Troubleshooting

Error indications

Description

Probable Cause

Solution

HEATING

 

indicator light 

flashes twice 

continuously

Temperature sensor 

under the oil tank 

is either shorted-

circuited or open-

circuited. Buzzer 

alarms.

Temperature sensor 

is defective

1.  Unit overheated. 

2.  Let it cool.

Note:

 If it occurs frequently, call Apuro 

agent or qualified technician

HEATING

 

indicator light 

flashes 3 times 

continuously

Input voltage 

exceeds the allowed 

Max/Min rating

Electrical installation 

is not in order

Have a qualified electrician check it. 

HEATING

 

indicator light 

flashes 4 times 

continuously

Temperature sensor 

in the oil tank is 

either shorted-

circuited or open-

circuited. Buzzer 

alarms.

Temperature sensor 

is defective

1.  Unit overheated. 

2.  Let it cool. 

Note:

 If it occurs frequently, call Apuro 

agent or qualified technician

Fault

Probable Cause

Solution

Appliance not 

working

The unit is not switched on

Check the unit is plugged in correctly and 

switched on

Plug or lead is damaged

Replace plug or lead

Mains power supply fault

Check mains power supply

Appliance stops 

working suddenly

Safety switch is activated

Please check your machine is safe with on 

obvious damage and then press the re-set 

switch on the rear

Appliance does 

not reach set 

temperature

Faulty thermostat

Call Apuro agent or qualified technician

Faulty element

Call Apuro agent or qualified technician

Build-up of fat on the element

Clean the appliance

Appliance heats up 

but indicator light 

does not come on

Indicator light has expired

Call Apuro agent or qualified technician

Power indicator 

light comes on but 

appliance does not 

heat up

Faulty thermostat

Call Apuro agent or qualified technician

Faulty element

Call Apuro agent or qualified technician

Thermostat set incorrectly

Check and re-set the thermostat

Appliance slow to 

heat up

Build-up of fat in the tank

Clean the appliance

Oil overheats or 

starts to smoke

Thermostat damaged

Switch off immediately. Call Apuro agent or 

qualified technician

CP793-A_CT012-A_A5_v2_20211220.indb   7

CP793-A_CT012-A_A5_v2_20211220.indb   7

2021/12/20   17:22

2021/12/20   17:22

Summary of Contents for CP793-A

Page 1: ...Model CP793 A CT012 A Induction Fryer Instruction manual CP793 A_CT012 A_A5_v2_20211220 indb 1 CP793 A_CT012 A_A5_v2_20211220 indb 1 2021 12 20 17 22 2021 12 20 17 22...

Page 2: ...with jet pressure washers DO NOT move or carry the appliance when it is switched on Attended appliance and switch off after use Fire Risk Caution Never switch on the deep fryer without oil inside ALWA...

Page 3: ...ilities or lack of experience or knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety Children should be superv...

Page 4: ...g for the first time clean the lid basket batter plate and the oil tank with warm soapy water Let dry completely Operation Control panel Frying basket Lid Batter plate Drainage tap Safety switch Remov...

Page 5: ...the food is cooked Shake gently above the oil tank to remove any excess oil WARNING The food and oil are very hot Take care when removing the basket as oil may drip 7 After use set the POWER switch t...

Page 6: ...er Tap ON position Tap OFF position If the oil is to be reused then filtering it before refilling will extend the oil s cooking life Use a suitable detergent to clean the oil tank Let it dry well ensu...

Page 7: ...in correctly and switched on Plug or lead is damaged Replace plug or lead Mains power supply fault Check mains power supply Appliance stops working suddenly Safety switch is activated Please check yo...

Page 8: ...vent possible harm to human health and or the environment the product must be disposed of in an approved and environmentally safe recycling process For further information on how to dispose of this pr...

Page 9: ...andaard en Je soussign confirme la conformit de l quipement cit dans la pr sente la aux Directive s et Norme s ci dessus Ich der die Unterzeichnende erkl re hiermit dass das oben angegebene Ger t der...

Page 10: ...CP793 A_CT012 A_A5_v2_20211220 indb 10 CP793 A_CT012 A_A5_v2_20211220 indb 10 2021 12 20 17 22 2021 12 20 17 22...

Page 11: ...CP793 A_CT012 A_A5_v2_20211220 indb 11 CP793 A_CT012 A_A5_v2_20211220 indb 11 2021 12 20 17 22 2021 12 20 17 22...

Page 12: ...CP793 A_CT012 A_A5_v2_20211220 CP793 A_CT012 A_A5_v2_20211220 indb 12 CP793 A_CT012 A_A5_v2_20211220 indb 12 2021 12 20 17 22 2021 12 20 17 22...

Reviews: