 Model 8051 FluSh Mount SenSor InStallatIon InStructIonS

Step 1:

   Use a 1” paddle bit to drill a 1” dia. hole in the drywall/sheetrock. Keep the drill steady and horizontal to ensure a clean finished hole.

Step 2:

   Wire nut the sensor to cable run between the flush mount sensor and the thermostat or support module. Press the sensor into the 1” hole 

after the wires are connected.

 

IMportant:

 Do not spackle or mud over the sensor. The sensor must protrude 1/64” from the wall for accurate temperature reporting.

Step 3:

   Wire the sensor to the thermostat or support module. Refer to the instructions provided with these devices for additional details.

1”

1.00”

THERMOSTAT 

OR 

SUPPORT MODULE

note:

 Paint or apply wall paper to the sensor 

disk prior to installing the sensor into the wall.

PRESS FLUSH MOUNT TEMPERATURE SENSOR 
INTO 1” HOLE. NO FASTENERS REQUIRED.