Figure 3

7. Drill the marked holes using a 3/16” drill bit. Note: Enclosed plastic

anchors do not require a drilled hole for drywall.

8. Tap plastic anchors into the wall.

9. Align base with plastic anchors and feed wires through opening.

See Fig 4.

Figure 4

10. Secure base to wall with supplied screws.

11. Connect wires to terminal strip. Refer to wiring diagrams on other

side of this sheet. Make sure wire connections are secure.

12. Place fan option switch into either the “ELEC” or “GAS” position

depending upon the type of furnace. Refer to Figure 5.

Figure 5

4

PROG

MAN

CHANGE

                    SET         AUTO/MAN

Elec
Gas

RH

AM
PM

MORN  DAY EVE  NITE

RC

W

Y

G

FAN  AUTO  ON

MOUNTING HOLES

COOL   OFF   HEAT 

PROG

MAN

CHANGE

                    SET         AUTO/MAN

Elec
Gas

RH

AM
PM

MORN  DAY EVE  NITE

RC

W

Y

G

FAN  AUTO  ON

COOL   OFF   HEAT 

PROG

MAN

CHANGE

                    SET         AUTO/MAN

Elec
Gas

RH

AM
PM

MORN  DAY EVE  NITE

RC

W

Y

G

FAN  AUTO  ON

FAN
OPTION
SWITCH

Controls
fan delay.

COOL   OFF   HEAT 

Summary of Contents for 8353

Page 1: ...ling or programming this thermostat This is a 24V AC low voltage thermostat Do not install on voltages higher than 30V AC All wiring must conform to local and national building and electrical codes and ordinances Do not short jumper across terminals on the gas valve or at the system control to test installation This will damage the thermostat and void the warranty 5 2 Day Programmable 1 Heat 1 Coo...

Page 2: ... cooling system 2 Remove cover of old thermostat to expose wires Do not disconnect wires Fig 1 3 Label wires per Table 1 Table 1 Old Label New Label Description M 4 RH R5 or R RH Heat Transformer hot side V or RC RC Cooling Transformer hot side Y or Y6 Y Cooling control H W or 4 W Heating control F or G G Fan control relay C Y or None Either cooling control or common side of trans former NOTE On s...

Page 3: ... will affect thermostat operation 1 Turn power off to the heating and cooling systems 2 Place COOL OFF HEAT In OFF position 3 Place FAN AUTO ON switch Into AUTO position 4 Remove the cover using a coin or screwdriver Figure 2 5 Place thermostat against the wall at desired location Make sure wires will feed through opening on base of thermostat 6 Mark placement of mounting holes See Fig 3 Set base ...

Page 4: ...rams on other side of this sheet Make sure wire connections are secure 12 Place fan option switch into either the ELEC or GAS position depending upon the type of furnace Refer to Figure 5 Figure 5 4 PROG MAN CHANGE SET AUTO MAN Elec Gas RH AM PM MORN DAY EVE NITE RC W Y G FAN AUTO ON MOUNTING HOLES COOL OFF HEAT PROG MAN CHANGE SET AUTO MAN Elec Gas RH AM PM MORN DAY EVE NITE RC W Y G FAN AUTO ON ...

Page 5: ...ce cover onto thermostat by snapping into place 15 Turn on power to system Test thermostat as described in the following section Programming Guide Set Time of Day Day of Week Temperature Differential 1 Press Hold SET Press PROG MAN Release simultaneously 2 Press or to change Time of Day 3 Press 4 Press To Change Day of Week 5 PROG MAN SET PROG MAN COOL OFF HEAT FAN AUTO ON SET PROG MAN SET P 1 MO ...

Page 6: ...m will turn on If the system turns on too often increase the temperature differential 7 Press SET to finish Changing Fahrenheit F to Celsius C Press and Hold SET Press Release both simultaneously Setting Daily Programming 1 Place COOL OFF HEAT switch in COOL position 2 Press SET 3 Press or to change MORN time in 30 minute intervals 6 SET P SET P PROG MAN SET PROG MAN COOL OFF HEAT FAN AUTO ON COOL...

Page 7: ...TE for weekday operation and two settings MORN and NITE for weekend operation Adjust the program at any time by following the steps as outlined above Begin Programmed Operation 1 Place FAN AUTO ON switch Into AUTO 2 Place COOL OFF HEAT switch Into COOL or HEAT Depending upon the season 3 Press PROG MAN button until indicator is in PROG position 7 PROG MAN SET PROG MAN COOL OFF HEAT FAN AUTO ON SET...

Page 8: ...am settings 1 Press PROG MAN until indicator is in MAN position 2 Press or to adjust temperature settings Reset To reset the thermostat to factory pre programmed conditions press the reset button located directly to the right of the display 8 PROG MAN SET PROG MAN COOL OFF HEAT FAN AUTO ON PROG MAN SET PROG MAN COOL OFF HEAT FAN AUTO ON T PROG MAN PROG MAN PROG MAN CHANGE SET AUTO MAN Elec Gas RH ...

Page 9: ...ioning will result in a 5 minute delay in compressor activation 3 Put the COOL OFF HEAT switch into the OFF position The air conditioning system should turn off The fan may continue to run for a short period of time 4 Put the COOL OFF HEAT switch into the HEAT position 5 Press the button until the temperature setting is at least 3 degrees above room temperature The heating system should turn on Th...

Page 10: ...em fan does not operate Move fan option switch to either properly gas or electric to match system see INSTALLATION Time shown on display is not the Change time of day setting current time of day see PROGRAMMING Thermostat does not Thermostat in MANUAL mode follow program see PROGRAMMING Thermostat may not have been programmed in HEAT or COOL position Verify program Check AM PM indicators at time o...

Page 11: ...RC W Y G RH RC W Y G Hot Heating Control Heating Control Transformer 24 VAC 24 VAC 24 VAC 120 VAC Hot 120 VAC Hot 120 VAC HEAT COOL 4 WIRE SINGLE TRANSFORMER HEAT ONLY 2 WIRE SINGLE TRANSFORMER HEAT ONLY 3 WIRE SINGLE TRANSFORMER Factory Installed jumper Factory Installed jumper T H E R M O S T A T RH RC W Y G Hot Cooling Control Fan Control Transformer 24 VAC 120 VAC COOL ONLY 3 WIRE SINGLE TRANS...

Page 12: ...HANTABILITY OR FITNESS FOR A PAR TICULAR PURPOSE SHALL BE LIMITED IN DURATION TO THE AFORESAID TWO YEAR PERIOD RESEARCH PRODUCTS CORPORATION S LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OTHER THAN DAMAGES FOR PERSONAL INJURIES RESULTING FROM ANY BREACH OF THE AFORE SAID IMPLIED WARRANTIES OR THE ABOVE LIMITED WARRANTY IS EXPRESSLY EXCLUDED THIS LIMITED WARRANTY IS VOID IF DEFECT S RESULT FR...

Reviews: