background image

 
 

 

 

 

 

 

APX32 

  Security 

System

 

 

 

User Guide 

 

 

 
 
 
 
 

BYPASS

NO DELAY

RECORD

TEST

FUNCTION

STATUS

VOLUME

PLAY

CODE

LIGHTS ON

LIGHTS OFF

ESCAPE

SELECT

ADD

DELETE

CHIME

ARMED

READY

0

7

8

9

4

5

6

1

2

3

OFF

AW AY

STAY

AUX

 

 
 
 
 

 

 
K14115-3  11/06  Rev. A 

 

Summary of Contents for APX32

Page 1: ...curity System User Guide BYPASS NO DELAY RECORD TEST FUNCTION STATUS VOLUME PLAY CODE LIGHTS ON LIGHTS OFF ESCAPE SELECT ADD DELETE CHIME ARMED READY 0 7 8 9 4 5 6 1 2 3 OFF AWAY STAY AUX K14115 3 11...

Page 2: ...cating bus if Honeywell has not approved such device for use with your security system Use of any such unauthorized device may cause damage or compromise the performance of your security system and af...

Page 3: ...Clock Calendar 29 Scheduling User Interface 31 Remote Phone Control Feature 36 Speaker Phone Feature 38 FIRE ALARM SYSTEM 40 General Information 40 National Fire Protection Association s Smoke Detecto...

Page 4: ...4...

Page 5: ...u to manually activate fire personal emergency or silent alarms Refer to the PANIC KEYS section for detailed information Paging feature If programmed by your installer this feature alerts you to certa...

Page 6: ...activation or deactivation of X10 devices or program events e g alarm clock reminder and latch key Two way voice Allows the central station to listen talk to or conduct two way conversations with indi...

Page 7: ...stem by using the NO DELAY key in combination with the desired arming key The system also allows you to bypass selected zones before arming the system if desired Refer to the BYPASSING PROTECTION ZONE...

Page 8: ...ce or rescue departments If the Two way Voice Feature has been programmed and an alarm condition is detected the system sends an alarm message to the central station After acknowledgement is received...

Page 9: ...required if Quick Arm is active Instead press and hold down the STAY or AWAY key MESSAGE CENTER To record a message FUNCTION RECORD To stop recording before end of 85 secs OFF To play back a message...

Page 10: ...nabled by your installer OTHER FUNCTIONS To set the time and date FUNCTION 63 To set scheduling FUNCTION 64 To activate X10 devices 1 6 FUNCTION LIGHTS ON device number To activate X10 devices 7 8 FUN...

Page 11: ...ure and location of all occurrences 09002 002 V0 BYPASS NO DELAY RECORD TEST FUNCTION STATUS VOLUME PLAY CODE LIGHTS ON LIGHTS OFF ESCAPE SELECT ADD DELETE CHIME ARMED READY 0 7 8 9 4 5 6 1 2 3 OFF AW...

Page 12: ...functions and setting the real time clock Note The system functions described below are for reference only and require additional key entries to activate 1 DISPLAY WINDOW Liquid Crystal Display LCD D...

Page 13: ...protected doors windows and other perimeter protection points and sounds an alarm if one is opened Interior protection is not armed which allows movement within your house without causing an alarm En...

Page 14: ...ery condition AC Appears when AC power is present If not displayed the system is operating on backup battery power CHIME Appears when the Chime feature is activated TEST Appears when the system is in...

Page 15: ...em disarmed not ready to arm message armed away stay instant check system message NOTE The phrases shown in brackets are variable and are announced only if appropriate in the current state of the syst...

Page 16: ...exit delay at any time after arming in STAY mode This is useful if you wish to open the entry exit door to let someone in after arming the system and avoids having to disarm the system and then re arm...

Page 17: ...DELAY AWAY or STAY NO DELAY Your user code See Quick Arming paragraph Quick Arming If Quick Arm was programmed by the installer you do not need to enter the security code to arm the system Instead sim...

Page 18: ...exit alarm message is sent to the alarm monitoring company The message EA is displayed on the keypad along with a zone number indicating the faulted zone The alarm will continue to sound until the sy...

Page 19: ...ence burglary alarms OFF Your user code During alarm conditions and the entry delay the alarm panel will disarm as soon as the correct user code is entered on the keypad The entry beeps or alarm sound...

Page 20: ...passed zone number Wait for these zones to be displayed to be sure that intended zones are bypassed Arm the system as usual when the keypad displays the READY LED on steady Forced Bypass Your system m...

Page 21: ...ends an emergency message to the alarm monitoring company and sounds a loud steady alarm at your keypad and at any external sounders that may be connected ALARM plus a zone number are also displayed A...

Page 22: ...caused the alarm 101 Open system disarmed 00NN following indicates user number 102 Close system armed 00NN following indicates user number 811 Trouble 00NN following indicates the zone that caused th...

Page 23: ...n be triggered manually by pressing the AUX key on the keypad and holding it down for 4 seconds NOTE This is similar to the manual paging feature see Paging Feature for details Reminder Announcements...

Page 24: ...ding the star pound To insert a two 2 second pause press the AUX key 2 If the ESCAPE key is pressed to cancel entry the telephone number must be entered again 3 Pressing any key on a wireless RF keypa...

Page 25: ...g commands can be used to override the device activation See your installer for a full explanation of this feature To activate X10 devices 1 6 FUNCTION LIGHTS ON dev no 2 beeps To deactivate X10 devic...

Page 26: ...he end of 85 seconds Press OFF The keypad beeps twice the REC display turns off but the MESSAGE display remains on Additional messages can be recorded as long as there is recording time remaining by r...

Page 27: ...l Repeat the key sequence until the desired volume level is achieved To mute system announcements FUNCTION VOLUME OFF When muted no system announcements will be made Recorded messages will be announce...

Page 28: ...dom used but repeatable sequences Arming sequences that involve bypassing zones before arming Device activation sequences Defining the AUX Function The system must be disarmed before defining a functi...

Page 29: ...two digit hour then press ADD to accept ESCAPE to quit Hour 12 A The current hour will be displayed with the AM PM indication Enter the 2 digit hour i e 01 12 Press ADD to accept the entry and contin...

Page 30: ...1 31 Press ADD to accept the entry and continue to the year setting Press ESCAPE to back up to Month selection 6 The system will announce Enter two digit year press ADD to accept ESCAPE to quit Year 0...

Page 31: ...ot possible to enter the schedule programming mode from a wireless keypad 3 Pressing any key on a wireless RF keypad terminates Scheduling setup 4 It is not possible to enter the schedule programming...

Page 32: ...e Device Number screen Selection 1 is a time driven event that requires a begin and end time 2 Latch Key Report the user is required to enter data up to and include the End Day screen Selection 2 is a...

Page 33: ...e am A 1 end time pm P continue return to previous prompt The end hour is a two digit entry To enter the hour 3 press 0 followed by 3 The end hour 00 indicates this schedule does not have a end time P...

Page 34: ...start of window time In addition a secondary phone number must be programmed in Option 42 3 Automatic Stay Arming Will arm the system automatically and bypass any open zones at a given time It will s...

Page 35: ...ing 09 Do event on next time match every weekday will run continuously remains in schedule after executing 10 Do event on next time match every day of the weekend will run continuously remains in sche...

Page 36: ...The system is in any Test mode During real time clock setting During scheduling setup Panel is in shutdown mode programmed by your installer Panel is in Macro learning mode Remote phone control featur...

Page 37: ...code To remotely activate X10 devices 1 6 4 device no To remotely activate X10 devices 7 8 4 device no Your user code To remotely deactivate X10 devices 1 6 7 device no To remotely deactivate X10 dev...

Page 38: ...uncement is being made or a recorded message is being played back A message is being recorded If the system is in test or sniffer mode AC power is not present The speaker phone will be aborted if A re...

Page 39: ...m AUX NOTES 1 The speaker phone ringer can only be enabled disabled when the speaker phone mode is not active The system will ring once to confirm the ringer is enabled Entering VOLUME AUX a second ti...

Page 40: ...oblem go to your nearest keypad and press the single panic key or panic key pair assigned as FIRE emergency if programmed by the installer and hold down for at least 2 seconds The alarm will sound 2 E...

Page 41: ...ehold The equipment should be installed as follows A smoke detector installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each additional story of the famil...

Page 42: ...loor plan of the building Show windows doors stairs and rooftops that can be used to escape Indicate escape routes for each room Keep these routes free from obstruction and post copies of the escape r...

Page 43: ...Babysitter Code is assigned to User 07 Duress Code User 08 This feature is intended for use when you are forced to disarm or arm the system under threat When used the system will act normally but can...

Page 44: ...The display will clear when the door or window is closed Walk in front of any interior motion detectors if used and listen for three beeps and or voice descriptors if programmed The identification of...

Page 45: ...on line with the central station s remote computer The control will not operate while on line Wait a few minutes The display should disappear dI If this remains displayed for more than 1 minute the sy...

Page 46: ...ery message display will remain on as a reminder When you replace the weak battery with a fresh one the sensor will send a good battery signal to the control when the sensor is activated opening closi...

Page 47: ...y 45 secs Speaker and external piezo a SYSTEM IS IN TEST MODE b LOW BATTERY AT A TRANSMITTER c SYSTEM LOW BATTERY d FAIL TO COMMUNICATE a Opened zone identifications will appear b LOW BAT displayed wi...

Page 48: ...me Fire Alarm zone voice descriptor Fault zone voice descriptor Zones Bypassed Alarm zone voice descriptor Low Battery zone voice descriptor System Low Battery Fire Fault zone voice descriptor Chime A...

Page 49: ...erence to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures I...

Page 50: ...quipment must also be installed using an acceptable method of connection The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situation...

Page 51: ...result in the loss of your phone lines If the regular phone works correctly after the control communicator has been disconnected from the phone lines the control communicator has a problem and should...

Page 52: ...NFORMATION Your local APX Alarm dealer is the person best qualified to service your alarm system Arranging some kind of regular service program with him is advisable Your local APX Alarm dealer is Nam...

Page 53: ...X32 ______________________________________ Other Type of Alarm Burglary Fire Both Installed by Serviced by Name Name Address Address B NOTIFIES Insert B Burglary F Fire Local Sounding Device Police De...

Page 54: ...Attic Basement Living Room Dining Room Hall F BURGLARY DETECTING DEVICE LOCATIONS Front Door Basement Door Rear Door All Exterior Doors 1st Floor Windows All Windows Interior Locations All Accessible...

Page 55: ...45 CC 45 Central Monitoring Station 8 Chime 14 Chime Mode 7 9 11 21 Clock Calendar 29 30 D Day of Week Entries 35 Device Activation 5 Device Descriptions 25 Device Number 33 dI 45 Disarm 9 Disarming...

Page 56: ...Metal Hydride Battery Pack 46 Record 13 Record A Message 9 26 Remote Interactive Phone Capability 36 Restart Exit Delay 9 16 RF Jam Condition 45 S Schedule Number 32 Scheduling 31 Security Codes 6 7 4...

Page 57: ...injury or death Passive Infrared Motion Detectors can only detect intrusion within the designed ranges as diagrammed in their installation manual Passive Infrared Detectors do not provide volumetric a...

Page 58: ...R BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER EVEN IF THE LOSS OR DAMAGE...

Page 59: ...59 NOTES...

Page 60: ...60 NOTES...

Page 61: ...61 NOTES...

Page 62: ...62 NOTES...

Page 63: ...63...

Page 64: ...5132 North 300 West Provo Utah 84604 800 216 5232 www apxalarm com K14115 3I K14115 3 11 06 Rev A...