Aprisma DSU IQ Manual Download Page 1

Adtran DSU/CSU

Device Management

Supports Management Module SM-ADT1000

T

itl
epa

e

Summary of Contents for DSU IQ

Page 1: ...Adtran DSU CSU Device Management Supports Management Module SM ADT1000 Titlepae...

Page 2: ...isma com manuals trademark list htm All referenced trademarks service marks and trade names identified in this document whether registered or unregistered are the intellectual property of their respec...

Page 3: ...nel Detail View 19 DEVICE TOPOLOGY VIEWS 20 Device Topology View 20 Sub Interfaces Topology View 21 DevTop Chassis View 21 APPLICATION VIEWS 22 Main Application View 22 Supported Applications 23 Commo...

Page 4: ...DBU Configuration View 47 Adtran DSU IQ Status Application AdDSUIQStatApp 49 Current Status View 49 DDS Interval Status Table View 51 DDS Daily Status Table View 51 DBU Interval Status Table View 51...

Page 5: ...Configuration View 79 Adtran TSU IQ Status Application AdTSUIQPStaApp 80 Current Status View 80 T1 Interval Status Table View 81 T1 Daily Status Table View 82 DBU Interval Status Table View 83 DBU Dai...

Page 6: ...n ATLAS Chassis Application AdATLChasApp 111 Atlas 800 Interface Table View 112 Interface Table 112 Physical Table 112 Adtran ATLAS General Option Card Application AdATLGenOCApp 113 ATLAS General Opti...

Page 7: ...monitor configure and troubleshoot Adtran devices through software models in your SPECTRUM database Information specific to SM ADT1000 is what is primarily included in this document For general inform...

Page 8: ...X 1 and V 35 DTE Interfaces 100 DLCIs supported IQ Probe Frame aware monitoring device that fits between router and existing DSU CSU Frame Relay utilizing EIA 232 V 35 EIA 530 and X 21 Interfaces DSU...

Page 9: ...ration switching and Integral 10BaseT and IP Router Supports external routers via V 35 or T1 ATLAS 550 Similar functionality to the ATLAS 800 but has six slot modular chassis Two network interface slo...

Page 10: ...Device Icon appears in Device Topology Location and Device Interface views Option Accesses the Fault Management For further information refer to How to Manage Your Network with SPECTRUM Device Device...

Page 11: ...Adtran management module is organized as follows Tasks Page 12 Device View Page 14 Device Topology Views Page 20 Application Views Page 22 Performance Views Page 119 Configuration Views Page 120 Adtr...

Page 12: ...ew Page 46 DBU Configuration View Page 47 Unit Configuration View Page 106 Network Configuration View Page 107 DBU Configuration View Page 108 ISDN DBU Configuration View Page 109 Port Configuration V...

Page 13: ...nnel Number select Port Configuration View Page 110 Telnet and Vt100 Terminal Control Password Set System Configuration Information View Page 42 Topology check Device Topology Views Page 20 TSU ESP Da...

Page 14: ...you monitor the device operation and access other device specific views Figure 2 Interface Device View SpectroGRAPH Router Device Model Name File View Help Tools Model Name Contact Description Locatio...

Page 15: ...sible label color representations Note that the color of the label also depends on the interface s current Administrative Status which you set in the Interface Configuration view This view can be acce...

Page 16: ...s and mask for the interface Interface Icon Subviews Menu Table 3 lists the device specific interface Icon Subviews menu options and the views to which they provide access Table 3 Interface Icon Subvi...

Page 17: ...is Device View Access From the Icon Subviews menu for the Atlas Device icon select Device Chassis This view provides information about the status of module and module ports and allows you to determine...

Page 18: ...llowing information Interface Number Label The number and type for this interface Interface Status Label The current status of this interface See Table 2 Interface Status Label Colors Page 15 Chassis...

Page 19: ...n Card Module Overall Status Indicates the overall status of the module Possible values are OK ONLINE TESTING DOWNLOAD FLASH_DOWNLOAD ERROR and ALARM Module LED Front Panel Detail View Access From the...

Page 20: ...present the device s serial network and I O ports These icons provide the same information and menu options as those in the Device View Page 14 If a device is connected to a particular interface a Dev...

