375-D Hydronic Heating System Installation Manual Rev. A
NOTE:
Please note that a return-air register may not be re-
quired; however, adequate return-air must be provided
to each particular heat exchanger. This means that the
total cross-sectional area of the return-air opening must
be equal to or greater than the cross-sectional area of
the hot-air outlet opening of the heat exchanger.
section 3: Hydronic Heating system
Living Room
Heat Exchanger
Living Room
Heat Exchanger
Kitchen
Heat Exchanger
Bathroom
Heat Exchanger
Fresh Water
Tank Heat
Exchanger
Aqua-Hot 375-D
Heating System
Heating Loop 1
Kitchen and Living Room
Heating Zone
Heating Loop 2
Bathroom, Bedroom,
and Fresh Water Tank Bay
Heating Zones
Bedroom
Heat Exchanger
Generalized Motorhome Heating System Floor Plan
Figure 17
Mounting the Heat Exchangers:
1.
Cut out a 2.5”H x 10”W opening for each heat ex-
changer outlet and cold-air return register. Reference
Figure 15.
2.
Mount each heat exchanger permanently into place.
3.
Install the hot-air outlet and cold-air return registers.
Reference Figure 15.
Figure 16
HEAT
EXCHANGER
HOT-AIR
OUTLET
BASE-BOARD / TOE-KICK AREA
CABINET/COUCH
REGISTER
COLD-AIR
REGISTER
REGISTER
Figure 15
Summary of Contents for 375D
Page 1: ...2008 Aqua Hot Heating Systems Inc Installation Manual...
Page 38: ...Wiring Diagram Appendix A...
Page 40: ...Wire Gauge Information Appendix B...
Page 42: ...Antifreeze Types Appendix C...
Page 44: ...Antifreeze Mixture Water Quality Recommendations Appendix D...
Page 46: ...Antifreeze Terms and Mixture Ratio Appendix E...