background image

 

 

    Light Computer  

 

 

Mode d’emploi  F 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
Le Light Computer d’Aqua Medic est un appareil électronique qui gère l’éclairage des aquariums et 
des  terrariums.  Il  se  caractérise  principalement  par  sa  fonction  de  gestion  du  cycle  (phases) 
lunaire. S’approchant du rythme naturel des animaux et des plantes, il stimule ainsi leur croissance 
te leur reproduction. 
 

AB Aqua Medic GmbH

 

GmbH

 

Gewerbepark 24, 49143 Bissendorf, Allemagne 

___________________________________________________________________

 

Summary of Contents for Light Computer

Page 1: ...n Kennzeichen ist das mondphasengesteuerte Mondlicht das den natürlichen Mondphasenzyklus simuliert und die Tiere und Pflanzen in einen natürlichen Rhythmus bringt Oft wird hierdurch die Fortpflanzung stimuliert oder induziert AB Aqua Medic GmbH GmbH Gewerbepark 24 49143 Bissendorf Germany ___________________________________________________________________ ...

Page 2: ...te Zyklus für das Mondlicht Tageslicht Kanal 1 mit je 1 Ein und Ausschaltzeit für die Hauptbeleuchtung z B Metallhalogendampflampe Belastbarkeit 6 A 750 Watt relaisgesteuert Kanal 2 mit je 1 Ein und Ausschaltzeit für die Nebenbeleuchtung z B Leuchtstofflampen Belastbarkeit 1 6 A 150 Watt Mondlicht Kanal 3 für 230 V Glühlampe max 100 Watt Die Mondphasensteuerung ist an Kanal 1 gekoppelt Zum Erzeuge...

Page 3: ...hrzeit Mit den und Tasten die aktuelle Uhrzeit einstellen Speicherung der Uhrzeit durch nochmaliges Drücken der TIME DATE Taste Die Uhrzeit wird jetzt ohne Blinken angezeigt 5 2 Beleuchtung Bei der Programmierung von Tagesbeleuchtung und Mondlicht sind folgende Programmierpunkte anzeigen zu berücksichtigen A1 Einschaltzeit von Kanal 1 Hauptbeleuchtung HQI A2 Ausschaltzeit von Kanal 1 A3 Einschaltz...

Page 4: ...elöscht und neu programmiert werden Stecker ziehen Nach ca 10 Sekunden TIME DATE Taste drücken und halten Stecker wieder einstecken Jetzt sind alle Werte auf ihre Ausgangswerte gesetzt der Light Computer kann neu programmiert werden Wenn ein Schaltausgang z B nach einer Überlastung durch zu hohe Leistung der angeschlossenen Lampen ausfällt muss das Gerät eingeschickt werden 7 Garantie AB Aqua Medi...

Page 5: ...aquaria and terraria The main feature is the ability to program cycles phases of the moon This supports the natural rhythm of animals and plants Their reproduction will be stimulated or induced AB Aqua Medic GmbH GmbH Gewerbepark 24 49143 Bissendorf Germany ___________________________________________________________________ ...

Page 6: ...d requirement of 6 Amp 750 Watt Channel 2 For every single on and off time for the secondary lighting i e fluorescent lamps is a load requirement 1 6 Amp 150 Watt Moonlight Channel 3 For 230 Volt light bulbs maximum 100 W This channel is dependent on channel 1 In order to generate a natural twilight the moonlight works before the switchoff of the main lighting channel 1 initially parallel with ful...

Page 7: ...t time in the same manner as date Press TIME DATE button to store the current time 5 2 Lighting For programming adjustment of day and moon light consider the following displays A1 On time of channel 1 main lighting metal halide lamps A2 Off time of channel 1 A3 On time of channel 2 secondary lighting fluorescent lamps A4 Off time of channel 2 II 1 Intro time of the moonlight coupled with A1 and A2...

Page 8: ...structions and is returned to us carriage paid The warranty term is not applicable on the all consumable products Proof of Purchase is required by presentation of an original invoice or receipt indicating the dealer s name the model number and date of purchase or a guarantee card if appropriate This warranty may not apply if any model or production number has been altered deleted or removed unauth...

Page 9: ...rrariums Il se caractérise principalement par sa fonction de gestion du cycle phases lunaire S approchant du rythme naturel des animaux et des plantes il stimule ainsi leur croissance te leur reproduction AB Aqua Medic GmbH GmbH Gewerbepark 24 49143 Bissendorf Allemagne ___________________________________________________________________ ...

Page 10: ...clairage principal par ex HQI sous 6 A 750 W maxi Canal 2 Gestion de l allumage et de l extinction de l éclairage secondaire par ex tube bleu actinic sous 1 6 A 150 W maxi Nuit Canal 3 Pour un éclairage incandescent 230 V de 100 W maxi Dépend du canal 1 Afin recréer un crépuscule lunaire naturel avant l extinction de l éclairage principal canal 1 Allumez l éclairage crépusculaire afin qu il acquiè...

Page 11: ...inutes indique que vous pouvez régler l heure L heure se règle de la même manière que la date Appuyer sur le bouton TIME DATE afin de mémoriser cette heure 5 2 Ecalairage Pour la programmation de l éclairage jour et nuit vous disposez des écrans suivants A1 Allumage du canal 1 Eclairage principal HQI A2 Extinction du canal 1 A3 Allumage du canal 2 Eclairage secondaire tube A4 Extinction du canal 2...

Page 12: ...e AB Aqua Medic GmbH assure une garantie de 12 mois à partir de la date de l achat sur tous les défauts de matériaux et d assemblage de l appareil Elle ne couvre pas les pièces d usure comme le tube UV C ou la gaine de quartz Le ticket de caisse original sert de preuve d achat Durant cette période l appareil est remis gratuitement en état par échange de pièces neuves ou rénovées hors frais de tran...