background image

INSTALLATION

 

AND

 

OPERATING

 

INSTRUCTIONS

 

 

 

Thermostatic Heavy Duty Gas Griddles 

 

MODELS:

 

HTG-2424i, HTG-2436i, HTG-2448i, HTG-2460i, HTG-2472i 

(US & Canadian units are convertible and are assembled for Natural Gas) 

(European units are not convertible and assembled for the appropriate Gas) 

IMPORTANT FOR FUTURE REFERENCE 

 

Please complete this information and retain this manual for the life of the equipment. For Warranty 
Service and/or Parts, this information is required. 

 

 

Model Number 

 

Serial Number 

 

Date Purchased 

 

 
 

FOR YOUR SAFETY:

 Do not store or use gasoline or other flammable vapors and liquids 

in the vicinity of this or any other appliance. 

 

 

 

WARNING:

 Improper installation, adjustment, alteration, service or maintenance can 

cause property damage, injury or death. Read the installation, operating and maintenance 
instructions thoroughly before installing, or servicing this equipment. 

 

 

 

WARNING:

 Instructions must be posted in a prominent location. All safety precautions 

must be taken in the event the user smells gas. Safety information can be obtained from 
your local gas supplier 

 

 

                              

 

          

 

P/N 8822231  09/24/13 

APW Wyott MANUFACTURING 

DALLAS: CHEYENNE: 
1307 N. Watters Rd #180 

 Allen, TX 

 75013 

1938 Wyott Dr 

 Cheyenne, WY 

 82007 

Local: (972) 908-6100 

Local: (307) 634-5801 

Toll Free: (800) 431-2745 

Toll Free: (800) 752-0863 

Parts/Service Fax: (214) 565-0976 

Parts/Service Fax: (214) 565-0976 

 
 

Summary of Contents for HTG-2424i

Page 1: ...rs and liquids in the vicinity of this or any other appliance WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation...

Page 2: ...and liquids in the vicinity of this or any other appliance Keep the area free and clear of combustibles See ANZI Z83 14B 1991 NOTICE Instructions to be followed if anyone smells gas should be posted i...

Page 3: ...eration is fully trained and is aware of all precautions Accidents problems can result by a failure to follow fundamental rules and precautions The following words and symbols found in this manual ale...

Page 4: ...g Do not slide unit with legs mounted lift if necessary to move unit Pipe threading compound must be resistant to the action of liquefied petroleum gases Caution DO NOT use an open flame to check for...

Page 5: ...437 392 1 4 32 000 9 78 128 000 37 5 5 12 4 HTG 2460i 59 844 1520 0 24 609 6 15 437 392 1 5 32 000 9 78 160 000 46 9 5 12 4 HTG 2472i 71 844 1824 8 24 609 6 15 437 392 1 6 32 000 9 78 192 000 56 3 5...

Page 6: ...ith the front panel removed remove the plug from the manifold Place a fitting in the plug opening and connect a manometer For Natural gas the pressure in the manifold should be 5 water column or 12 4...

Page 7: ...liable ignition of the burners when the knobs are turned to HI RELIGHTING PILOT If the pilot light should go out for any reason Promptly shut off all gas at the manual shut off valve Turn off all knob...

Page 8: ...ea in which the unit is installed and will leave the unit independent of changing draft conditions All valves must be checked and lubricated periodically This must be done by an authorized service rep...

Page 9: ...ved After removal of the detergent the surface of the plate should then be covered with a thin film of oil to prevent rusting Clean stainless surfaces with a damp cloth and polish with a soft dry clot...

Page 10: ...ing into steam Food sticks to griddle Heat is set too high Griddle surface needs cleaning and or seasoning Surface under food may not have been covered with enough cooking oil Food burned around edges...

Page 11: ...t Griddle Plate 1 2 21826433 Side Firebox 2 2 2 2 2 3 21831222 Body 24 Firebox 1 21831322 Body 36 Firebox 1 21826722 Body 48 Firebox 1 21826822 Body 60 Firebox 1 21826922 Body 72 Firebox 1 4 21826017...

Page 12: ...NPT Male 4 6 8 10 12 22 2092614 Elbow 3 8c x 3 8 27 Brass 2 3 4 5 6 23 2425310 Pan Grease 24 1 1 1 1 1 24 8706315 Knob Metal Cookline 272 D Shaft 2 3 4 5 6 25 1018064 Insulation Thermostat Bulb 2 3 4...

Page 13: ...21826722 Body 48 Firebox 1 21826822 Body 60 Firebox 1 21826922 Body 72 Firebox 1 4 21826017 Support Bumer 2 21826117 Support Bumer 2 21826217 Support Bumer 2 21826317 Support Bumer 2 21826417 Support...

Page 14: ...21831346 Tube Manifold Onfice Short 1 2 3 4 5 21831246 Tube Manifold Orifice Long 1 NA NA NA NA 31 21831348 Tube Manifold Orifice Long NA 1 1 1 1 32 8834910 Decal Dial Plate T Static Griddles 2 3 4 5...

Page 15: ...Pilot Supply CE 1 21830813 Tube Pilot Supply CE 1 21831512 Tube Pilot Supply CE 1 1 60 21831317 Tube Pilot Supply CE 1 21831513 Tube Pilot Supply CE 1 21832913 Tube Pilot Supply CE 1 21833017 Tube Pil...

Page 16: ...16 NOTES...

Page 17: ...e conclusion of this warranty period portable units must be taken to or sent prepaid to the APW Wyott Authorized Service Agency for in warranty repairs No mileage or travel charges are allowed on port...

Reviews: