aptos MAC DTU User Manual Download Page 7

7

external

 

control

 

device

 

with

 

a

 

standard

 

RJ-45

 

connector.

 

For

 

MAC

TM

 DTU

,

 

it

 

can

 

support

 

DRM0/5/6/7/8

 

if

 

used

 

with

 

Aptos

 

microinverters.

Mode

Requirement

DRM0

Operate the disconnection device

DRM1

Do not consume power

DRM2

Do not consume at more than 50% of rated power

DRM3

Do not consume at more than 75% of rated power AND Source reactive power if

capable

DRM4

Increase power consumption

(subject to constraints from other active DRMs)

DRM5

Do not generate power

DRM6

Do not generate at more than 50% of rated power

DRM7

Do not generate at more than 75% of rated power AND Sink reactive power if capable

DRM8

Increase power generation

(subject to constraints from other active DRMs)

3.5

 

Local

 

Install

 

Assistant

Local

 

Install

 

Assistant

 

is

 

a

 

new

 

function

 

integrated

 

with

 

MAC

TM

 DTU

.

 

P

lease

 

download

 

the

 

Installer

 

App

 

(for

 

installer/distributor

 

use

 

only)

 

first.

 

MAC

TM

  DTU

 

has

 

improved

 

from

 

the

 

previous

 

generation

 

of

 

DTU

 

product

s.

 

New 

functions allow installer to

:

a. One step to complete the WiFi configuration;

b. Station overall Inverters status indication allows the installer to see how many MI under

this DTU 

is

 

working

 

properly

 

(and

 

the

 

details

 

for

 

each

 

MI)

 

and

 

how

 

many

 

is

 

abnormal

 

(and

the

 

details

 

for

 

each

 

MI)

 

with

 

one

 

glance

 

of

 

eyes;

c. Add

 

the

 

Connection

 

status,

 

which

 

will

 

display

 

the

 

signal

 

strength

 

between

 

each

 

MI

 

with

connected

 

DTU,

 

so

 

that

 

installer

 

can

 

adjust

 

the

 

DTU

 

installation

 

location

 

accordingly.

 

This

function

 

will

 

simplify

 

the

 

DTU

 

installation,

 

and

 

avoid

 

a

 

second

 

visit

 

by the installler due to a

poor connection between DTU and certain MI

.

Note:

 

Please

 

refer

 

to

 

Aptos

 

Local

 

Install

 

Assistant

 

Technical

 

Note”

 

for

 

more

 

details.

©  20

21

 

Aptos Solar Technology, LLC.

  All  rights  reserved.

MAC

TM

 DTU

Summary of Contents for MAC DTU

Page 1: ...Version1 0 August2021...

Page 2: ...xport Management Function RS485 port 5 3 3 Remote Active Power Control RS485 port 6 3 4 DRM Port 6 3 5 Local Install Assistant 7 4 DTU Installation 8 4 1 System Capacity 8 4 2 Basic Conditions Require...

Page 3: ...s products in ways unspecified by manufacturer Doing so may result death injury to persons or damage to equipment 1 3 User This manual is only for professional installation and maintenance personnel t...

Page 4: ...nversion efficiency up to 96 7 and MPPT efficiency up to 99 9 Aptos microinverters rank in the first class of the world s microinverter industry 2 2 DTU The DTU is the key component in Aptos microinve...

Page 5: ...r With Server D DTU Communication Indicator With MI E DTU Alarm Indicator F WiFi Antenna 2 4G G RS485 H DRM Port For Australia only I Ethernet Port J USB Port K Reset Bottom L Power Port M 2 4G Antenn...

Page 6: ...MAC 800R MAC 800R Note Please refer to Aptos Export Management Technical Note for more details 3 3 Remote Active Power Control RS485 port Some countries require generating plants to be equipped with a...

Page 7: ...tion integrated with MACTM DTU Please download the Installer App for installer distributor use only first MACTM DTU has improved from the previous generation of DTU products New functions allow instal...

Page 8: ...en Microinverter and DTU needs to be within the required range 4 2 Basic Conditions Required Before installing the DTU ensure that the site meets the following requirements Standard 220 VAC power outl...

Page 9: ...dure 5 Normal operation 7 Add Microinverter ID 6 Login the local interface of the DTU 8 Check the Communication between Microinverters and DTU Unit mm 4 4 System Installation Sequence 4 5 Preparation...

Page 10: ...he antenna into the WiFi port and 2 4G port Note If the DTU installation location is inside the metal box or under the metal concrete roof extended 2 4G cable or 2 4G sucker antenna will be suggested...

Page 11: ...at least two screw holes one from each side to affix the bracket the M4 screws need to prepare by installer Match the brackets upper buckle with MACTM DTU Match the brackets lower buckle by gently pr...

Page 12: ...onnect one side with the house router and the other side with the DTU Ethernet port Use the smart phone tablet to open the Installer App and login Approach to Me on the bottom of the page and then Net...

Page 13: ...installer with Aptos please apply an Installer account from your distributor in advance C Add Station select the Station tab on the bottom then select on the right top side of the page D Select Quick...

Page 14: ...the Installer account L Please click the Networking button after the power station is created M Please wait about 30 minutes the station will show online and all the MI IDs are found 7 Customer Login...

Page 15: ...rs The system status can be viewed by Aptos local APP or LED indicators LED mark LED Color Explanation DTU power on or power off Network communication Microinverter communication Fault State LED State...

Page 16: ...ED LED Indicator 4 RUN Cloud MI ALM APP Local APP Power Supply Type External plug in adapter All Firmware upgrading Starting up DTU power on DTU power off DTU are communicating with Aptos Monitoring S...

Page 17: ...20 kg Mounting system Wall mounting Desktop mounting Features Compliance FCC 15B FCC 15C EN60950 1 EN61000 3 2 EN61000 3 3 EN301489 EN300328 EN300440 RCM 1 If the DTU installation location is inside...