TROUBLESHOOTING 

 

PROBLEM

 

POSSIBLE CAUSE

 

SOLUTION

 

Power cord not plugged in 

Plug in power cord 

Power supply is OFF 

Turn power supply ON 
and/or  replace fuse  

Air switch is OFF 

Depress the air button 

Residential Current Device  
(RCD) tripped 

Unplug power cord, reset 
RCD, check power in 
receptacle and plug in 
power cord 

Pump Does Not Run 

Motor over heats 

Let the motor cool down 

Air tube disconnected 

Connect tube to air switch 
and air button nipples, 
secure 

Air tube damage/leaks 

Replace tube 

Air tube kinked 

Remove kink and properly 
route the tube 

Air button damaged 

Replace air button 

Pump Still Does Not Run, 
Even After Performing #1 

Air switch damaged 

Replace air switch 

Closed valves 

Open valves 

Low water level in spa bath 

Fill spa bath up to the 
normal bath water level 

Airlock in the plumbing 

Bleed air from plumbing 

Pump Runs But Low or No 
Water Pressure on Jets 

Clogged or blocked 
plumbing 

Open air-venturi control 
valve to release air trapped 
in plumbing 