Page 21: ...ss to port information DevTop Chassis View Access From the Icon Subviews menu for the Atlas Device icon select DevTop Chassis The lower panel of the Chassis Device Topology View depicts device and net...

Page 22: ...the device The main Application view identifies all of these application models shows their current condition status and provides access to application specific subviews Figure 8 shows this view in t...

Page 23: ...these applications represent the non proprietary MIBs supported by your device Listed below beneath the title of the SPECTRUM document that describes them are some of the common applications currently...

Page 24: ...CSISCblDvApp DOCSISQOSApp DOCSISBPI2App DOCSISBPIApp DOCSISIFApp Digital Subscriber Line DSL Applications ADSL Device Specific Applications SPECTRUM imports the following device level proprietary MIBs...

Page 25: ...obConApp Page 55 Adtran IQ Probe Status App AdIQProbStaApp Page 61 Adtran TSU IQ Configuration Application AdTSUIQConApp Page 66 Adtran TSU IQ Status Application AdTSUIQStatApp Page 71 Adtran TSU IQ C...

Page 26: ...e 32 Daily Port Status Table View Page 34 Daily Port Error Table View Page 35 Daily History Time Table View Page 36 History Control Information View Access From the Icon Subviews menu for the AdFRPerf...

Page 27: ...he number of frames the PVC has received for the interval Frames Tx The number of frames the PVC has transmitted for the interval Bytes Rx The number of bytes the PVC has received for the interval Byt...

Page 28: ...f Backward Explicit Congestion Notifications BECNs the PVC has received for the interval BECN Tx The number of BECNs the PVC has transmitted for the interval DE Rx The number of DEs the PVC has receiv...

Page 29: ...y in milliseconds on the PVC for the interval Applies only if Delay Measurement is enabled for the PVC or PVC Diagnostics are being performed Avg Delay The average delay in milliseconds on the PVC for...

Page 30: ...interval Full Status Rx The number of PVC signalling full status frames received Full Status Tx The number of PVC signalling full status frames transmitted Link Integrity Only Rx The number of PVC si...

Page 31: ...ed with a DLCI value less than 16 or greater than 1007 not including PVC signaling frames Unroutable The number of frames received on a management DLCI destined for the IQ unit that have the wrong IP...

Page 32: ...in the inactive state Frames Rx The number of frames the PVC received for the day Frames Tx The number of frames the PVC transmitted for the day Bytes Rx The number of bytes the PVC received for the...

Page 33: ...r the day BECN Rx The number of Backward Explicit Congestion Notifications BECNs the PVC received for the day BECN Tx The number of BECNs the PVC transmitted for the day DE Rx The number of DEs the PV...

Page 34: ...e PVC Min Delay The minimum delay on the PVC for the day Applies only if delay measurement or PVC diagnostics are enabled for the PVC Avg Delay The average delay on the PVC for the day Applies only if...

Page 35: ...The number of PVC signalling full status frames received Full Status Tx The number of PVC signalling full status frames transmitted Link Integrity Only Rx The number of PVC signalling link integrity...

Page 36: ...s in the inactive state Invalid DLCI The number of frames received with a DLCI value less than 16 or greater than 1007 not including PVC signaling frames Unroutable The number of frames received on a...

Page 37: ...uniquely identifies the DS1 interface Alarm Enable Allows you to enable or disable the generation of DS1 Alarm Traps for line status event changes Can be set to dslAlarmOFF or dslAlarmON Line Event Th...

Page 38: ...e DS1 interface Alarm Enable This allows you to enable or disable the generation of DS1 Alert Traps for Performance Monitor Threshold Crossing Alerts Current Alert This DS1 performance status variable...

Page 39: ...n this variable when the value of the Far End Total Table object exceeds the Threshold Value This variable contains the sum of alert values See Table 5 for the bit position values Total Arm This DS1 p...

Page 40: ...te BER level of 10 5 Severely Errored Framing Seconds The DS1 performance monitor threshold value for the current 15 minute severely errored framing seconds parameter The default value is 2 for an app...

Page 41: ...ds The DS1 performance monitor threshold value for the total errored seconds parameter The default value is 648 for an approximate BER level of 10 5 Severely Errored Seconds The DS1 performance monito...

