I. PRINCIPLE OF OPERATION

With  your  purchase  of  a  humidification  system,  you  have

invested  in  a  humidifier  that  operates  on  the  evaporative 
principle  –  nature’s  own  way  of  adding  moisture  –  and  will 
provide  the  proper  relative  humidity  all  during  the  heating 
season. It is very possible that you have questions concerning your
new humidifier – questions on what it can do for you, and what you
should  do  to  receive  maximum  benefits  from  it.  This  booklet  is
intended to help you do exactly that.

Nature, in producing an invigorating comfortable April day, com-

bines  just  the  right  temperature  and  the  right  amount  of  moisture.
Aprilaire Humidifiers employ the same principle, with refinements, to
give you the proper relative humidity for maximum allowable com-
fort all winter long.

The important considerations in the evaluation of a humidifier are

Positive Control, Sufficient Capacity, Trouble-free Performance and
Minimum  Maintenance.  The  operating  principle  of  your  Aprilaire
provides all of these advantages. Here, briefly, is the method:

The Aprilaire Humidifier is installed to operate in conjunction with

the  furnace  blower  motor.  When  the  Aprilaire  Humidifier  Control
calls for humidity and the blower motor is operating, water flows to
the distribution tray located at the top of the unit. The water is uni-
formly distributed across the width of the tray and through a scien-
tifically  designed  system  of  outlets.  It  flows  by  gravity  over  the
Water Panel

®

evaporator, the heart of the unit. Dry, hot air is moved

through  the  moisture-laden  Water  Panel  evaporator  where  the
evaporation takes place. The now humidified air carrying moisture in
vapor form (nature’s own way) is circulated throughout the home.

The correct water flow is determined by an orifice equipped

with each drain type unit. When the unit is operating, there will
be a small, steady stream of water to drain, which flushes away
most of the trouble-causing minerals. 

Do not use the saddle valve

to regulate the water flow. It is designed to be completely opened or
closed. The minerals and solid residue not trapped by the replace-
able Water Panel evaporator are flushed down the drain. The drain
also eliminates the problems caused by stagnant water. This is the
most  effective  and  least  expensive  method  to  dispose  of  trouble-
causing minerals.

®

- 2 -

Summary of Contents for 400 Series

Page 1: ... Operating Instructions Automatic Mode 4 Manual Mode 6 Effect of Water Characteristics 8 Annual Maintenance 9 Annual Summer Shutdown 9 Periodic Preventative Maintenance 9 MAINTENANCE INSTRUCTIONS Models 400 11 Model 600 12 Model 700 13 Limited Warranty 14 Replacement Record 18 19 AUTOMATIC HUMIDIFIER The Best Cure For Dryness FOR MODELS 400 600 700 OWNER S MANUAL ...

Page 2: ... to add your name to our growing list of customers With this purchase you have invested in the highest quality equipment currently available Research Products Corporation is the largest manufacturer of whole house humidifiers air cleaners and fresh air exchangers and is a recognized leader in the heating and air conditioning industry today Please be assured that in addition to product quality we a...

Page 3: ...ifier is installed to operate in conjunction with the furnace blower motor When the Aprilaire Humidifier Control calls for humidity and the blower motor is operating water flows to the distribution tray located at the top of the unit The water is uni formly distributed across the width of the tray and through a scien tifically designed system of outlets It flows by gravity over the Water Panel eva...

Page 4: ...s the heart of the unit and must be in good condition to assure high capacity trouble free performance It should be changed once a year with the exception of the Model 400 where it should be changed twice a season The granular coating in the bottom of the distribution tray is designed to provide equal distribution of the water to each of the openings assuring an even flow of water over the Water P...

Page 5: ...ng on your personal comfort and home s requirements Refer to the Operation Guide Table 1 2 During the coldest portion of the first heating season minor 4 Table 1 Operation Guide Condition Solution Condensation on windows Reduce the setting on the control dial by 1 increment Lack of humidity Increase the setting on the control dial by 1 increment Humidifier does not operate Turn dial to Test Make c...

Page 6: ... on Next slowly turn the dial counter clockwise until you hear the solenoid valve click off At this point make note of the dial setting 4 Locate your dial setting on Table 2 Follow the dial setting to the right until it intersects with the current outdoor temperature This is the relative humidity in your home under existing conditions 5 Return the thermostat and the control to their original setti...

Page 7: ... average home These settings represent a compromise between RH levels that would be most desirable for comfort reasons and humidity levels that are suitable for protection of your home and to avoid condensation on your windows For example a wintertime indoor RH of 50 may be considered ideal but unfortu nately it probably would result in damage to your home Observance of the recommended RH levels o...

Page 8: ...coming out at the drain reduce the humidistat setting to the recommended inside relative humidity depending on the outside temperature DO NOT LEAVE IN TEST MODE AS HUMIDIFIER WILL NOT OPERATE Follow the suggested settings prior to a drop in the outside temperature MANUAL MODE Figure B tion of too high relative humidi ties This same condensation can take place in other areas in your home with the p...

Page 9: ...r humidifier will operate effectively using either hot cold hard or mechanically softened water Whether to use available tap water even though it may be quite hard or chemically softened water is a common concern to homeowners when installing a humidifier Water used in homes contains varying amounts of minerals The residue remaining as a result of hard water evaporation is primarily calcium and ma...

Page 10: ...Genuine Aprilaire Water Panels to maintain performance V ANNUAL SUMMER SHUTDOWN 1 For Models 400 and 600 close the bypassdamper With the use of the small damper handle 2 Shut off the water supply to the humidifier by closing the sad dle valve Humidifier Control There is no adjustment to the Humidifier Control required for summer shutdown Applies to both Automatic and Manual Mode VI PERIODIC PREVEN...

Page 11: ...ervice Department Part No 4004 5 Replace the in line strainer and reconnect the inlet water line Double Wrench To Prevent Leaking 6 Disconnect the water line at the outlet compression nut 7 Remove the orifice from the copper or plastic tube and make sure this small opening is unplugged 8 Replace the orifice and reconnect the outlet water line Double Wrench To Prevent Leaking 9 Turn on water supply...

Page 12: ...sert float chamber and dispose of the water panel Inspect the overflow hose 9 to make sure it is open 7 Remove the float cover 10 and inspect the floats 11 and float chamber for mineral build up Remove deposits as needed from floats float chamber and scale control insert Wash the parts with a disinfecting cleaner Reassemble the floats and float cover Make sure stems of both floats extend through o...

Page 13: ...col ored spot up and snap the black distribution tray back into place 7 Re install the Water Panel evaporator assembly into the unit by fitting its drain tube into the round receptacle at the base of the unit Push the assembly in at the top against the beveled tabs that will hold it in place Push the end of the feed tube back firmly into the distribution tray and replace the front cover 8 Remove t...

Page 14: ...to the scale control insert with the red colored spot up and snap the black distribution tray 4 back into place 7 Re install the water panel evaporator assembly 3 into the base assembly 2 Push it in at the top between the retaining ribs that hold the assembly in place in a vertical posi tion 8 Remove the drain hose 8 from the bottom of the unit Bend and flex it to loosen the internal calcium depos...

Page 15: ...CTS IN WORKMANSHIP OR MATERIALS FURNISHED BY YOUR INSTALLER AS CONTRASTED TO DEFECTS IN THE HUMIDIFIER ITSELF IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE SHALL BE LIMITED IN DURATION TO THE AFORESAID ONE YEAR PERIOD RESEARCH PRODUCTS CORPORATION S LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OTHER THAN DAMAGES FOR PERSONAL INJURIES RESULTING FROM ANY BREACH OF TH...

Page 16: ...utomatic humidifier Aprilaire High Efficiency Air Cleaners Nobody Makes Clean Air Easier Delivers the cleanest healthiest air ever available from a whole house air cleaner THE BEST IN INDOOR AIR COMFORT Aprilaire Zone Control Systems Custom Comfort Throughout Your Home The most reliable way to achieve temperature control in every area of your home Aprilaire Energy Recovery Ventilator Only The Fres...

Page 17: ...SERVICE AND WATER PANEL REPLACEMENT RECORD Date Dealer Name ...

Page 18: ...SERVICE AND WATER PANEL REPLACEMENT RECORD Date Dealer Name ...

Page 19: ...DP 10005406 Printed in U S A P O BOX 1467 MADISON WI 53701 1467 Products For Better Indoor Air Quality ...

Reviews: