With faulty sensor, the component inside the control unit is damaged and replacement of the control
unit is recommended. With signal not valid, the sensor has generated a signal out of range that is still
sent to the injection control unit together with the relevant error.
NOTE: The instrument panel does not indicate the presence of this error even in the ATT status.
NOTE
THIS ERROR DISABLES THE TRACTION CONTROL.
P1905 Wheel stand timeout error
Functional diagnosis:
Timeout error
Error cause:
•
If this error is displayed, it means that the wheel stand control software detected an abnormal
behaviour of the motorcycle.
Troubleshooting:
With faulty sensor, the component inside the control unit is damaged and replacement of the control
unit is recommended. With signal not valid, the sensor has generated a signal out of range that is still
sent to the injection control unit together with the relevant error.
NOTE: The instrument panel does not indicate the presence of this error even in the ATT status.
NOTE
THIS ERROR DISABLES THE TRACTION CONTROL.
Connectors
Electrical system
Tuono V4 1100 Factory
ELE SYS - 250
Summary of Contents for 2Q000504
Page 1: ...SERVICE STATION MANUAL 2Q000504 Tuono V4 1100 Factory ...
Page 4: ......
Page 6: ...INDEX OF TOPICS PRE DELIVERY PRE DE ...
Page 12: ...INDEX OF TOPICS CHARACTERISTICS CHAR ...
Page 55: ...INDEX OF TOPICS SPECIAL TOOLS S TOOLS ...
Page 63: ...INDEX OF TOPICS MAINTENANCE MAIN ...
Page 103: ...INDEX OF TOPICS ELECTRICAL SYSTEM ELE SYS ...
Page 270: ...INDEX OF TOPICS ENGINE FROM VEHICLE ENG VE ...
Page 299: ...INDEX OF TOPICS ENGINE ENG ...
Page 415: ...INDEX OF TOPICS POWER SUPPLY P SUPP ...
Page 425: ...INDEX OF TOPICS SUSPENSIONS SUSP ...
Page 463: ...INDEX OF TOPICS CHASSIS CHAS ...
Page 508: ...INDEX OF TOPICS BRAKING SYSTEM BRAK SYS ...
Page 548: ...INDEX OF TOPICS COOLING SYSTEM COOL SYS ...
Page 561: ...INDEX OF TOPICS BODYWORK BODYW ...