background image

 

 

 

DESCRIPTION 

The  CV10  unit  is  an  electronic  board  for  the  automation  of  doors,  windows  and gates with the help of electro-mechanic 
actuators. 
 

BLOCK DIAGRAM OF EQUIPMENT 

 

F1 = 2A fuse for 230 V power supply 
F2 = 10A fuse for 24 V power supply 
J1 = Control and drive terminal board 
J2 = 230 V power supply terminal board 
TF1 = Transformer 
RL1-RL2 = Open/close switch relay 
RL3 = Drive priority management relay 
DB1 = 10 A rectifier bridge 

 

 

 

CV10 TERMINAL BOARD DESCRIPTION 

 

1  Terminals  1  and  2:  power  supply  for  the 

actuators.  Connection  for  supplying  power  to 
24Vdc  actuators  with  maximum  absorption  of 
8A. 

2  Terminals  3,  4  and  5:  open/close  command 

(local).  Contact  for  commanding  opening  and 
closing  of  the  actuator.  The  operation  of  this 
contact has priority over terminals 6, 7 and 8. 

3  Terminals  6,  7  and  8:  open/close  command 

(local).  Contact  for  commanding  opening  and 
closing of the actuator without any priority. When 
the centralised contact is enabled, every function 
is  disabled  and  is  re-enabled  only  when  the 
centralised contact is in the rest position. 

4  Terminals N and L: 230 V, 50 Hz power supply. 

L = PHASE 
N = NEUTRAL 

 
 

N.B.   Connect PV1 to either "3 and 4" or to "4 and 

5"  as  required,  making  sure  that  the 
emergency  rain-wind  gives  the  closing 
command. 

 

 

Summary of Contents for 8032434034827

Page 1: ...cod 7954 00 16200 CV10 I ISTRUZIONI TECNICHE GB TECHNICAL INSTRUCTIONS F NOTICES DE POSE D TECHNISCHE ANLEITUNG E INSTRUCCIONES T CNICAS...

Page 2: ...alimentare attuatori a 24 volt D C con massimo assorbimento di 8A 2 Morsetti 3 4 e 5 comando apre chiude centra lizzato Contatto per comandare l apertura e la chiusura dell attuatore L intervento di q...

Page 3: ...na CV10 e potr essere del nostro tipo PUL 3 o di tipo commerciale Sono collegabili in parallelo tra di loro pi centraline CV10 con un unico pulsante centralizzato tipo PUL 3 oppure potranno essere col...

Page 4: ...ion for supplying power to 24Vdc actuators with maximum absorption of 8A 2 Terminals 3 4 and 5 open close command local Contact for commanding opening and closing of the actuator The operation of this...

Page 5: ...must be connected directly to the CV 10 control device Several CV 10 control devices can be connected in parallel using a single PUL 3 type centralised switch Alternatively several CV 10 control devic...

Page 6: ...s Permet d alimenter les actionneurs 24 Vcc avec une absorption maximale de 8A 2 Bornes 3 4 et 5 commande ouvrir fermer centra lis e Contact qui commande l ouverture et la fermeture de l actionneur L...

Page 7: ...i directement la centrale CV10 Plusieurs centrales CV10 peuvent tre connect es en parall le avec un seul bouton centralis du type PUL 3 On peut galement connecter entre elles plusieurs centrales CV10...

Page 8: ...u f r die 24 Volt DC mit maximaler Stromaufnahme von 8A 2 Klemmen 3 4 und 5 Steuerbefehl ffnen Schlie en zentral Kontakt zur Steuerung der ffnungs und Schlie bewegung des Antriebs Dieser Kontakt hat V...

Page 9: ...er Typ PUL 3 oder handels blich kann direkt mt der Zentrale verdrahtet werden Mehrere Zentralen CV 10 sind parallel schaltbar mit einem einzigen Schalter PUL 3 oder mehrer Zentralen CV 10 k nnen paral...

Page 10: ...actuadores Conexi n para alimentar actuadores a 4V cc con una absorci n m xima de 8A 2 Bornes 3 4 y 5 mando apertura cierre centralizado Contacto para el mando de apertura y cierre del actuador La ac...

Page 11: ...V10 y puede ser del tipo PUL 3 o de otro tipo comercial Varias centrales CV10 pueden conectarse en paralelo presentando un nico pulsador centralizado del tipo PUL3 o bien se pueden conectar igualmente...