WARNING: This symbol refers to a potential hazard or unsafe practice, which could result in

serious injury or death.

!

!

!

DANGER:This symbol warns of imminenthazard which will result in serious injury or death.

!

!

CAUTION: This symbol refers to a potential hazard or unsafe practice, which may result in minor or

moderateinjury or product or property damage.

!

!

NOTICE: This symbol refers to information that needs special attention or must be fully understood

even though not dangerous.

SAFETY PRECAUTIONS

Before installing and operating this equipment be sure everyone involved in its operation are fully trained

and are aware of all precautions.Accidents and problems can result by a failure to follow fundamental rules

and precautions.

The following words and symbols, found in this manual, alert you to hazards to the operator, service

personnel or the equipment.The words are defined as follows:

!

!

WARNING:This product is intended for commercialuse only. Not for householduse.

!

CAUTION: These models are designed, built, and sold for commercial use. If these models are

positioned so the general public can use the equipment make sure that cautions, warnings, and

operating instructions are clearly posted near each unit so that anyone using the equipment will

use it correctlyand not injure themselvesor harm the equipment.

!

!

!

WARNING:

-

SHOCK HAZARD Do not open any panels that require the use of tools.

!

!

NOTICE: THESE PROCEDURES MUST BE PERFORMED BY QUALIFIED PERSONNEL OR

WARRANTYWILLBE VOIDED..

!

!

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause

property damage, injury or death. Read the installation, operating and maintenance instructions

thoroughlybefore installing or servicingthis equipment.

!

!

NOTICE: The unit when installed, must be electrically grounded and comply with local codes, or in

the absence of local codes, with the national electrical code ANSI/NFPA70- latest edition.

Canadian installation must comply with CSA-STANDARD C.22.2 Number 0 M1982 General

Requirements-CanadianElectricalCode Part II, 109-M1981-CommercialCookingAppliances.

!

!

NOTICE: Local codes regarding installation vary greatly from one area to another. The National

Fire Protection Association, Inc. states in its NFPA96 latest edition that local codes are “Authority

Having Jurisdiction” when it comes to requirement for installation of equipment. Therefore,

installation should comply with all local codes.

SPECIFICATIONS

Electrical:

Dimensions Unit:

Heating Elements:

CDO-17

120 Volts, 50/60 Hz, 13 amps, 1 Phase, 1.5 KW

208/240 Volts, 50/60 Hz, 7.7/9.0 amps, 1 Phase, 1.6 KW/21.4 KW

21-3/4" W x 25" 0 x 18.75" H

Three metal sheath heaters; one over the top shelf, one under the top shelf, and one

under the bottom shelf.Athermostat is provided for selecting the desired temperature.Afifteen-minute timer

is provided for customer convenience.

!

WARNING: Check the data plate on this unit before installation. Connect the unit only to the voltage

and frequencylisted on the data plate. Connect only to 1 or 3 phase as listed on the data plate.

!

4

All manuals and user guides at all-guides.com

Summary of Contents for CDO-17

Page 1: ...TURE REFERENCE Please complete this information and retain this manual for the life of the equipment For Warranty Service and or Parts this information is required Model Number Serial Number Date Purc...

Page 2: ...ing any maintenance or repair contact APW Wyott Technical Service Department at 800 752 0863 or 307 634 5801 WARNING Never clean any electrical unit by immersing it in water Turn off before cleaning s...

Page 3: ...ions If the unit fails to operate check the following 1 Make sure the unit is connected to a live power source 2 Check the circuit breaker to be sure it has not been tripped 3 Check if the power switc...

Page 4: ...LIFIED PERSONNEL OR WARRANTY WILL BE VOIDED WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and mai...

Page 5: ...78 10 825755 01 31007 45 14044 15 81 058 00 Supplied w Heater Supplied w Heater 841 04 00 300501 10 819764 01 02 819765 10 82499 00 825366 21 825366 20 81 058 00 825043 10 14798 07 15139 03 14994 05 8...

Page 6: ...y authorized service agent for adjustment Note It requires 20 45 minutes for the oven to reach a desired temperature 3 When the indicator light goes out place the product in the oven Set the timer to...

Page 7: ...nd lift off case Item 37 3 Remove the thermostat sensor from the oven by unscrewing the mounting clips Item 42 and bending the sensor around Push it back through the hole 4 Unscrew the control panel m...

Page 8: ...ills which have in store service The following conditions are not covered by warranty Equipment failure relating to improper installation improper utility connection or supply and problems due to vent...