background image

13

12

MIN/

HR

CODE      

VENT

24 VAC, 10VA TRANSFORMER

PROVIDED WITH MODEL 8126X

24 VAC

120 VAC

MODEL 6506 DAMPER

PROVIDED WITH MODEL 8126X

FIGURE 4 

– WIRING TO MODEL 6506 DAMPER

4. 

Route the wires into the 
channels in the back of the 
control to either the top or 
bottom of the control and 
snap the control onto the 
wall plate .

5. 

Restore power to the HVAC 
system when complete .

WIRE

CHANNEL

90-2266

OPERATION

The display will appear faint normally; the first press of any button will turn on the display at full 
power .

Use for  
Rater/Inspector 
Verification . 
Press and hold 
for 5 seconds to 
enter Test Mode 
or Set Up Menu .

Lights green 
when ventilating .

Shows the ventilation time setting (minutes/hr), 

mode of operation (Code or Comfort) and whether 

the HVAC fan has been turned on when ventilating .

Use to override the 
calculated ventilation 
time setting (6 – 60 
minutes/hr) . Press 
and hold   to turn 
ventilation OFF .

To return to the 
calculated setting, go 
completely through 
the Set Up Menu .

Summary of Contents for 8126

Page 1: ...MIN HR CODE READ AND SAVE THESE INSTRUCTIONS Model 8120X Digital Ventilation Controller Installation and Operation Manual ...

Page 2: ...Sequence of Operation Comfort Setting 19 Limited Warranty 20 WARNINGS AND CAUTIONS WARNING 120 volts can cause serious injury from electric shock Disconnect electrical power to the HVAC system before proceeding Sharp metal edges can cause serious injury from cuts Use gloves when cutting openings in sheet metal NOTICE When installing the Ventilation Controller on downflow furnaces ensure that the f...

Page 3: ...ntilation with high indoor RH is important mount the control to the return duct and mount the outdoor temperature sensor as shown on pages 6 9 If humidity limits will not be used then the control can be mounted to the housing of the Model 8140NC and the outdoor temperature sensor does not need to be installed 1 Remove the wall plate from the control and put the rest of the control in a safe locati...

Page 4: ...CT WALL PLATE 8 HEX HEAD SCREWS 5 8 DIA HOLE PILOT HOLES FOR SCREWS 6 MIN 90 2269 Duct Board Installation 1 Take out the duct board mounting bracket remove the wall plate from the control and put the rest of the control in a safe location until after wiring is completed 2 Cut a 5 75 x 5 25 rectangular opening in the return plenum Save the piece cut out to insulate the duct board bracket around the...

Page 5: ... rest of the control in a safe location until after wiring is complete 2 Use spacers or brackets to mount the controller to an inside wall surface or return plenum duct surface that is at room temperature i e do not mount to supply ductwork or to the air handler furnace to space the wall bracket a minimum of away from the surface 3 Mount the wall bracket to the surface using 8 screws field supplie...

Page 6: ...e damper in Model 8126X installations or to the Model 8140NC Fresh Air Ventilator and wire according to FIGURE 3 or FIGURE 4 MODEL 8120X DIGITAL VENTILATION CONTROL R C Y W G R C Y W G THERMOSTAT WIRE NUT FIELD SUPPLIED R C Y W O GS GH FURNACE R C 24 VAC Y COOLING W HEAT GS FAN INPUT GH FAN OUTPUT VENT ODT OUTDOOR TEMPERATURE SENSOR FIGURE 1 WIRING TO FURNACE MODEL 8120X DIGITAL VENTILATION CONTRO...

Page 7: ...0 2266 OPERATION The display will appear faint normally the first press of any button will turn on the display at full power Use for Rater Inspector Verification Press and hold for 5 seconds to enter Test Mode or Set Up Menu Lights green when ventilating Shows the ventilation time setting minutes hr mode of operation Code or Comfort and whether the HVAC fan has been turned on when ventilating Use ...

Page 8: ...irflow delivered during ventilation HP F CODE NO OF BEDROOMS HIGH OFF 85 F 105 F Ventilation high temperature limit Ventilation is limited when the outdoor temperature exceeds the setting Turn OFF if no high limit is desired HP F COMFORT HOUSE FT2 LOW OFF 10 F 40 F Ventilation low temperature limit Ventilation is limited when the outdoor temperature falls below the setting Turn OFF if no low limit...

Page 9: ...ops below the setting ventilation will not occur When all Set Up Menu options have been entered the control will display donE TEST MODE After wiring and set up have been completed Test Mode can be used to verify that all components in the ventilation system function and that wiring to the HVAC system fan is correct 2 3 Test Sequence Description HP F HC Shows outdoor temperature as measured by the ...

Page 10: ... starts again it will sample the air temperature and if in range will meet the set amount of ventilation during the four hour cycle period For example if the Vent Time was set to 25 minutes per hour and the air temperature fell below the low limit setting ventilation would only occur during a heating call If the heating only operated for 10 minutes during the hour the control will automatically ch...

Page 11: ...ESULTING FROM ANY BREACH OF THE AFORESAID IMPLIED WARRANTIES OR THE ABOVE LIMITED WARRANTY IS EXPRESSLY EXCLUDED THIS LIMITED WARRANTY IS VOID IF DEFECT S RESULT FROM FAILURE TO HAVE THIS UNIT INSTALLED BY A QUALIFIED HEATING AND AIR CONDITIONING CONTRACTOR IF THE LIMITED WARRANTY IS VOID DUE TO FAILURE TO USE A QUALIFIED CONTRACTOR ALL DISCLAIMERS OF IMPLIED WARRANTIES SHALL BE EFFECTIVE UPON INS...