Page 42: ...mate BER level of 10 5 is 648 CRC errors Line Code Violations The DS1 performance monitor threshold value for the total line code violations parameter The default value is 133 400 for an approximate B...

Page 43: ...Possible options are terminal slip and ppp Configuration Save Abort Abort Configuration A set will cancel the current selections and revert to the last Saved config Save Configuration A Set operation...

Page 44: ...ace Port Clock Source The timing source for the DDS interface Management DLCI Configuration DLCI 1 Mode Sets the mode for the management DLCI 1 DLCI 2 Mode Sets the mode for the management DLCI 2 DLCI...

Page 45: ...Access From the Icon Subviews menu for the AdDSUIQConApp icon select DTE Port Configuration This view provides the following information Physical Layer Configuration Port Interface Allows you to selec...

Page 46: ...m the Icon Subviews menu for the DSUIQConfigApp icon select PVC Configuration This view provides PVC Configuration information Double click on an entry to open the PVC Configuration Detail view Config...

Page 47: ...ted from the network The options are enable or disable Loss of Sealing Current Option This enables the unit to enter backup mode when a loss of sealing current is detected from the network Loss of LMI...

Page 48: ...Auto Restore Timer This option selects the amount of time that the DSUIQ circuit must be active before the unit switches from backup to normal mode of operation The timer value is in minutes from 0 t...

Page 49: ...ort when an external DCE device is used Adtran DSU IQ Status Application AdDSUIQStatApp This application has the following available application specific subviews Current Status View DDS Interval Stat...

Page 50: ...connect2d4 sendingPasscode waitingPasscode invalidPasscode validPasscode and error DBU Port Type The DBU card type installed Possible types are empty v34modem dce sw564wire sw562wire and isdn DTE Sig...

Page 51: ...is set for 56K mode or the number of DDS framing errors when the DDS is set for 64K mode DDS Daily Status Table View Access From the Icon Subviews menu for the AdDSUIQStatApp icon select DDS Daily Sta...

Page 52: ...al Max Thruput Tx The maximum throughput the port transmitted for the interval Max Thruput Rx The maximum throughput the port received for the interval Avg Utilization Tx The average utilization the p...

Page 53: ...provides the following information Slot Index The instance for this entry Frames Rx The number of frames the port received for the day Frames Tx The number of frames the port transmitted for the day B...

Page 54: ...greater than 4500 bytes Encapsulation Errors Number of frames destined for the IQ IP stack with that does not meet the FRF 3 IA Unroutable Frames Number of frames received on a management DLCI destin...

Page 55: ...ew Page 55 Trap Manager Table View Page 56 DCE Port Configuration View Page 56 DTE Port Configuration View Page 58 PVC Configuration Table View Page 46 DBU Configuration View Page 59 System Configurat...

Page 56: ...s Network Alarm State Allows you to monitor the alarm state Ar Disarm Network Alarms Allows you to arm disarm network alarm by clicking on appropriate box Trap Manager Table View Double clicking on an...

Page 57: ...aling The signaling type for the frame relay management interface Types include none conLMI ansiT1617D ituTQ933A and auto Link Integrity Poll Timer T391 Sets the polling interval in seconds for the fr...

Page 58: ...Transmit clock Either normal or inverted Flow Control Determines how the IQ device will respond to congestion during DBU operation If set for none the IQ will drop frames during DBU operation when sev...

Page 59: ...nit as originate or answer One end must be set to originate and the other end to answer Carrier Detect Loss This option enables the unit to enter backup mode when loss of Carrier Detect on the DCE int...

Page 60: ...ckup lockout when daily or weekend lockout mode is active Weekend Lockout This option enables or disables Weekend Lockout for Dial Backup operation If enabled no backup will occur from midnight Friday...

Page 61: ...for the ISDN interface ISDN SPID 2 This option is used to set the SPID for the ISDN interface ISDN LDN 1 This option is used to set LDN for the ISDN interface ISDN LDN 2 This option is used to set LD...

Page 62: ...s are Test RD CTS Alarm TD RTS and DCD DTE Control Leads The current state of the DTE control leads Possible selections are CTS DSR DCD RTS and DTR DCE Control Leads The current state of the DCE contr...

Page 63: ...the DBU port was active CRC Errors Number of frames received with CRC errors Abort Frames Number of frames received without proper flag termination Octet Violations Number of frames received with a bi...

Page 64: ...ut Rx The maximum throughput the port received for the day Avg Utilization Tx The average utilization the port transmitted for the day Avg Utilization Rx The average utilization the port received for...

Page 65: ...tance for this entry Unavailable Seconds Amount of time in seconds the DCE port is unavailable due to test or in an inactive state DSR State Change Number of changes in the DCE port Data Set Ready sig...

Page 66: ...the following information T1 Interface Configuration Port Frame Type The Frame type for T1 interface Possible values are d4 eSF and auto Port Clock Source Timing source for the transmit side of the T1...

Page 67: ...passed to the attached frame relay DTE device DLCI 1 PVC 1 Address Sets the address for management PVC 1 Range 16 1007 DLCI 2 PVC 2 Address Sets the address for management PVC 2 Range 16 1007 Frame R...

Page 68: ...ption Either normal or forcedOn Transmit Clock Phase Sets the phase of the DTE Transmit clock Either normal or inverted Flow Control Determines how the IQ device will respond to congestion during DBU...

Page 69: ...etup DBU Mode This option specifies the dial backup operating mode for the unit as originate or answer One must be set to originate and the other end to answer Network Failure Option This option enabl...

Page 70: ...the hour to end dial backup lockout when daily or weekend lockout mode is active Weekend Lockout This option enables or disables Weekend Lockout for Dial Backup operation If enabled no backup will oc...

Page 71: ...terface ISDN SPID 2 This option is used to set the SPID for the ISDN interface ISDN LDN 1 This option is used to LDN for the ISDN interface ISDN LDN 2 This option is used to set LDN for the ISDN inter...

Page 72: ...Port Type Returns the DBU card type installed Possible types are empty v34modem dce sw564wire sw562wire and isdn DTE Signaling State Current state of the PVC signaling between the TSUIQ and the attach...

Page 73: ...e service provider has lost frame alignment PLL Alarm Event Active state represents one or more PLL alarm events PLL alarm is an indication that the transmit and receive side of the T1 interface are n...

Page 74: ...lost frame alignment PLL Alarm Event Active state represents one or more PLL alarm events PLL alarm is an indication that the transmit and receive side of the T1 interface are not looped timed This wi...

Page 75: ...n Tx The average utilization the port transmitted for the interval Avg Utilization Rx The average utilization the port received for the interval Max Utilization Tx The maximum utilization the port tra...

Page 76: ...r the day Bytes Rx The number of bytes the port received for the day Bytes Tx The number of bytes the port transmitted for the day Avg Thruput Tx The average throughput the port transmitted for the da...

Page 77: ...s not meet the FRF 3 IA Unroutable Frames Number of frames received on a management DLCI destined for the IQ unit and have the wrong IP address Adtran TSU IQ Configuration Application AdTSUIQPConApp T...

Page 78: ...it PRM Enables performance report generation across the T1 FDL for the T1 interface Either pRMon or pRMoff Frame Relay Management Interface Config uration Port Signaling Signaling type for the frame r...

Page 79: ...s for storage History Intervals Available Returns the number of history intervals allowed based on the maximum number of PVCs selected Sampling Rate Allows you to set the sampling rate for frame relay...

Page 80: ...U Interval Status Table View Page 83 DBU Daily Status Table View Page 84 DSX Interval Status Table View Page 86 DSX Daily Status Table View Page 87 Diagnostic Table View Page 54 Current Status View Ac...

Page 81: ...an inactive state State Change Number of changes in the T1 port state This includes all normal inactive and test state transitions Signal Loss Event An active state represents one or more signal loss...

Page 82: ...avail Secs Amount of time in seconds the T1 port is unavailable due to test or in an inactive state State Change Number of changes in the T1 port state This includes all normal inactive and test state...

Page 83: ...bviews menu for the AdTSUIQPStaApp select DBU Interval Status Table This view displays the following information Slot Index The instance for this entry Frames Rx The number of frames the port received...

Page 84: ...y the IQ unit Length Errors Number of frames received that is less than 5 bytes or greater than 4500 bytes Encapsulation Errors Number of frames destined for the IQ IP stack with that does not meet th...

Page 85: ...imum utilization the port transmitted for the day Max Utilization Rx The maximum utilization the port received for the day DBU Active Time Time in seconds the DBU port was active CRC Errors Number of...

Page 86: ...ramed all ones condition from the T1 service provider Red Alarm Event Active state represents one or more AIS events AIS is triggered by unframed all ones condition from the T1 service provider Yellow...

Page 87: ...ed all ones condition from the DSX service provider Red Alarm Event Active state represents one or more AIS events AIS is triggered by unframed all ones condition from the T1 service provider Yellow A...

Page 88: ...le contains DSUIV test and remote configuration status information Possible values are normal dteOnly localLoopOnly localDTEandLoop remoteConfigMaster remoteConfigSlave remoteLoop remoteLoopTP dteWith...

Page 89: ...ctive simultaneously Possible statuses are OOS OOFcode NoReceiveSignal NoSealingCurrent NoFrameSync AttemptRateAdapt RTtest LLtest and DBUInProgress This opens another DSU IV Status View that is descr...

Page 90: ...he status bit positions are listed in Table 8 DBU Status This status variable contains the DBU card s status information The status is a bit mapped sum multiple bits can be active simultaneously The s...

Page 91: ...DBU Connection Test This option performs a DBU Connection Test The Set value selects the phone number to dial the remote unit A value of 0 selects the Dial Backup string 1 to 10 selects the stored ph...

Page 92: ...operation commands the DSUIV to turn the audible beeper off Hang Up Call A Set operation commands the DSUIV to terminate the current call Answer Call A Set operation commands the DSUIV to answer the i...

Page 93: ...index that identifies the stored Host Trap Address IP Address The Host Trap IP Address in dotted notation For example 192 239 232 59 Network Configuration View Access From the Icon Subviews menu for t...

Page 94: ...nter backup mode when a loss of sealing current is detected from the network On Pattern Option This option enables the unit to enter backup mode when a pattern of all ones or zeros is received that ex...

Page 95: ...Caller ID Option This option enables or disables dial backup Caller ID When this feature is enabled a DSUIV with an installed ISDN dial backup module can verify the source of an incoming call to provi...

Page 96: ...0 seconds Redial Timer This option works in conjunction with the Redial Counter option The Redial Timer specifies the amount of time between redial attempts The Redial Timer value is seconds up to a m...

Page 97: ...for operation as either RS 232 1 or V 35 DTE Data Scrambler This option enables or disables DTE data scrambler when network loop rate is operating at 64 kbps Command Mode This option selects the comm...

Page 98: ...eration for the data set ready SR lead Possible values are forcedOn offOOSOnly offLOCDOnly offTESTOnly offTEST OOS and offTEST LOCD Transmit Clock Source This option selects the transmit clock source...

Page 99: ...isables DSUIV acceptance of remote digital loopback command DBU Answer Test This DBU test option enables the unit to answer a dial backup call to perform a DBU Connection test When enabled and not in...

Page 100: ...network manager Reboot A set will reboot the TSU 600E Current T1 Map The currently active T1 Map Either MapA or MapB Enable Traps Allows you to enable disable traps Current Time The current TSU600E ti...

Page 101: ...ns are OK ALARM TEST and ERROR Adtran TSU 120e Application AdTSU120eApp This application has the following application specific subviews TSU 120e Configuration View Page 101 LED States View Page 102 T...

Page 102: ...ation The modem initialization string used by the TSU600E Cancel Test Modes A set will cancel all tests modes on the TSU 120E Unit ID The unit identification number for the TSU120E Send Traps Method M...

Page 103: ...Ds A Bitmap of the Controller IDs proxied by this controller Power Supply Select Smart16 power supply configuration Controller LED Status Table Slot Interface This index value uniquely identifies the...

Page 104: ...Indicates the result of the last command executed DTE Port Status The TSU ESP DTE port status DTE Port Data The TSU ESP DTE port data ESP DBU Card The type of ESP Dial Backup Card installed in the TSU...

Page 105: ...menu for the AdTSUESPApp icon select Test Operation This view provides the following information DTE Loopback This allows you to turn the TSU ESP DTE loopback either on or off Current History Status...

Page 106: ...ackup Card A Set operation commands the TSU ESP Dial Backup Card to go off hook and dial the number selected by the value Values 0 through 9 select the corresponding stored number in the phone number...

Page 107: ...send SNMP Trap messages for alarm conditions The SNMP Traps are sent to stations specified in the Trap IP Address table The options are disable send mib 2 standard traps or enable all traps including...

Page 108: ...led originate answer and answerAlways Weekend Lockout This allows you to select whether the weekend lockout feature is lockout enabled or lockout disabled Enable DBU by hour This selects the hour to r...

Page 109: ...DCE DBU Options Pattern Verification This option is used to select the DBU pattern verification option average Physical Interface This option is used to select the physical interface option available...

Page 110: ...mation DSO Rate Selects DS0 rate 56 kbps or 64 kbps DSO Channels Selects alternating or consecutive DS0 channels DTE Transmit Clock Source Select internal external or internal invert TSU ESP clock sou...

Page 111: ...select Test Configuration This view provides the following information Test Timeout secs This sets the length of time in seconds the TSU ESP remains in a test before automatically exiting A zero value...

Page 112: ...nce for this entry Slot The physical slot in the Atlas identified by IfIndex Port The physical port in the Atlas identified by IfIndex Physical Table Index The instance for this entry Physical Slot Th...

Page 113: ...es the port number of a particular port on an option card within the ATLAS product OID This variable indicates the OID that points to the specific MIB that references this particular type of Option Ca...

Page 114: ...er corresponds to the slot number into which the Option Card has been placed Overall Status A bit encoded variable that gives the overall status of the Option Card It is encoded as listed in Table 12...

Page 115: ...anges accordingly Values are listed in Table 15 CSU LED Error Status The CSU Error LED status When the state changes this variable changes accordingly Values are listed in Table 16 Table 13 System LED...

Page 116: ...800 product Card Status The status of the card located in the slot determined by the Index variable Online Status Indicates whether the card located in the slot determined by the Index is online or of...

Page 117: ...ble This variable indicates the interface number of a particular V35Nx56 port within the ATLAS product This number will be the same as the ifIndex located in the MIB II interface table Index The insta...

Page 118: ...ta Rate This variable indicates the current data rate of an interface on a V35Nx4 Option card PLL Fifo Status This bit encoded variable indicates the current state of the PLL Fifo Status for an interf...

Page 119: ...in the adjacent table Generally you determine performance at the device level through Performance views accessed from the Device and Application icons You determine performance at the port interface...

Page 120: ...ge 46 DBU Configuration View Page 47 Unit Configuration View Page 106 Network Configuration View Page 107 DBU Configuration View Page 108 Port Configuration View Page 110 Dial Configuration View Page...

Page 121: ...Service Information Pressing the Help button opens a view that provides a detailed description of this view JK2 of Type AdtranDev of Landscape X Primary Primary Application System Up Time Interface Ty...

Page 122: ...tran product revision number Product Physical Address This octet string contains the Adtran physical address assigned to this product For example the octet sequence 16 02 03 01 specifies channel bank...

Page 123: ...he Common Language Location Identifier Frame Identifier The Channel Bank Frame Identifier Channel Unit Information Number of Channels This value contains the number of channels used by the product For...

Page 124: ...ws for a complete description of this view Figure 11 Model Information View Model Name Contact Description Location SpectroGRAPH Model Name File View Tools Bookmarks Help IP Address of AdtranDev of La...

Page 125: ...IQ Probe Configuration 55 Applications 22 Common 23 Device Specific 24 Atlas 800 Management Group 112 Atlas 800 Physical Table 112 ATLAS V35Nx56 Interface 117 Average Frame Size Received 28 33 Transm...

Page 126: ...Overall Module Status 114 Global Trap Setting 106 H Hardware 8 I Icon Chassis Module 18 Ethernet Chassis Module 18 Icon Subviews Menu Chassis Module 18 Icons Device 10 Interface 15 Inactive DLCI 31 36...

Page 127: ...19 Port Management DLCI 45 Port Name 113 Port Number 113 117 Port Number Device 15 Product Identification Information 122 R Receiver Sensitivity 108 Redial Count 109 Redial Timer 109 Remote Loopback 1...

Page 128: ...I n d e x I n d e x D e v i c e M a n a g e m e n t Page 128 A d t r a n D S U C S U...

Reviews: