted. After setting up the pump, please ensure you 
can always reach the power plug easily. 

 

Maximum depth must not exceed 1 m. 

                 

A                                                                                

     B 

 
Fig. Examples: (A) out of water and (B) submerged set up. 

 

 

 
 
 
 
 
 
 

 

 

 
6. Maintenance / Cleaning 
 
CAUTION: 

Disconnect the power before you start any work on the pump. 

 
The pump is designed to have a low maintenance requirement and under normal conditions, will be 

very reliable. However, the filter housing and all rotating parts must be cleaned regularly (Fig. 2, No. 
1 to 5). To do so, remove the pipe connections and undo the bayonet (Fig. 2, No. 6) on the pump 
housing. Now, remove the lid of the pump housing (Fig. 2, No. 7).  

 

Caution:

 This part is tight fit because it has an “O” ring seal and must be removed carefully so as 

not to break the ceramic shaft (Fig. 2, No. 4). The complete impeller (Fig. 2, No. 2 and 3) can be 
taken out, cleaned under running water and then be re-assembled. 

 

7. Failures 
 

If the pump fails to operate, check the power connection and fuse. If no fault is found, the pump 

may be blocked and must be cleaned. See maintenance / cleaning above. If the pump is noisy, the 
pump head (Fig. 2, No. 1 and 5) has to be cleaned. If the impeller is damaged, it can be changed. 
The impeller (Fig. 2, No. 3) can be removed from the magnet (Fig. 2, No. 2). 

 

Safety advices        

 

The pump is constructed for indoor aquarium use only. Before working on the  
aquarium or pump, the power plug must be disconnected from the mains. The  
connection cable and the power plug must not be changed. If the power cable  
is damaged, the pump must be scrapped. 
 
If the pump is used submerged, the filter (Fig. 2, No. 11,12), tube and /or hose connection  
(Fig. 2, No. 13) must be used. 
 

Summary of Contents for Ocean Runner OR 3500

Page 1: ...Kauf dieser Pumpe haben Sie sich f r ein Qualit tsger t entschieden Sie ist speziell f r den aquaristischen Gebrauch entwickelt und von Fachleuten erprobt worden AB Aqua Medic GmbH Gewerbepark 24 491...

Page 2: ...engewinde Anschluss Saugseite Au engewinde alternativ Klebemuffe DN25 1 1 1 Kabell nge in m Schutzklasse Schutzart 3 I IP 68 3 I IP 68 Gr te Betriebstauchtiefe 1 m 1 m 1 m 1 m Max Medientemperatur 35...

Page 3: ...auf den Druckstutzen geschraubt Bei fester Verrohrung empfehlen wir zur Entkoppelung von Vibrationen zumindest ein St ck mit flexiblem Schlauch zu verlegen Abb 2 Ocean Runner Pumpen 4 Aufbau der Pumpe...

Page 4: ...zu Zeit gereinigt werden Zun chst werden die Anschl sse demontiert Jetzt kann der Bajonettverschluss Abb 2 Nr 6 am Kreiselgeh use ge ffnet werden Der Verschluss des Pumpengeh uses Abb 2 Nr 7 l sst sic...

Page 5: ...Ger t auftreten wenden Sie sich bitte an Ihren Fachh ndler Diese Garantie gilt nur f r den Erstk ufer Sie deckt nur Material und Verarbeitungsfehler die bei bestimmungsgem em Gebrauch auftreten Sie g...

Page 6: ...uaria In purchasing this pump you have selected a top quality product It has been specifically developed for aquarium use and extensively tested by experts AB Aqua Medic GmbH Gewerbepark 24 49143 Biss...

Page 7: ...3 2 m 6 500 108 3 8 m Connection pressure side male thread Connection suction side male thread alternatively adhesive fitting DN25 1 1 1 Cable length m Protection class Protection rating 3 I IP 68 3 I...

Page 8: ...ng of the pump If a hard pipe is used for connecting the pumps we recommend to use a short section of flexible hose to avoid vibrations 4 Exploded parts diagram Fig 2 Ocean Runner pumps Parts List 1 M...

Page 9: ...nd all rotating parts must be cleaned regularly Fig 2 No 1 to 5 To do so remove the pipe connections and undo the bayonet Fig 2 No 6 on the pump housing Now remove the lid of the pump housing Fig 2 No...

Page 10: ...warranty may not apply if any model or production number has been altered deleted or removed unauthorised persons or organisations have executed repairs modifications or alterations or damage is cause...

Page 11: ...u douce L achat de cette pompe correspond celui d un appareil de qualit Elle a t sp cialement con ue pour l usage aquariophile et test e par des professionnels AB Aqua Medic GmbH Gewerbepark 24 49143...

Page 12: ...on m le ou glue joint DN25 1 1 1 Longueur du c ble en m Classe de protection Type de protection 3 m 10 ft I IP 68 3 m 10 ft I IP 68 Profondeur max 1 m c 3 ft 1 m c 3 ft Temp rature moyenne maxi 35 C 3...

Page 13: ...de tuyau flexible afin d viter toute vibration 4 Sch ma de la pompe Connexion OR 3500 Fig 2 Ocean Runner pompes 1 Bloc moteur 2 Rotor 3 Roue 4 Axe c ramique 5 Joint 6 Fermeture ba onnette 7 Corps de p...

Page 14: ...fusible Si aucun d faut n est constat la pompe peut tre bloqu e et doit tre nettoy e tez toutes les connexions et ouvrez la fermeture ba onnette du corps de la pompe Fig 2 No 6 Maintenant la connexion...

Page 15: ...tre revendeur Cette garantie ne vaut que pour le premier acheteur Elle ne couvre que les d fauts de mat riau et ou de fabrication qui peuvent se produire lors d une utilisation normale Elle n est pas...

Page 16: ...Con la compra de esta bomba usted ha elegido un art culo de m xima calidad Ha sido espec ficamente dise ada para su uso en acuarios y extensamente comprobada por expertos AB Aqua Medic GmbH Gewerbepa...

Page 17: ...00 108 3 8 m Conexi n lado presi n rosca macho Conexi n lado absorci n rosca macho alternatively adhesive fitting DN25 1 1 1 Longuitud del cable Tasa de protecci n Tipo de protecci n 3 I IP 68 3 I IP...

Page 18: ...recomendamos usar una manguera corta flexible para evitar vibraciones 4 Partes de la bomba Fig 2 Bombas Ocean Runner Conexi n de manguera OR 3500 1 Cubierta de motor 2 Rotor magn tico 3 H lice 4 Eje c...

Page 19: ...piadas regularmente Retire las conexiones y abra el cierre de bayoneta Fig 2 No 6 situado en el lateral de la bomba Ahora la conexi n de succi n Fig 2 No 7 puede ser retirada Atenci n Esta parte es he...

Page 20: ...erado por personal no autorizado el da o se ha causado por accidente uso indebido o negligencia No nos responsabilizamos de ninguna p rdida accidental Por favor aseg rese de que el producto no sea def...

Page 21: ...rina Acquistando questa pompa avete scelto un prodotto di altissima qualit studiato e sviluppato appositamente per l uso in acquari e testato dai nostri esperti AB Aqua Medic GmbH Gewerbepark 24 49143...

Page 22: ...m c 10 5 ft 6 500 l h 108 l m c 1 700 gph 3 8 m c 12 5 ft Connesisone a pressione filettatura maschio Connessione aspirazione filettatura maschio O congiunzione a colla DN25 1 1 1 Lunghezza del cavo C...

Page 23: ...a 1 Se si utilizza un tubo rigido per la connessione delle pompe raccomandiamo l uso di una sezione parziale di tubo flessibile per evitare vibrazioni 4 Diagramma parti Fig 2 Lista parti 1 Alloggiamen...

Page 24: ...overe la connessione d aspirazione Fig 2 No 7 Attenzione Questa parte generalmente molto resistente all apertura a causa della guarnizione a sigillo e si deve quindi procedere con cautela per non romp...

Page 25: ...ro del modello e la data di acquisto La garanzia potrebbe non essere applicata in caso il numero del modello o di produzione siano stati alterati cancellati o rimossi in caso vengano rilevate modifich...

Page 26: ...26 Ocean Runner OR 3500 and 6500 RUS AB Aqua Medic GmbH Gewerbepark 24 49143 Bissendorf Germany ___________________________________________________________________________________________...

Page 27: ...8 180 3 500 58 3 2 m 6 500 108 3 8 m DN 25 1 1 1 3 I IP 68 3 I IP 68 1 m 1 m 1 m 1 m 35 C 35 C OR 3500 3 OR 6500 4 Fig 1 Ocean Runner 3 Fig 2 No 13 Fig 2 No 7 Fig 2 No 15 16 OR 3500 Fig 2 No 17 Tangit...

Page 28: ...00 DN 25 17 1 4 Fig 2 Ocean Runner pumps 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 4 20 OR 6500 15 15a 16 17 18 21 www aqua medic de 13 2 3 1 5 6 12 8 10 14 17 16 15 18 4 19 4x 20 7 9 11 OR 6500...

Page 29: ...29 5 1 13 1 6 Fig 2 No 11 12 Fig 2 No 13 7 AB Aqua Medic GmbH 24 AB Aqua Medic GmbH AB Aqua Medic GmbH Gewerbepark 24 49143 Bissendorf Germany 10 2016...