13
-
English
Safety precautions / Technical Characteristics
AP009059
AP009060
AP009061
AP009062
AP034001
Fig.1
Fig.2
2.1 WORKING CLOTHES
To work in full compliance with the safety regulations:
•
wear type-approved working clothes and personal
protection equipment (working shoes, protection goggles,
gloves and hard hat);
•
do not wear objects that may get caught somewhere (ties,
bracelets, necklaces, etc.).
Warning
!
Suitably delimit the intervention area to keep non-
authorized people away.
2.2 RESIDUAL RISKS
Warning
!
When the gate is opening, do not put your hands or other
parts of your body close to the area where the operator
gear works. You can be injured.
2.3 ALLOWED USE
This automation has been designed to automate tilt-up doors
with counterweight provided they fall within the application
fi eld of the automation (see par. 2.3.1).
Warning
!
• The use of the product for purposes other than those
stated by the manufacturer is expressly forbidden.
• Do not alter or tamper the product.
• The product must be installed using original material
only.
Caution
The automation cannot be regarded as a supporting or
safety element of the door; the latter must be equipped
with adequate supporting and safety systems.
2.3.1 Application fi eld
Max door panel surface
N˚ 1 oper.
Max width 3.5 m
N˚ 2 oper.
Max width 5 m
Max height 3 m
Max height 3 m
Warning
!
The operator has been designed for application on gates of residential buildings rated for max 50 cycles a day.
3.1 TECHNICAL FEATURES
Counter-weighted up-and-over doors
Technical features
Application
Electromechanical
Technology
230 V 50/60 Hz
Power supply
250 W
Absorbed power
1,6 A
Absorbed current
150
°
C
Overload setting
-20
°
/ +70
°
C
Functioning temperature
450 Nm
Nominal torque
IP 44
Degree of protection
24 V dc
Auxiliary power supply
17 sec
Opening time
50Hz
+60°C
WARNING: If the power supply cable is damaged,
it must be replaced by the manufacturer or its
technical assistance service or in any case by
a similar qualified person, in order to prevent
any risk.
Noise emitted during working process
≤
70dB.
The maximum height of 2000mt of altitude must be
respected for the installation of the motor.
The installer must check that the temperature range
marked on the appliance plate is suitable for the location.