background image

MODEL 400

- 10 -

1. Front Cover

2. Feed Tube

3. Integral Bypass Damper

4. Water Panel Evaporator

Assembly

5. Distribution Tray

6. “V” Notches

7. Water Panel

8. Scale Control Insert/Float

Chamber

9. Overflow Hose

10. Float Cover

11. Float

12. Water Level Sensor Assembly

1. Note Humidifier Control setting and turn dial to the “Off” position.

2. Turn off water supply. Turn the integral bypass damper (3) to the SUMMER position.

3. Press the tabs in the latches on the top and bottom of front cover (1) and pull cover off base with both

hands.

4. Carefully pull the plastic feed tube (2) out of the distribution tray (5) at the top of the Water Panel

evaporator assembly (4). Tip the Water Panel evaporator assembly forward and lift it out of the
humidifier. 

Do not

tip the Water Panel evaporator assembly more than needed to clear the housing to

avoid over-bending the water level sensor assembly (12).

5. Unsnap the distribution tray (5) from the scale control insert (8). Follow the instructions below

depending upon the type of distribution tray in your humidifier:
For trays with a synthetic fabric liner: Lightly scrape out or brush off any mineral deposits, being
careful not to stretch or loosen the synthetic fabric liner. Soaking the tray in vinegar or a lime-
removing agent is helpful when trying to remove stubborn mineral deposits. 
For trays with granular coating:

Do not scrape off the granular coating, 

but lightly scrape out any

mineral deposits and clean the “V” notches (6)

.

This textured surface helps ensure even water flow

for maximum performance. See page 3 if removed. 

6. Slide the used water panel (7) out of the scale control insert/float chamber and dispose of the water

panel. 

7. Remove the float cover (10) and inspect the floats (11) and float chamber for mineral build-up. Remove

deposits as needed from floats, float chamber and scale control insert. Wash the parts with a
disinfecting cleaner. Reassemble the floats and float cover. Make sure stems of both floats extend
through openings in float cover and that floats move freely up and down.

8. Inspect the plastic feed tube (2) by gently flexing it and looking for cracks or signs of wear. Replace

tube if it is cracked, brittle, or has been damaged.

9. Slide a new Aprilaire No. 45 water panel (7) into the scale control insert/float chamber (8). Snap the

distribution tray (5) back on the scale control insert (8).

10. Re-install the Water Panel evaporator assembly (4) into the humidifier. Take care not to over-bend the

water level sensor assembly. Push the top of the Water Panel evaporator assembly firmly back until it
snaps into place.

11. Push the end of the feed tube back firmly into the distribution tray. Replace the front cover.

12. Remove the overflow hose (9) from the bottom of the unit and flex it to loosen any mineral deposits or

blockage. Then flush with water under pressure and slip it back onto the drain fitting. Make sure the
drain hose has a constant downward slope and is not flattened or blocked.

13. Turn on the water supply. Return integral bypass damper to appropriate position.

14. Check system operation:

Humidifier Control: (Automatic or Manual) Check system operation and reset change water panel
indicator by setting the knob to “Test/Reset”. With furnace blower operating and furnace calling for
heat, humidifier will operate for one minute. DO NOT LEAVE IN TEST MODE AS HUMIDIFIER WILL
NOT OPERATE.

15. Reset Humidifier Control to its original position.

MAINTENANCE INSTRUCTIONS FOR
APRILAIRE HUMIDIFIER MODEL 400

CAUTION! Sudden operation may cause personal injury or 
property damage. Turn Humidifier Control to “off” or 
lowest setting before servicing.

MODEL
400

Summary of Contents for 600

Page 1: ...READ AND SAVE THESE INSTRUCTIONS Owner s Manual For Models 400 550 600 700 Includes Safety Operating Instructions and Warranty Information Automatic Humidifiers ...

Page 2: ...n service parts and or replacement Water Panel evaporators This booklet will familiarize you with the benefits you will receive from the equipment you just purchased and help you understand the routine maintenance required Be sure to register your Humidifier warranty online at www aprilaire com warranty TABLE OF CONTENTS WARNING 120 volts may cause injury from electrical shock Disconnect power and...

Page 3: ...ating water flows to the distribution tray located at the top of the unit The water is uniformly distributed across the width of the tray and through a scientifically designed system of outlets It flows by gravity over the Water Panel evaporator the heart of the unit Dry hot air is moved through the moisture laden Water Panel evaporator where natural evaporation takes place The now humidified air ...

Page 4: ...ribution trays have a granular coating in the bottom of the distribution tray to provide even water flow to each of the openings and over the Water Panel evaporator Do not clean the mineral scale off the bottom of the water distribution tray at the end of the humidification season If the granular coating is removed it is not necessary to purchase a new distribution tray simply apply a small amount...

Page 5: ...uide Condition Solution Condensation on windows Reduce the setting on the control dial by 1 increment Lack of humidity Increase the setting on the control dial by 1 increment Humidifier does not operate Turn dial to Test Reset Make certain furnace is operating in heat mode If unit still doesn t operate contact your heating contractor Humidifier won t shut off Turn dial to Off If unit continues to ...

Page 6: ...r the solenoid valve click off At this point make note of the dial setting 4 Locate your dial setting on Table 2 Follow the dial setting to the right until it intersects with the current outdoor temperature This is the relative humidity in your home under existing conditions 5 Return the thermostat and the Humidifier Control to their original settings The values of outdoor temperature and dial set...

Page 7: ...itable for protection of your home and to avoid condensation on your windows For example a wintertime indoor RH of 50 may be considered ideal but unfortunately it probably would result in damage to your home Observance of the recommended RH levels on your Humidifier Control therefore is an important safeguard Condensation of water on inside windows in the form of fogging or frost is usually an ind...

Page 8: ...the water saddle valve is open and that there is electricity to the unit The furnace blower motor must be operating and the furnace calling for heat for the Aprilaire Humidifier to function Note Turning the knob to Test Reset resets the Change Water Panel internal timer After the humidifier has operated for one minute and water is entering the unit and coming out at the drain reduce the humidistat...

Page 9: ...eral hours your home should be ventilated to dissipate the potential damaging excess moisture levels Your humidifier will operate effectively using either hot cold hard or mechanically softened water Whether to use available tap water even though it may be quite hard or chemically softened water is a common question of homeowners when installing a humidifier Water used in homes contains varying am...

Page 10: ...ine Aprilaire Water Panels to maintain performance If your humidifier is equipped with an automatic control after replacing the Water Panel turn the control knob to the Test Reset position until the Change Water Panel light blinks to reset the Water Panel change indicator timer Blower must be operating and furnace calling for heat Be sure to turn the control knob back to it s original setting 1 Fo...

Page 11: ...tube Double Wrench To Prevent Leaking 10 Remove the drain hose from the bottom of the unit and flex it to loosen any mineral deposits or blockage Then flush it with water under pressure and slip it back onto the drain fitting Make sure the drain hose has a constant downward slope and is not flattened or blocked 11 Turn on water supply and reconnect electrical power to the furnace OUTLET COMPRESSIO...

Page 12: ...the floats 11 and float chamber for mineral build up Remove deposits as needed from floats float chamber and scale control insert Wash the parts with a disinfecting cleaner Reassemble the floats and float cover Make sure stems of both floats extend through openings in float cover and that floats move freely up and down 8 Inspect the plastic feed tube 2 by gently flexing it and looking for cracks o...

Page 13: ... and snap the distribution tray back into place 7 Inspect the plastic feed tube 2 by gently flexing it and looking for cracks or signs of wear Replace tube if it is cracked brittle or has been damaged 8 Re install the Water Panel evaporator assembly 4 into the unit by fitting its drain into the round receptacle at the base of the unit Push the assembly in at the top against the beveled tabs that w...

Page 14: ...35 and with a new Genuine Aprilaire Water Panel Slide the Water Panel evaporator back into the scale control insert with the colored spot up and snap the distribution tray 4 back into place 7 Inspect the plastic feed tube by gently flexing it and looking for cracks or signs of wear Replace tube if it is cracked brittle or has been damaged 8 Re install the Water Panel evaporator assembly 3 into the...

Page 15: ...d with a new Genuine Aprilaire Water Panel Slide the pad back into the insert frame with color mark up and snap the distributon tray back into place 7 Inspect the plastic feed tube 2 by gently flexing it and looking for cracks or signs of wear Replace tube if it is cracked brittle or has been damaged 8 Re install the Water Panel evaporator assembly 4 into the unit by fitting its drain into the rou...

Page 16: ...ARRANTY IS VOID IF DEFECT S RESULT FROM FAILURE TO HAVE THIS UNIT INSTALLED BY A QUALIFIED HEATING AND AIR CONDITIONING CONTRACTOR IF THE LIMITED WARRANTY IS VOID DUE TO FAILURE TO USE A QUALIFIED CONTRACTOR ALL DISCLAIMERS OF IMPLIED WARRANTIES SHALL BE EFFECTIVE UPON INSTALLATION Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incident...

Reviews: