7
CLEANING / MAINTENANCE
Initial Cleaning:
Cleaning:
Extended Shutdown:
Prior to operating your new griddle, thoroughly wash the griddle surface and the exterior with a mild
detergent or soap solution. Do not use abrasive cleaners since this might damage the cabinet finish. If the
stainless steel surfaces become discolored, scrub by rubbing only in the direction of the finished grain.
1.
Always turn unit off and allow it to cool completely before cleaning. Clean thoroughly before first use.
2.
After each use, clean the griddle with wire brush or flexible spatula.
3.
Once a day, thoroughly clean splash back, sides and front. Remove the grease drawer, empty it and
wash it out.
4.
Once a week, clean the griddle surface thoroughly. If necessary, use a griddle stone, wire brush or
steel wool on the surface. Rub with the grain of the metal while the griddle is still warm. A detergent
may be used on the plate surface to help clean it; but, care must be taken to be sure the detergent is
thoroughly removed. After removal of the detergent, the surface of the plate should then be covered
with a thin film of oil to prevent rusting. Clean stainless surfaces with a damp cloth and polish with a
soft dry cloth. To remove discoloration, use a nonabrasive cleaner. After each "weekly" cleaning, the
griddle must be seasoned again. If the griddle usage is very high, the "weekly" cleaning procedures
may be done more often than once a week.
Turn the manual shutoff valve to "OFF"; (field installed valve not supplied by the manufacturer); turn all
control knobs to the "OFF" position; and shut off the pilot flame by turning the adjustment on the pilot valve.
If the griddle is to be shut down for an extended period, put a heavy coat of grease over the griddle plate.
SERVICE / REPAIR
Parts protected by the manufacturer or his agent are not to be adjusted by the installer
unless the installer is an authorized service agent.
NOTE: THISAPPLIANCE MUST ONLY BE SERVICED BYANAUTHORIZEDAGENT.
NOTE:
If you have any questions or problems contact your nearest APW/Wyott Service Representative.
CONVERSION (NotAvailable in the European Community)
Instructions are for conversion from Natural Gas to Propane (L.P.) on all models GGT and GGM.
The conversion should be done before connecting the unit to the gas supply.
1.
Remove the knobs and front panel.
2.
Remove the supply tubes that go between the valves and the orifice fittings.
3.
Remove the orifice fittings from the firebox. Change the orifices to the size recommended for
propane (L.P.).
4.
Replace the orifice fittings into the firebox.
5.
Replace the supply tubes between the valves and the orifice fittings.
6.
Replace the front panel, grease drawer and knobs.
7.
Reverse plug in pressure regulator. The marking on the plug facing out should match gas supply.
8.
Continue with the installation.