CAUTION:

  These  models  are  designed,  built,  and  sold  for  commercial  use.  If  these 

models  are  positioned  so  the  general  public  can  use  the  equipment,  make  sure  that 
cautions, warnings, and operating instructions are clearly posted near each unit so that 
anyone using the equipment will use it correctly and not injure themselves or harm the 
equipment.

 

 

  

 

 

 

 

!

!

WARNING:

 Install per the spacing requirements listed in the installation section of this 

manual. We strongly recommend having a competent professional install the equipment. 

 

  

 

 

 

 

!

!

  

 

 

 

!

!

WARNING: 

Improper  installation,  adjustment,  alteration,  service  or  maintenance  can 

cause  property  damage,  injury  or  death.  Read  the  installation,  operating  and 
maintenance instructions thoroughly before installing or servicing this equipment. 

 

WARNING:

 For your safety do not store or use gasoline or other flammable vapors and 

liquids in the vicinity of this or any other appliance. Keep the area free and clear of 
combustibles. (See ANZI Z83. 14B, 1991).

!

!

  

 

 

 

!

!

NOTICE: 

Instructions to be followed if anyone smells gas should be posted in a prominent 

place. These may be obtained from the gas supplier.

GAS PRESSURE

The appliance and it’s individual shutoff valve (to be supplied by user) must be disconnected from the gas 
supply piping system during any pressure testing of that system at test pressures in excess of ½ psi (3.45 
kPa).

The appliance must be isolated from the gas supply piping system by closing it’s individual manual shut-off 
valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ 

  

 

 

 

!

 

!

WARNING:

 A factory authorized agent should handle all maintenance and repair. Before 

doing any maintenance or repair, contact APW Wyott.

Congratulations on your purchase of APW Wyott commercial cooking or refrigeration equipment.   APW 
Wyott takes pride in the design and quality of our products. When used as intended and with proper care 
and maintenance, you will experience years of reliable operation from this equipment.   To ensure best 
results, it is important that you read and follow the instructions in this manual carefully.

TABLE OF CONTENTS:

ITEM                                                        PAGE

ITEM                                                              PAGE

Safety Precautions

3

Service/Repair

7

Specifications & Dimensions

4

Conversion

8

General Installation Instructions

9

Lighting Instructions

5

1

Operating Instructions

6

  

Cleaning/Maintenance

7

LOCATION OF DATA PLATE

The data plate is located on the right side panel.

4

GGT Calibration Procedure/Probe Location
Troubleshooting
Replacement Parts Lists & Exploded Views 

12

Warranty                                                        

16

1

2

Summary of Contents for Champion GGM-18H

Page 1: ...umber Serial Number Date Purchased Gas Griddles MODELS GGT 18H 24H 36H 48H MODELS GGM 18H 24H 36H 48H WARNING Improper installation operation service or maintenance can cause property damage injury or...

Page 2: ...al shutoff valve to be supplied by user must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of psi 3 45 kPa The appliance must...

Page 3: ...result in serious injury or death DANGER This symbol warns of imminent hazard which will result in serious injury or death CAUTION This symbol refers to a potential hazard or unsafe practice which ma...

Page 4: ...GM 36 36 915 26 661 16 3 4 426 3 25 000 7 3 75 000 22 6 10 15 25 GGM 48 48 1220 26 661 16 3 4 426 4 25 000 7 3 100 000 29 3 6 10 15 25 MODEL WIDTH IN MM DEPTH IN MM HEIGHT IN MM OF BURNERS BTU kW PER...

Page 5: ...BS 5440 PART2 BS 6891 THISAPPLIANCE MUSTBE INSTALLED INACCORDANCE WITHTHE RULES IN FORCE MUSTBE INSTALLED INAWELLVENTILATEDAREA Ventilation requirements ie B S 5440 LIGHTING INSTRUCTIONS GGT and GGM G...

Page 6: ...e unit Wherever possible avoid open windows next to the units sides or back Avoid wall type fans which create air cross currents within a room It is also necessary that sufficient air should be allowe...

Page 7: ...cleaning the griddle must be seasoned again If the griddle usage is very high the weekly cleaning procedures may be done more often than once a week Extended Shutdown Turn the manual shutoff valve to...

Page 8: ...size recommended for propane L P For units with a pilot safety valve you must also change the pilot orifice to the other pilot orifice supplied GGT Models GGM Models 4 Replace the orifice fittings int...

Page 9: ...next thermostat bulb For a 36 GGT repeat this one more time 10 to the right and for the 48 GGT repeat this twice more 10 to the right always remaining 10 5 8 from the splash guard After all locations...

Page 10: ...ded by two equals the average temperature EXAMPLE Flame extinguished 367 F Flame ignition 341 F 708 2 Average temperature 354 F If the average temperature is within 15 F of the dial marking you probab...

Page 11: ...set too high Griddle surface needs cleaning and or seasoning Surface under food may not have been covered with enough cooking oil Food burned around edges or Heat is set too high contains dark specks...

Page 12: ...12 PARTS LISTS EXPLODED VIEWS GGM GRIDDLES EXPLODED VIEW 40 22 16 17 18 5 7 8 11 21 41 32 42 23 33 43 24 44 15 25 35 45 26 36 37 48 49 20 30 50 39 2 4 34 38 3 19 29 28 27 56 12 9 10 14 46 47 1 6 31 13...

Page 13: ...218209 18 218210 18 Weldment Griddle GGM 18 Weldment Griddle GGM 24 Weldment Griddle GGM 36 Weldment Griddle GGM 48 Body 18 Firebox GGM Body 24 Firebox GGM Body 36 Firebox GGM Body 48 Firebox GGM Tub...

Page 14: ...17 42 44 67 48 1 38 28 GGT GRIDDLES EXPLODED VIEW 53 51 59 69 66 40 60 12 22 16 18 5 7 8 9 10 11 21 41 32 23 33 58 68 14 24 52 15 25 35 26 55 65 37 57 61 49 20 50 39 2 4 54 64 62 34 6 3 13 19 63 29 27...

Page 15: ...es 1 Varies 2 2 2 2 Varies 1 1 1 Varies Varies 1 1 1 1 Varies Varies 1 Varies 1 1 1 1 1 1 2 Varies Varies 1 Varies Varies 1 Varies 2 1 1 1 1 Varies 1 1 Varies 1 Varies Bags Poly 36x27x44 Insulation Th...

Page 16: ...onclusion of this warranty period portable units must be taken to or sent prepaid to the APW Wyott AuthorizedServiceAgency for in warrantyrepairs No mileageor travelcharges areallowedon portableunits...

Reviews: