APsystems Microinverter DS3-S User Manual

2

1. Important Safety Instructions

This manual contains important instructions to follow during installation and maintenance of

the APsystems Photovoltaic Grid-connected Microinverter. To reduce the risk of electrical

shock and ensure a safe installation and operation of the APsystems Microinverter, the

following symbols appear throughout this document to indicate dangerous conditions and

important safety instructions.

Specifications are subject to change without notice. Please ensure you are using the most

recent update found at https://emea.apsystems.com/resources/library/

This indicates a situation where failure to follow instructions may cause a serious

hardware failure or personnel danger if not applied appropriately. Use extreme caution

when performing this task.

This indicates information that is important for optimized microinverter operation.
Follow these instructions closely.

1.1 Safety Instructions

Only qualified professionals should install and/or replace APsystems Microinverters.

Perform all electrical installations in accordance with local electrical codes.

Before installing or using the APsystems Microinverter, please read all instructions and
cautionary markings in the technical documents and on the APsystems Microinverter
system and the solar array.

Do NOT disconnect the PV module from the APsystems Microinverter without first
disconnecting the AC power.

Be aware that the body of the APsystems Microinverter is the heat sink and can reach a
temperature of 80°C. To reduce risk of burns, do not touch the body of the Microinverter.

Do NOT attempt to repair the APsystems Microinverter. If the microinverter is suspected
to be faulty, please contact your local APsystems Technical Support to start
troubleshooting and obtain a RMA (Return Merchandise Authorization) number to start
the replacement process if needed. Damaging or opening the APsystems Microinverter
will void the warranty.

Caution!
When connecting a microinverter, it is recommended to first connect the AC Bus cable to
the ground then connect the AC connector to ensure proper earthing of the microinverter,
then do the DC connections. When disconnecting a microinverter disconnect the AC by
opening the branch circuit breaker first but maintain the protective earthing conductor in
the branch circuit breaker connected to the microinverter, then disconnect the DC inputs.

Please install AC breakers on the AC side of the inverter.

Draft

Summary of Contents for DS3-S

Page 1: ...User Manual All Rights Reserved ALTENERGY POWER SYSTEM Inc emea APsystems com APsystems Cypresbaan 7 2908 LT Capelle aan den Ijssel The Netherlands Tel 31 10 2582670 EMAIL info emea APsystems com APs...

Page 2: ...croinverters to the Racking 9 4 3 4 Step 4 Ground the system 10 4 3 5 Step 5 Connect the APsystems microinverter to AC bus cable 10 4 3 6 Step 6 Install a Bus Cable End Cap at the end of AC bus cable...

Page 3: ...lling or using the APsystems Microinverter please read all instructions and cautionary markings in the technical documents and on the APsystems Microinverter system and the solar array Do NOT disconne...

Page 4: ...interference in a residential installation Nonetheless if the Microinverter does cause harmful interference to radio or television reception you are encouraged to try to correct the interferences by o...

Page 5: ...tion concerning the decommissioning of equipment CE mark is attached to the solar inverter to verify that the unit follows the provisions of the European Low Voltage and EMC Directives Refer to the op...

Page 6: ...d in utility interactive grid tied applications comprised of three key elements APsystems Microinverter APsystems Energy Communication Unit ECU APsystems Energy Monitor and Analysis EMA web based moni...

Page 7: ...top performance from the array by maximizing the performance of each module individually within the array More reliable than centralized or string inverters The distributed APsystems Microinverter sy...

Page 8: ...nce waterproof properties and ensure maximum reliability of the system via rigorous testing methods including accelerated life testing A 24 7 energy access through Apps or web based portal facilitate...

Page 9: ...ms Microinverter please read all instructions and warnings in the technical documents and on the APsystems Microinverter system itself as well as on the PV array Be aware that installation of this equ...

Page 10: ...y match Improper cabling can irreparably damage the microinverters such damage is not covered by the warranty It is strictly prohibited to hand carry the microinverter by its AC cable 4 3 3 Step 3 Att...

Page 11: ...needed using the grounding lug supplied with the Microinverter Figure 3 4 3 5 Step 5 Connect the APsystems microinverter to AC bus cable Insert the microinverter AC connector into the trunk cable con...

Page 12: ...used connectors with Bus Cable Y CONN Cap to protect the unused connectors Figure 7 4 3 6 Step 6 Install a Bus Cable End Cap at the end of AC bus cable a Strip cable jacket c Insert the wires into the...

Page 13: ...his entire check function will start and end within 10 seconds of plugging in the unit so pay careful attention to these lights when connecting the DC cables Double check to make sure all of the AC an...

Page 14: ...e in the last page appendix of this manual Use ECU_APP available in the EMA Manager to scan the serial numbers on the map when setting up the ECU see ECU instruction manual for more info 4 3 9 Step 9...

Page 15: ...ower after approximately one minute of waiting time 3 Microinverter data will be available in the EMA Manager APP or in the EMA web portal Alternatively LED sequences could be an indicator of microinv...

Page 16: ...m Unless the GFDI error has been cleared the LED will remain red and the ECU will keep reporting the fault Please contact your local APsystems Technical Support 6 2 ECU_APP APsystems ECU_APP available...

Page 17: ...al Support Never disconnect the DC wire connectors under load Ensure that no current is flowing in the DC wires prior to disconnecting Always disconnect AC power before disconnecting the PV module wir...

Page 18: ...DC wire connectors from the microinverter 4 Remove the Microinverter from the PV array racking B Install a replacement Microinverter to the rack Remember to observe the flashing green LED light as soo...

Page 19: ...mpatible with the range allowed on APsystems Microinverter Please check the microinverter datasheet DC operating voltage range of the PV module must be within allowable input voltage range of the APsy...

Page 20: ...l Rating IP67 Features Communication Inverter To ECU Encrypted ZigBee Isolation Design High Frequency Transformers Galvanically Isolated Energy Management Energy Management Analysis EMA system Warrant...

Page 21: ...9 DS3 S Wiring Diagram 9 1 Sample Wiring Diagram Single Phase Figure 12 DS3 ENERGY COMMUNICATION UNIT ECU SOLAR PANEL BUS CABLE END CAP INSTALL AT THE END OF AC BUS CABLE AC JUNCTION BOX DISTRIBUTION...

Page 22: ...your PV installation Each APsystems microinverter has two serial number labels Peel the one label and affix it to the respective location on the APsystems installation map Installation Map Template I...

Reviews: