In contrast, the “Data log” may be used to selectively and permanently store data
from all connected Aqua Computer devices and hardware data supplied by the
background service. Logged data can then be analyzed by creating charts or be
exported to files. Data is only logged while the aquasuite software is being execut-
ed.

8.1.

8.1.

8.1.

8.1. Log settings

Log settings

Log settings

Log settings

The log settings can be accessed by clicking the “Log settings” element
below the “Data log” headline in the listing. To log data, create a new
log data set by clicking the plus symbol in the upper right corner of the

settings window. Enter name, time interval and configure automatic deletion of old
data to meet your requirements. You may then add the data sources to log by
clicking the plus symbol in the “Data sources” window section. You may add an
unlimited number of data sources to each log data set, the total number of log
data sets is also unlimited.

8.2.

8.2.

8.2.

8.2. Analyze data

Analyze data

Analyze data

Analyze data

Logged data can be visually evaluated as charts. To do so, select “Ana-
lyze data” below the “Data log” headline in the listing. The chart will ini-
tially be empty, directly below the chart are eight buttons to modify the

chart. In the lower section of the window, the chart data can be configured.
To add data to the chart, first select the “Data sources” tab in the chart configura-
tion and select a data set to be displayed. If no data sources are available, you
will have to configure the log settings as described in the chapter “Log settings” of
this manual. Select the time period to be displayed on the right side of the window
and add the data to the chart by clicking the “Add data to chart” button. Repeat
this procedure if you want to display more than one data set in the chart. 
You may modify the chart using the “Chart setup” and “Data series setup” tabs.
Finally, you can use the “Chart manager” tab to save the current chart configura-
tion and to load or delete previously saved configurations. All saved chart configu-
rations will be available on overview pages for the “Log data chart” element. 
The currently displayed chart can be edited by using the buttons directly below the
chart and may also be saved as an image file. The button corresponding to the
currently selected function is highlighted by an orange frame. Please refer to the
following list for details on each function:

To save the currently displayed chart as  an  image file, click the floppy
disk symbol and select a name and location in the following dialog. 

This function can be used to add horizontal lines to the chart. While this
function is activated, simply click into the chart to add a line at the current
cursor position.

- 10 -

Aqua Computer GmbH & Co. KG

© 2019-2020

Gelliehäuser Str. 1, 37130 Gleichen

computer

aqua

Summary of Contents for farbwerk nano

Page 1: ...and installation manual farbwerk nano aquasuite version X 17 Current as of April 2020 All information contained in this manual is subject to change without prior notice All rights reserved 2019 2020 A...

Page 2: ...nd activating edit mode 7 7 3 Adding new elements 7 7 4 Editing existing elements 8 7 5 Values and names 8 7 6 Detailed data elements 8 7 7 Log data chart 8 7 8 User defined Images text drawing elemen...

Page 3: ...tion start up 20 15 5 Service administration 20 15 6 Audio and video 20 15 7 Updates and update service 20 16 Technical details and care instructions 21 16 1 Technical details 21 16 2 Care instruction...

Page 4: ...ernal version product code 53280 One USB cable with female header replacement part no 53215 External version product code 53281 One USB cable with type A connec tor replacement part no 53261 Four blac...

Page 5: ...fly Toggle strip on off by pressing the button briefly By briefly pressing the button the connected strip can be switched on or off 5 2 5 2 5 2 5 2 Adjust strip brightness by holding the button Adjust...

Page 6: ...on Basic operation Basic operation Basic operation The program window is divided into two main areas On the left side a list of overview pages data quick view data logger device pages aquasuite web an...

Page 7: ...lying desktop symbols If a overview page is unlocked for editing while desktop mode is active the page will be displayed in the aquasuite window for editing and the current desktop will be displayed a...

Page 8: ...ilable Headline only Compact display as a headline Text Displays the numerical value in a box with a headline Bar graph Displays numerical value as well as bar graph Chart Displays the value in chrono...

Page 9: ...export individual elements select the element or elements perform a right click and select Export selected from the context menu For import right click a free spot of the page and select Import page...

Page 10: ...n be configured To add data to the chart first select the Data sources tab in the chart configura tion and select a data set to be displayed If no data sources are available you will have to configure...

Page 11: ...XML file To do so select Analyze data below the Data log headline in the listing Select the Data sources tab in the chart configuration and select a data set to be exported If no data sources are ava...

Page 12: ...d This service supplies various data from PC components and imported data from aquasuite web additionally sensor data provided by third par ty software can be accessed In order to access third party s...

Page 13: ...from the su perimposed list of available effects The controller name can be altered from its default as well Confirm you selection by clicking the check symbol in the lower right corner The configura...

Page 14: ...n LED controllers Multi assign LED controllers Multi assign LED controllers Select the LED controller s to be multi assigned and click the multi assign symbol to create multiple entries for the select...

Page 15: ...sktop range to evaluate for the effect Prerequisites and limitations The AMBIENTpx effect requires Microsoft Windows operating system version 8 1 or newer Screen content preventing analysis by DRM or...

Page 16: ...4 12 4 USB power supply USB power supply USB power supply USB power supply The farbwerk nano is supplied with power through the USB connection In default configuration power consumption is limited to...

Page 17: ...plus symbol in the upper right corner of the Virtual Software Sensors window Each Virtual Software Sensor al ways has an Out element which will provide the resulting sensor value In the settings dial...

Page 18: ...uasuite does not have to be running for hotkeys to be operational if desk top pages are used the aquasuite must be running Do not use key combinations for this function that are required by other appl...

Page 19: ...uter forums is provided for your convenience 14 3 14 3 14 3 14 3 Data import Data import Data import Data import To import a data set from the Aqua Computer server the access key of the data set is re...

Page 20: ...ring features of the background service can be disabled for specific categories if errors occur 15 6 15 6 15 6 15 6 Audio and video Audio and video Audio and video Audio and video The background servi...

Page 21: ...the selected device and stored on the Aqua Computer update server The key will not have to be re entered after re installation of the software or transfer of the de vice to another computer but transf...

Page 22: ...d to receive feedback For answers on frequently asked questions please also check our web site www aqua computer de You might also want to visit our forums and discuss our products with experienced mo...

Reviews: