APW Wyott TBTGDL Installation And Operating Instructions Manual Download Page 2

Congratulations on your purchase of APW Wyott commercial cooking or refrigeration equipment.   APW 
Wyott takes pride in the design and quality of our products. When used as intended and with proper care 
and maintenance, you will experience years of reliable operation from this equipment.   To ensure best 
results, it is important that you read and follow the instructions in this manual carefully.

TABLE OF CONTENTS:

ITEM                                                         PAGE

ITEM                                                         PAGE

Safety Precautions

2

Preventative Maintenance Schedule

5

Owners Information

3

Cleaning

5

Warranty Information

Troubleshooting

6

Specifications

3

Parts Lists w/Exploded Views

7

Installation Instructions

4

Wiring Diagrams                                          12 

Operation

5

Warranty                                                      15

3

2

IMMEDIATELY INSPECT FOR SHIPPING DAMAGE:

All  containers  should  be  examined  for  damage  before  and  during  unloading.  The  freight  carrier  has 
assumed responsibility for its safe transit and delivery. If equipment is received damaged, either apparent 
or concealed, a claim must be made with the delivering carrier.

A)  Apparent damage or loss must be noted on the freight bill at the time of delivery. It must then be signed 
by the carrier representative (Driver). If this is not done, the carrier may refuse the claim. The carrier can 
supply the necessary forms.

B)   Concealed damage or loss if not apparent until after equipment is uncrated, a request for inspection 
must be made to the carrier within 15 days. The carrier should arrange an inspection. Be certain to hold all 
contents and packaging material.

Installation and start-up should be performed by a qualified installer who thoroughly read, understands and 
follows these instruction.

If you have questions concerning the installation, operation, maintenance or service of this product, write 
Technical Service Department APW Wyott Foodservice Equipment Company, P.O. Box 1829, Cheyenne, 
WY 82003.

 

  

 

 

 

 

!

!

WARNING: 

This symbol refers to a potential hazard or unsafe practice, which could result 

in serious injury or death.

 

  

 

 

 

 

!

!

DANGER: 

This symbol warns of imminent hazard which will result in serious injury or 

death.

 

  

 

 

 

 

!

!

CAUTION: 

This symbol refers to a potential hazard or unsafe practice, which may result in 

minor or moderate injury or product or property damage.

 

  

 

 

 

 

!

!

NOTICE: 

This symbol refers to information that needs special attention or must be fully 

understood even though not dangerous.

SAFETY PRECAUTIONS

Summary of Contents for TBTGDL

Page 1: ...roper installation operation service or maintenance can cause property damage injury or death Read and understand these instructions thoroughly before positioning installing maintaining or servicing t...

Page 2: ...the time of delivery It must then be signed by the carrier representative Driver If this is not done the carrier may refuse the claim The carrier can supply the necessary forms B Concealed damage or...

Page 3: ...ing instructions 2 Check rating label for your model designation and electrical rating General Operation Instructions 1 All foodservice equipment should be operated by trained personnel 2 Do not allow...

Page 4: ...ered once the carton is opened stop immediately and contact the freight company to file a damage claim 1 Remove all external packaging that is protecting unit 2 Remove unit from shipping container whi...

Page 5: ...exterior of the unit using a cloth with warm water NOTE ONLY USE APPROVED CLEANING SOLUTIONS i e SIZZLE 6 Place unit in operating location Make sure that the operating location is in an area where the...

Page 6: ...remove soil hard scrubbing is not necessary 5 Wet a clean towel and ring out the excess water in sink or bucket 6 Wipe platen surface with damp towel to remove left over soap sizzle and soil from plat...

Page 7: ...Dual Line Grill Gasket Bottom Panel Cover Access Bolt 1 4 20 x SS Hex Thermostat Snap Action Open 450 F Cover Plate Clip Element Element Outer 84V 543W Element Middle 69V 442W Element Inner 55V 353W...

Page 8: ...00 4881519 4881517 Plate 20 x 23 5 x I Line Grill W Assy Main Frame 1 4 20 Hex Head Gasket Connector Flex 1 2 Trade Size Conduit Flex 1 2 Tr Sz 72 Long Switch High Limit 550 F Weldment Burn Guard Scre...

Page 9: ...8 32 x1 4 Ph Pan Hd Bushing Anti Short Size 3 Connector 1 2 Flex Straight Conduit Flex 1 2 Tr Sz 42 Long NOT SHOWN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 4881520 4881534 4881521 4881529 48815...

Page 10: ...ti Short Size 3 Connector 1 2 Flex Straight 16 1 8 16 4 1 1 1 1 1 1 1 4 3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 4881507 4881546 4881551 4881557 11019 00 4881568 1486500 8133700 4881598 4881558 4881517 4...

Page 11: ...3184 88007 00 81413 00 8 32 x 3 8 Type T Pop Rivet Spacer Round Nylon Decal Ground Symbol 8 32 x 1 2 Type T 16 4 8 1 1 9 7 1 4 8 2 6 10 5 3 TBTGIL w ELECTRONIC THERMOSTATS CONTROL BOX Item P N Descrip...

Page 12: ...re Heater 1 Wire Heater 2 Wire Heater 2 Wire Heater Common Wire Heater Common Wire Relay Relay Electronic T Stat Electronic T Stat Probe 1 Probe 2 Wire Nut Ground Power Switch L2 L1 2 Probe Location 1...

Page 13: ...mit T Stat T Stat T Stat 6 39A 6 39A 6 39A 6 39A 12 78A 12 78A Gnd 5 208 Volt 2676 Watts 12 78 Amps 240 Volt 3562 Watts 14 84 Amps 1 11 3 8 4 4 11 9 10 7 2 6 543W 84V For 208V Unit 724W 97V For 240V U...

Page 14: ...14 Notes...

Page 15: ...onclusion of this warranty period portable units must be taken to or sent prepaid to the APW Wyott AuthorizedServiceAgency for in warrantyrepairs No mileageor travelcharges areallowedon portableunits...

Page 16: ...R APW WYOTT Foodservice Equipment Company 1938 Wyott Drive Cheyenne WY 82007 Phone Fax Toll Free Website E mail 1 307 634 5801 1 307 637 8071 1 800 752 0863 www apwwyott com info apwwyott com 16...