APW Wyott SEHPS Installation And Operation Instructions Manual Download Page 4

2

CLEANING

The exterior surfaces can be kept clean and attractive by regularly wiping with a clean soft cloth. Any 

discoloration can be removed with a non-abrasive cleaner.

For model SEHPS, the heating elements may be raised for access to the drip pans, which may be removed 

for cleaning and the bottom pan may be removed by sliding pan forward.

REPLACEMENT OF INFINITE CONTROL

BE SURE POWER IS DISCONNECTED BEFORE ATTEMPTING TO SERVICE UNIT.

1.   Pull control knobs on front panel forward to remove.

2.   Remove 8 screws from front panel and tilt front panel forwards.
3.   Remove the nut that mounts the inoperative control and pull the control to the side.
4.   Remove one wire at a time from the inoperative control and connect at the same terminal 

on the new control. Carefully check to see that proper wires have been connected to the 

terminals of the control. See attached wiring diagram.

5.   Assemble new control to the front panel.

MAINTENANCE AND REPAIRS

Contact the factory or one of its representatives or a local service company for service or maintenance 

if required.