background image

Downdraft work benches and tables

10

Problem

Probable cause

Solution

Blower fan and 

 

motor do not start

Not wired correctly

Check if the unit is plugged.

Check and correct motor wiring for supply voltage. See 

motor manufacturer’s wiring diagram. Follow wiring 

diagram.

Electrical supply 

 

circuit down

Check power supply circuit for proper voltage. Check 

 

for fuse or circuit breaker fault. Replace as necessary.

Insufficient airflow

Fan rotation backwards Proper fan rotation is clockwise from the top of the unit. 

The fan can be viewed through the back of the motor.

Access doors open 

 

or not closed tight

Check that all access doors are in place and secured.

Filter plugged

Check the filter. Clean or replace if needed.

Dust storage area 

 

overfilled or plugged

Empty and replace the dust drawer when 2/3 full.

Pulse cleaning not 

working

Compressed air 

 

not is connected

Check the compressed is connecting to the table. 

 

The pressure must be between 80-90 PSI.

Solenoids are not 

 

wired properly

Check wiring between the single shot timer 

 

and solenoids.

Defective solenoids

Check if solenoids work properly.

Single shot timer failure Check the wiring diagram and verify all wires are 

 

correctly plugged. The timer must be set at 100ms.

  10  TROUBLESHOOTING

Summary of Contents for MAXIBENCH MB-1000

Page 1: ...enance This manual is property of the owner Leave with the unit when set up and start up are complete AQC Dust Collecting Systems inc reserves the right to change design and specifications without pri...

Page 2: ...verse pulse cleaning optional 6 5 6 Hinged Side Panels optional 6 6 Start up 6 6 1 Check list 6 6 2 Start Stop procedure 7 7 Safety measures 7 7 1 Workers Staff 7 7 2 Electrical components 7 7 3 Explo...

Page 3: ...asures and maintenance instructions 2 INFORMATION ON THE DOWNDRAFT BENCH Model Serial number Delivery date Date of installation Name of customer Address Accessories Other WARNING MAXIBENCH is not desi...

Page 4: ...d or explosion properties of combustible materials when determining the location and operation of all dust fume or mist collection equipment 4 PURPOSE AND INTENDED USE WARNING Misuse or modification o...

Page 5: ...unit The MAXIBENCH is a self contained unit and requires no special installation accommodations 5 3 Electrical connection WARNING The electrical connection must be performed by a certified electricia...

Page 6: ...mal performance it is recommended that pulsing sequences should be performed 3 times a day on tables in OFF mode Note Neglecting to pulse your filter regularly will reduce filter life 5 6 Hinged Side...

Page 7: ...the filter section 7 3 Explosive dusts If stored dusts have an explosion or flammable risk once stored in dust storage compartment an explosion relief venting system or a fire extinguishing device is...

Page 8: ...g To manually clean the filter outside the table follow these steps Open covers on the right side of the table and slide out filters Remove filter The filter should then be held at its horizontal posi...

Page 9: ...ve the aluminum sparks trap filter 3 Wash or brush away dirt in the filter Ensure you do not damage the mesh fabric 4 Proceed with a visual inspection for tears or rips Replace if necessary Put filter...

Page 10: ...an be viewed through the back of the motor Access doors open or not closed tight Check that all access doors are in place and secured Filter plugged Check the filter Clean or replace if needed Dust st...

Page 11: ...arranty customer must notify Seller in writing of the Product defect which notice shall include a reasonable description of the defect within 10 days from the date such defect is discovered or ought t...

Page 12: ...he possibility of such damages or could have reasonably foreseen them 12 3 Fire and Explosion and Acceptance of Risk Customer acknowledges that improper installation or use of the Product may result i...

Reviews: