background image

4   

LPIS / DSIS Technical Manual

Pinch Method

Press upwards on sides of o-ring to 

create a protrusion. Grab o-ring or  

insert o-ring tool at protrusion. 

Introduction

This manual provides factory prescribed procedures for the 

correct service and repair of the Aqua Lung product described 

in this manual. It is not intended to be used as an instructional 

manual for untrained personnel.
The procedures outlined within this manual are to be performed 

only by personnel who have received Factory Authorized training 

through an Aqua Lung Service & Repair Seminar. If you do not 

completely understand all of the procedures outlined in this manual, 

contact Aqua Lung® to speak directly with a Technical Adviser 

before proceeding any further.

Scheduled Service

This product should be given the same care and maintenance 

as life support equipment. It is therefore important to perform 

scheduled overhaul service for the complete unit, according to 

the procedures outlined in this manual on a regularly scheduled 

basis; 

annually

 with normal use. Overhaul service may need 

to be performed more frequently depending on the amount of 

use it received and environmental condition in which it is used.

General Guidelines

1.

 In order to correctly perform the procedures outlined in 

this manual, it is important to follow each step exactly in the 

order given. Read over the entire manual to become familiar 

with all procedures before attempting to disassemble the 

product in this manual and to learn which specialty tools and 

replacement parts will be required. Keep the manual open 

beside you for reference while performing each procedure. 

Do not rely on memory.

2

. All service and repair should be carried out in a work area 

specifically set up and equipped for the task. Adequate lighting, 

cleanliness and easy access to all required tools are essential 

for an efficient repair facility.

3.

 As each unit is disassembled, reusable components should 

be segregated and not allowed to intermix with nonreusable 

parts or parts from other units. Delicate parts, including inlet 

fittings and crowns which contain critical seating surfaces, 

must be protected and isolated from other parts to prevent 

damage during the cleaning procedure.

4.

 Use only genuine Aqua Lung® parts provided in the 

overhaul parts kit for this product. DO NOT attempt to 

substitute an Aqua Lung® part with another manufacturer’s 

regardless of any similarity in shape or size.

5.

 Do not attempt to reuse mandatory replacement parts under 

any circumstances, regardless of the amount of use the product 

has received since it was manufactured or last serviced.

6.

 When reassembling, it is important to follow every torque 

specification  prescribed  in  this  manual,  using  a  calibrated 

torque wrench. Most parts are made of either marine brass or 

plastic and can be permanently damaged by excessive stress.

General Conventions

Unless otherwise instructed, the following terminology and 

techniques are assumed:

1.

 When instructed to 

remove

unscrew

, or 

loosen 

threaded part, turn the part counter-clockwise.
When instructed to 

install

screw

or

 tighten

 a threaded part, 

turn the part clockwise.

2.

 When instructed to 

“OPEN”

 the handwheel, turn the 

handwheel counter-clockwise. The 

red indicator ring will 

not be visible

 in the handwheel window, this indicates the 

unit is in the 

“ON”

 position.

When instructed to 

“CLOSE”

 the handwheel, turn the 

handwheel clockwise. The 

red indicator ring will be 

visible

 in the handwheel window, this indicates the unit 

is in the 

“OFF”

 position.

3. 

When instructed to depressurize the system, close 

the handwheel and connect the MP hose to an inflation 

device. Depress the inflator button on the device for 5 

seconds and release for 5 seconds. Repeat this procedure 

until the system is depressurized. Remove MP hose from 

inflation device when done.

4.

  When  instructed  to  fill  or  refill  the  cylinder,  3000  PSI 

(207 BAR) will be the standard fill pressure used for testing 

purposes in this manual. Upon completion of all testing, fill 

the cylinder to its full capacity as marked. (

Reference the 

Filling Procedures section of the User’s Manual).
5.

 The following acronyms are used throughout this manual: 

MP is 

Medium Pressure; 

HP 

is High Pressure: 

LP

 is Low 

Pressure.

6.

 Numbers in parentheses reference the key numbers on the 

exploded view parts schematics. 

For example

,

 

in the state-

ment, “...remove the o-ring (7) from the crown (8)...”, the num-

ber 7 is the key number to the crown o-ring.

7.

 When instructed to remove an o-ring, use the pinch method  

(see illustration below) if possible, or use a brass or plastic 

o-ring removal tool. Avoid using hardened steel picks, as they 

may damage the o-ring sealing surface. All o-rings that are 

removed are discarded and replaced with brand new o-rings. 

Summary of Contents for DSIS

Page 1: ...Rev 6 17 TECHNICAL MANUAL LOW PRESSURE INFLATION SYSTEM LPIS DRY SUIT INFLATION SYSTEM DSIS...

Page 2: ...to information provided in warnings cautions and notes that are accompanied by one of these symbols Trademark Notice Aqua Lung is a registered trademark of Aqua Lung America Inc 2017 AQUA LUNG AMERIC...

Page 3: ...inal Testing Procedure 12 Table 1 Troubleshooting Guide 13 Table 2 List of Tools and Service Kits 14 Table 3 Torque Specifications 17 Table 4 Test Bench Specifications 17 Table 5 Recommended Cleaners...

Page 4: ...erhaul parts kit for this product DO NOT attempt to substitute an Aqua Lung part with another manufacturer s regardless of any similarity in shape or size 5 Do not attempt to reuse mandatory replaceme...

Page 5: ...lug 17d CAUTION The relief valve screw 17a is under spring tension Use caution when disassembling CAUTION Use only brass o ring removal tools when removing o rings to prevent damaging critical sealing...

Page 6: ...ting surface 15 Remove the pressure gauge 38 using a 7 8 crowfoot and flex wrench Remove o ring 35 from the pressure gauge 10 Using the 3 4 socket and flex wrench unscrew the bonnet 24 from the first...

Page 7: ...e spring 7 from the first stage body 32 20 Insert the pins on the adjustable spanner wrench into the two holes on top of the retainer cap 2 Unscrew the retainer cap from the first stage body 32 19 Usi...

Page 8: ...e and could result in serious injury or death NOTE Certain cylinders 39 will require hydro static re testing every 5 years For more information reference Aqua Lung Technical Bulletin Hydro Testing 09...

Page 9: ...alue of 90 in lbs 10 2 Nm 11 In the following order place a new Teflon washer 29 brass washer 28 o ring 27 and back up ring 26 onto the stem 30 9 Install o ring 35 onto the pressure gauge 38 Screw the...

Page 10: ...0 so it sits on top of the bonnet 24 Face the round edge on the indicator ring 23 outward and thread the indicator ring onto the bonnet until it bottoms out 16 When the indicator ring 23 bottoms out t...

Page 11: ...nd MP hose assembly from the first stage Remove the QD adapter and test gauge from the MP hose after testing has been completed 26 Pass the threaded end of the swivel relief plug assembly 17 through t...

Page 12: ...bleshooting Guide section of this manual to determine its possible cause If no leak is detected finish filling the cylinder 39 and remove the SCUBA fill adapter from the fill port 36 5 Ensure the blee...

Page 13: ...r damaged 3 Replace retainer cap 2 4 The piston shaft o ring sealing surface in the first stage body 32 is worn or damaged 4 Replace first stage body 32 5 Swivel relief plug o rings 14 15 are worn or...

Page 14: ...SIS and SEA MK LV2 108361 Tool Pouch SEA MK Carrying Tools 111610 Test Gauge 0 400 psi Checking medium pressure 108357 Repair Mat Service and maintenance 108362 Soft Cases MP Test Gauge Cover for MP T...

Page 15: ...of First Stage Body 32 103045 Flex Wrench 3 8 Drive Removal Installation of parts FC38A 9 43628 1 3 16 Crowfoot 7 8 Crowfoot Removal Installation of First Stage Body 32 Removal Installation of Pressur...

Page 16: ...l Kit 769351 QD Adapter Test Gauge Adapter Use in conjunction with Test Gauge PN 111610 Not included in 108342 SEA MK Tool Kit N A Torque Wrench in lbs Apply torque to parts listed in Table 4 Torque S...

Page 17: ...LEANER APPLICATION SOURCE Christo Lube MCG 111 All o rings Aqua Lung PN 820466 or Lubrication Technologies 310 Morton Street Jackson OH 45640 800 477 8704 Oakite 31 Acid bath for reusable stainless st...

Page 18: ...arm water mixed with mild dish soap Use only a soft nylon toothbrush to scrub away any deposits Rinse in fresh water and thoroughly blow dry using low pressure filtered air Cleaning Hoses 1 Hose fitti...

Page 19: ...t Stage 33 820316P O ring 10 pk 34 108307 Cap Fill Port 35 820319P O ring 10 pk 36 108308 Port Fill 37 108309 Pin Fill Port 38 102810 Pressure Gauge 3000 psi Black 39 079108 Cylinder 3 0 ft Black AL 0...

Page 20: ...20 LPIS DSIS Technical Manual MAINTENANCE NOTES...

Page 21: ...21 MAINTENANCE NOTES...

Page 22: ...22 LPIS DSIS Technical Manual MAINTENANCE NOTES...

Page 23: ...23 MAINTENANCE NOTES...

Page 24: ...7 Aqua Lung International LOW PRESSURE INFLATION SYSTEM LPIS DRY SUIT INFLATION SYSTEM DSIS 2340 Cousteau Court Vista CA 92081 Phone 760 597 5000 Fax 760 597 4900 www aqualung com militaryandprofessio...

Reviews: