APS Chlorinators Surechlor 2500 Quick Start Manual Download Page 4

Chemical Balance Guide

Your 

Surechlor S2500

 Salt Water Chlorinator is designed to be used for swimming pool 

water, which needs to be balanced in accordance with Langlier Saturation Index, with a pH 

level of 7.2 to 7.6 and maintains the recommended levels of sanitizer. (i.e 2 - 3 ppm of free 

chlorine). Regular water analysis and advice on correct addition of chemicals and/or 

products to achieve suitable water quality and balance by a reputable professional pool shop 

will ensure bather health and comfort and extended equipment service life. 

PLEASE NOTE: Proof (i.e. hard copy) of regular water analysis by a reputable professional 

pool shop will be required as evidence of suitable water quality and balance in the event of a 

warranty claim.

Cell Maintenance Frequency

Your 

Surechlor S2500

 Salt Water Chlorinator has been designed to operate for extended 

periods of time with a minimum of maintenance. The cell cleaning function is performed 

automatically. However manual cleaning on a regular six monthly basis will enhance chlorine 

production and extended equipment service life.

Cell Cleaning

Manual Procedure

1. Remove the 

Surechlor S2500

 Salt Water Chlorinator plug from 

    240 volt power point.

2. Remove cell from plumbing.

3. Turn cell upside down (inlets facing upwards) and place on a level 

    non-metallic surface in a well ventilated area.

4. Prepare your cell cleaning solution by following the directions 

    supplied by the chemial manufacturer.

5. Carefully pour suffi cient cleaning solution into the upturned cell so 

    as to fully cover the metal electrodes.

6. Allow to stand for 10 minutes then fl ush out with clean water.

7. If electrodes still show white deposits, repeat the above steps. 

    It is recommended that a warm water detergent solution be used to soak the electrodes at 

    this point if there is any evidence of body fats, oils or grease.

8. Refi t the cell to plumbing line making sure both rubber “O” ring seals are in place.

9. Re-connect the Power Pack plug to 240 volt power point and switch on.

HANDLING ACID: Rubber gloves and protective eyewear must be worn. DO NOT put used 

acid solution into the pool.

Maintainance

Summary of Contents for Surechlor 2500

Page 1: ...increase output Press DOWN arrow to reduce output 4 Power LED Indicates if the unit is ON 5 Production LED s Displays output of unit 50 75 or 100 6 Pump outlet and Fuse holder 3 pin pump outlet to su...

Page 2: ...in direct sunlight If mounted in direct sunlight the LED indicators will be less visible The suitable location must not be attached to or on top of a source producing large amounts of heat e g metal...

Page 3: ...ne output scale or as high as prevailing conditions will allow To operate the pump and lter only without the cell simply disconnect your Surechlor S2500 Salt Water Chlorinator from power and plug the...

Page 4: ...owever manual cleaning on a regular six monthly basis will enhance chlorine production and extended equipment service life Cell Cleaning Manual Procedure 1 Remove the Surechlor S2500 Salt Water Chlori...

Page 5: ...ater Chlorinator is serviced regularly on a six monthly basis by a reputable professional serive technician Customer Responsibility Your Before You Call For Service Checklist Before calling for servic...

Page 6: ...ons The Surechlor S2500 Salt Water Chlorinator has been connected to a power supply other than 240 volt 50Hz The Surechlor S2500 Salt Water Chlorinator has been used for any purpose other than swimmin...