background image

  5

introduction

This manual provides factory prescribed procedures for the cor-

rect service and repair of the Aqua Lung or Apeks regulator prod-

ucts described in this manual. It is not intended to be used as 

an instructional manual for untrained personnel. The procedures 

outlined within this manual are to be performed only by personnel 

who have received factory Authorized training through an Aqua 

Lung service & Repair seminar. If you do not completely under-

stand all of the procedures outlined in this manual, contact Aqua 

Lung to speak directly with a Technical Advisor before proceeding 

any further.

Scheduled Service

If the regulator is subjected to less than 50 dives per year, it is  

permissible to overhaul it every other year with an inspection  

procedure being performed on the “off” years. for example:
Year #1: Inspection
Year #2: overhaul
Year #3: Inspection
Year #4: overhaul, and so on.
both Inspections and overhauls need to be documented in the 

Annual service & Inspection Record in the back of the owner’s 

manual to keep the Limited Lifetime warranty in effect. If a 

regulator is subjected to more than 50 dives per year, it should 

receive the complete overhaul.

An Official Inspection consists of:

1.  A pressurized immersion test of the entire unit to check     

     for air leakage.
2.  checking for stable intermediate pressure that is within   

      the acceptable range.
3.  checking for opening effort that is within the acceptable  

     range.

4.  A visual inspection of the filter for debris or discoloration.

5.  A visual inspection of the exhaust valve to see that it is in     

     good shape and that it’s resting against a clean surface.
6.  A visual inspection of the mouthpiece looking for tears  

     or holes.
7.  checking that the hoses are secure in the hose clamps.

If a regulator fails item #1, 2, 3 or 4,  the entire regulator should 

be overhauled. If a regulator fails 5, 6 or 7, it will be up to the 

technician’s discretion whether or not a full overhaul is required.

general guidelines

1.  In order to correctly perform the procedures outlined in 

this manual, it is important to follow each step exactly in the 

order given.  Read over the entire manual to become familiar 

with all procedures before attempting to disassemble the 

product in this manual, and to learn which specialty tools and 

replacement parts will be required.  Keep the manual open 

beside you for reference while performing each procedure. 

do not rely on memory.
2.  All service and repair should be carried out in a work area  

specifically set up and equipped for the task. Adequate light

-

ing, cleanliness, and easy access to all required tools are 

essential for an efficient repair facility.

3.  As the regulator is disassembled, reusable components 

should be segregated and not allowed to intermix with 

nonreusable parts or parts from other units.  delicate parts, 

including inlet fittings and crowns which contain critical seal

-

ing surfaces, must be protected and isolated from other parts 

to prevent damage during the cleaning procedure.

general guidelines (continued)

4.  use only genuine Aqua Lung parts provided in the over-

haul parts kit for this product. do NoT attempt to substitute 

an Aqua Lung part with another manufacturer’s, regardless 

of any similarity in shape or size.  
5.  do not attempt to reuse mandatory replacement parts 

under any circumstances, regardless of the amount of use 

the product has received since it was manufactured or last 

serviced.
6.  when reassembling, it is important to follow every torque  

specification prescribed in this manual, using a calibrated 

torque wrench. most parts are made of either marine brass 

or plastic, and can be permanently damaged by undue 

stress.

general Conventions

unless otherwise instructed, the following terminology and tech-

niques are assumed:

1.  when instructed to 

remove

unscrew

, or 

loosen 

a thread-  

     ed part, turn the part counterclockwise.
2.  when instructed to 

install

screw in, 

or

 tighten

 a threaded   

     part, turn the part clockwise.
3.  when instructed to 

remove

 an o-ring, use the pinch                

     method (see illustration below) if possible, or use a brass    

    or plastic o-ring removal tool. Avoid using hardened steel  

    picks, as they may damage the o-ring sealing surface. All  

    o-rings that are removed are discarded and replaced with  

    brand new o-rings.

 

4.  The following acronyms are used throughout the manual:  

     

Mp

 is medium Pressure; 

hp

 is high Pressure; 

Lp

 is Low  

     Pressure.
5.  Numbers in parentheses reference the key numbers on  

     the exploded parts schematics. 

For example

, in the        

     statement, “...remove the o-ring (7) from the crown (8)...”,  

     the number 7 is the key number to the crown o-ring.

Pinch method

Press upwards on sides of o-ring to 

create a protrusion. Grab o-ring or  

insert o-ring tool at protrusion. 

Summary of Contents for MenTOR

Page 1: ...Technical Manual MENTOR PN 108568 Rev 11 10...

Page 2: ...mail at rbedard aqualung com dsumian aqualung com dstancil aqualung com Trademark Notice Aqua Lung America is a registered trademark of Aqua Lung America Inc A Note is used to emphasize important poi...

Page 3: ...7 First Stage Disassembly 8 REASSEMBLY PROCEDURE 9 Table 1 Troubleshooting Guide 15 Table 2 List of Tools and Service Kit 16 17 Table 3 Torque Specifications 17 Table 4 Bench Test Specifications 17 T...

Page 4: ...4 MENTOR Technical Maintenance Manual Change No Date Title or Description Change made by CHANGE RECORD...

Page 5: ...o learn which specialty tools and replacement parts will be required Keep the manual open beside you for reference while performing each procedure Do not rely on memory 2 All service and repair should...

Page 6: ...eplaced during a standard overhaul service 2 Unscrew the connector ring 4 on each side of the mouthpiece and separate the mouthpiece body 8 from the hoses With a small slotted screwdriver remove each...

Page 7: ...counterclockwise to remove the nut Remove the washer 24 located underneath the retaining nut 4 Separate the regulator assembly from the inhalation box Carefully inspect the inhalation box for dents or...

Page 8: ...does occur the spring block must be replaced 5 Using the extraction tool PN 109437 insert the wire end through the crown orifice engage the pin support 32 and push out the diaphragm 31b 3 Attach the v...

Page 9: ...the way into place 2 Install a new backup ring 60 into the HP spring block 61 followed by a new lubricated o ring 59 3 Install the HP seat 57 into the first stage body followed by the long seat spring...

Page 10: ...body in a vise using a vise mounting tool Using a 28mm socket attached to a ft lb torque wrench tighten the spring retainer to 25 2 ft lbs 10 Place the friction washer 27 atop the spring Thread the ad...

Page 11: ...ever legs are over the flat side of the lever support lever feet under washer 16 Using a 1 4 nutdriver tighten the locknut until three full threads are showing 17 Secure the lever support to the body...

Page 12: ...ng 42 into the regulator body 47 Pass the regulator body through the front of the inhalation box 25 The hole in the inhalation box is keyed so the body will only go in one way 2 Place the washer 24 ov...

Page 13: ...ainst the concave side Firmly press on the center of the valve until the barb is all the way through the hole Visually inspect the barb to make sure it is completely through the hole 3 Install a new l...

Page 14: ...de the lip shield 14 into place 10 Install the neck strap 15 through the buckles on each side of the mouthpiece as shown in the picture 11 Attach the regulator to a cylinder with the rubber hoses comi...

Page 15: ...hragm 31 is worn or damaged 1 Replace diaphragm 2 Diaphragm sealing area is damaged 2 Replace body 3 Port plug o rings 44 46 are worn or damaged 3 Replace o rings Second Stage Leaks 1 HP leaks 1 See H...

Page 16: ...r torque 111000 Assembly of HP components N A Assembly of HP components 944022 Removing and installation of o rings 111100 Removing circlip 5 109437 Crown 14 assembly disassembly 5116230 For holding f...

Page 17: ...SCRIPTION APPLICATION N A Second Stage disassembly reassembly adjusting N A Various N A Cleaning inside of corrugated hoses 7 0543 Clamp Installation Tool Hose clamps 7 0550 Nut Spanner Tool Body reta...

Page 18: ...stainless steel and brass parts Household grade Liquid dishwashing detergent diluted with warm water Degreaser for brass and stainless steel parts general cleaning solution for plastic and rubber Hous...

Page 19: ...to scrub away any deposits Rinse in fresh water and thoroughly blow dry using low pressure filtered air CAUTION Do not place plastic and rubber parts in acid solutions Doing so may alter the physical...

Page 20: ...nector 12 104913 Clamp 25 24 23 22 21 20 3 4 5 6 7 1 2 1 2 9 10 7 11 6 4 3 8 12 13 14 15 17 16 1 18 2 19 18 19 1 2 Key Part Description 13 101037 Mouthpiece Assembly 14 101034 Lip Cover 15 101245 Stra...

Page 21: ...ing 43 122237 HP Port Plug 44 820072 O ring 45 122233 MP Port Plug 46 820011 O ring 47 716011 Mentor Body 48 716032 O ring 49 716031 Adjustable Nozzle 50 106843 Yoke 51 124555 Dust Cap 52 107507 Yoke...

Page 22: ...22 MENTOR Technical Maintenance Manual Maintenance Notes...

Page 23: ...ES SOME STATES DO NOT ALLOW EXCLUSIONS OF LIABILITY SO THIS MAY NOT APPLY TO YOU Restrictions The following restrictions apply to this warranty This warranty extends to inflator parts and to the seams...

Page 24: ...MENTOR TECHNICAL MANUAL 2340 Cousteau Court Vista CA 92081 Phone 760 597 5000 FAX 760 597 4900 www aqualung com militaryandprofessional 2010 Aqua Lung USA Literature PN 108568 Rev 11 10...

Reviews: