![Aqua Lung LEGEND LUX Service Manual Download Page 9](http://html1.mh-extra.com/html/aqua-lung/legend-lux/legend-lux_service-manual_2958545009.webp)
Legend LX LUX second stage service manual
Service Manual Legend LX – LUX second stage
Rev. 12/2011
9
21. Remove both o-rings from the adjusting screws
22.
END OF DISASSEMBLY
Before starting to re-assemble
the regulator, make sure that all
replacement parts have been
cleaned and lubricated in
accordance with Procedure A :
Cleaning and Lubricating on
page 21
.
CLEANING OF THE VALVE SPINDLE
129626
The over-molded Valve Spindle 129626 must
be cleaned using the NETALU (or OAKITE)
diluted at 25% in an ultrasonic bath at 40°C for
5 minutes.
The over-molded Valve Spindle 129626 must
NOT be cleaned with other products.
Lift the exhaust valve and check that its surface is
clean and free of scratches. It should be flexible and its
edges should be clean. If it is in good condition it is not
necessary to remove it and it can be re-used. If there
are any signs of deterioration it should be replaced