© 2008 Aqua-Hot
®
450-DE/DM Hydronic Heating System Installation Manual
— Page C-2 —
Appendix C: Electronic Controller Features
“Low Voltage Reset” Feature:
Whenever the Aqua-Hot’s DC power is interrupted, the “low
voltage reset” red indicator light on the electronic controller will
illuminate. Reset the electronic controller by pressing the “low
voltage reset” button on the electronic controller (use a thin,
straight, nonmetallic object to access the button through the
faceplate) or by turning OFF the diesel-burner switch on the
interior switch panel for approximately 30 seconds, then turning
the switch back ON.
Reset Button
(Secondary
Power Source)
12 Volt-DC Screw
Terminal
(Primary
Power Source)
12 Volt-DC Screw
Terminal
Ground Wire
Screw Terminal
Header
Terminal Strip/Plug
Pin Jumper
J4
J1
J3
J2
1
1
1
1
Electronic Controller Board
To Motorhome
From Hydronic Heating
System Wiring Harness
Wire
Loom
Wire
Loom
Wire
Loom
Wire
Loom