Product Specification
- 23 -
APRO Rugged Metal 2.5” SATA III MLC SSD – BON-II Series © 2015 APRO Co., Ltd.
5.3.7. USA-Army 380-19
Below lists the Secure Erase procedures of USA-Army 380-19.
Erase all media.
Overwrite with random data.
Fill with 0x55.
Fill with 0xAA
5.3.7.1. Inputs for Enabling USA-Army 380-19
Table 24 – Input
USA-Army 380-19
Command Code (Enable)
Register
7
6
5
4
3
2
1
0
Features
26h
Sector count
41h
LBA Low
NA
LBA Mid
NA
LBA High
NA
Device
1
1
1
0
NA
Command
82h
5.3.7.2. Outputs for Enabling USA-Army 380-19
Table 25 – Output
USA-Army 380-19
Command Code (Enable)
Register
7
6
5
4
3
2
1
0
Error
NA
Sector count
NA
LBA Low
NA
LBA Mid
NA
LBA High
NA
Device
obs
NA
obs
DEV
NA
NA
NA
NA
Status
BSY
DRDY
DF
NA
DRQ
NA
NA
ERR
Device register
DEV
- shall specify the selected device.
Status register
BSY
- will be cleared to zero indicating command completion
DRDY
- will be set to one.
DF
(Device Fault) - will be cleared to zero.
DRQ
- will be cleared to zero.
ERR
- will be cleared to zero.