First Stage
PART #
DESCRIPTION / KEY ITEM #
TORQUE
AP1407
AP1471
Yoke Connector (32)
DIN Handwheel Connector (34)
14.7 ft-lbs (20 Nm)
AP1486
Turret Retaining Bolt (15)
70 in-lbs (8 Nm)
AP0203
AP1408
AP1487
AP1413
MP Hose
Blanking Plugs (9, 18, 19)
40 in-lbs (4.5 Nm)
First Stage
TEST
CONDITION
SPECIFICATION
Leak Test
Inlet 2500 - 3000 psig (206 bar)
No leaks allowed
MP
Inlet 2500 - 3000 psig (206 bar)
130 - 145 psi (9-10 bar)
MP Creep
Inlet 2500 - 3000 psig
5 psi (0.25 bar) max for 15 seconds
after cycling (purging) regulator
Second Stage
PART #
DESCRIPTION / KEY ITEM #
TORQUE
AP5002
Heat Exchanger (2)
26.6 in-lbs (3 Nm)
AP0203
MP Hose
45 in-lbs (5 Nm)
Table 4: Torque Specifications
Second Stage
TEST
CONDITION
SPECIFICATION
Leak Test
Inlet 2500 - 3000 psig (206 bar)
No leaks allowed
MP
Inlet 2500 - 3000 psig (206 bar)
130 - 145 psi (9-10 bar)
Opening Effort
Inlet 2500 - 3000 psig
MP 130 - 145 psi (9-10 bar)
+ 1.0 - 1.5 H20 (2.5 - 3.7 mbar)
Table 5: Test Bench Specifications
25