- 8 -
Cod. 67954-0016900 04/00
PROGRAMMING TABLE
SW1
S1
S2
S3
FUNCTION MODE
S4
S5
PREFLASHING
ON
ON
ON
AUTOMATIC
OFF OFF NO PREFLASHING
ON
ON
OFF
SEMIAUTOMATIC
OFF
ON PREFLASHING DURING CLOSING
ON
OFF
ON
SUPER AUTOMATIC
ON
OFF PREFLASHING DURING OPENING
ON
OFF
OFF
DEAD MAN
ON
ON PREFLASHING DURING OPENING/CLOSING
OFF
ON
ON
INSTALLATION
OFF
ON
OFF
OPEN-CLOSE
S7
PHOTOCELL ZEROING
OFF
OFF
ON
STEP BY STEP
ON
PHOT. + LOGIC ZEROING
OFF
OFF
OFF
DIAGNOSTICS
OFF
LOGIC ONLY
S6
TYPE OF FLASHING
S8*
PHOTOCELL FUNCTION
ON
STEADY
ON
STAND-BY BLOCK
OFF
INTERMITTENT ½ SEC.
OFF
NO CONTROL
Partial opening time Pause
JP2
RPM SENSOR SELECTION
ON
RPM SENSOR NO
OFF
RPM SENSOR YES
Braking
Details: zone "A" allows you to set the braking
efficiency or time, which is always set at 3 seconds.
A setting at zone "B", on the other hand, completely
overrides the braking stage which is set at a duration
of "0" seconds.
CAUTION
EACH TIME THE OPERATOR IS PROGRAMMED, TURN OFF THE POWER
SUPPLY TO CANCEL THE PROGRAM PREVIOUSLY SET.
RV2
RV4
RV3
RV1
Speed during braking
* When enabled with dipswitch S8, the Stand-by
photocell control function prevents the start pulse from
being accepted if the photocells are obscured with the
gate closed. When the photocells are cleared and a start
pulse is sent, the gate opens.
Speed during braking