EBIS - 3000 & 4500 User's Manual
Filling with a Compressor Fill Adapter
NOTE: The EBIS system does not include a compressor fill adapter. This
adapter (PN M100656) may be purchased separately
(Fig. 10).
O-Ring
O-Ring
Figure 10
CAUTION:
Do not attempt to fill the EBIS directly from a compressed
air filling station unless you have received the necessary training and
authorization to do so. If done incorrectly, this procedure poses certain
hazards which may cause severe injury or death.
CAUTION:
The dial pressure gauge is for reference only. Use the fill
system gauge to indicate accurate cylinder pressure.
WARNING:
DO NOT attempt to use the compressor fill adapter to fill the
EBIS from a compressor or air supply where the regulated pressure exceeds
3000 PSI (207 BAR). Doing so could cause a dangerous malfunction to the
fill adapter or weaken the cylinder and safety plug, resulting in serious
injury or death.