GGT-36H SPECIFICATIONS
Griddle Surface Dimensions
Width: 35 13/16”/910mm
Depth: 19 1/2”/496mm
4. LIGHTING INSTRUCTIONS
Lighting Instructions
Pilot Safety Valve Lighting Instructions
Standing Pilot Lighting Instructions ( NotAvailable in the European Community )
GGT Griddles are furnished with either a pilot safety valve or a standing pilot (not available in the
European Community). Please follow the instructions for your unit.
1
Turn on main gas supply to unit, on-off valve located behind the unit (not supplied with unit).
2
Turn the burner control knobs to "OFF" position. Open the front panel and wait at least 5 minutes to
allow any gas which may have accumulated in the firebox compartment to escape.
3
Depress red button on the pilot safety valve and light through observation hole in firebox. Keep red
button on pilot safety depressed for at least 1 minute after pilot has lit. If pilot does not light, repeat
this step.
4
To adjust the pilot flame, rotate knob next to the red button. Turning the knob clockwise increases
the pilot flame.Aproperly sized pilot should be 1/2" to 3/4" long (12/19 mm).
The pilot lights on the griddles have been set at the factory. A screwdriver maybe required for the
first lighting to adjust the flame for your elevation.
1
Turn off the manual shut off valve and wait 5 minutes to clear the gas.
2
Turn all knobs to the "OFF" position.
3
Remove the grease drawer and front panel for easy access.
4
Turn the manual shut off valve on.
5
Hold an ignition source (match) at the pilot tube. When the flame is established, remove the ignition
source.
6
Summary of Contents for GGT-24H
Page 14: ...Notes 14 ...