background image

 

THIS IS NOT A PERSONNEL 

LIFT AND NEVER SHOULD BE 

USED FOR HOISTING OR 

MOVING PEOPLE. 

OPERATOR SAFETY INSTRUCTIONS

 

IMPORTANT

 Read and understand this 

instruction manual prior to operating or 

performing maintenance on this lift!  

1. INSPECT THE EQUIPMENT

 

Prior  to  each  use  of  the  unit,  check  all 
moving parts and wire rope to ensure that 
they are in proper operating condition.  

If  a  unit  has  visible  damage  or  does  not 
transfer  up  and  down  smoothly  during  
pre-operation, 

do not use the unit!

 

If cable is kinked, worn, frayed, damaged, 
or has any debris on it that would obstruct 
its  rotation  around  the  pulley  wheels, 

do 

not use the unit!

 

Each  unit  should  have  a  complete  set  of 
caution  decals  and  a  legible  Operators 
Manual.  Contact  Applied  if  any  of  these 
items are missing. 

Do  not  misuse  the unit.  Perform  only  the 
functions  for  which  the  unit  is  designed. 
Never  attempt  to  operate  the  equipment 
at more than the recommended capacity. 

DO NOT EXCEED RATED CAPACITY!

 

KEEP HANDS AWAY FROM 

ALL MOVING PARTS WHILE 

OPERATING UNIT.

 

NEVER ATTEMPT TO WORK ON 

CABLE OR PULLEY SYSTEM 

UNLESS MAST ASSEMBLY IS IN 

THE LOWEST POSSIBLE       

POSITION.

 

Use  only  Applied  replacement  parts.    
Non-OEM parts will severely compromise 
the  quality  and  safety  designed  into  this 
lift. 

2. WORK AREA HAZARDS

 

Never 

operate 

during 

high 

wind           

conditions. Lifting loads during high winds 
can  result  in  the  lift  tipping  over  and  the 
possibility of operator injury. 

Operate  only  on  level  surfaces.  Use  the 
unit  on  smooth  and  level  surfaces  to 
avoid  unit  tipping over  and  the possibility 
of operator injury. Do not operate from an 
unstable platform. 

Always  watch  for  and  avoid  overhead 
wires  and  obstructions  when  using  the 
unit or moving unit to and from the event 
site. 

Do  not  use  unit  to  support  ladders,  for 
climbing, hoisting or people moving. 

Do  not  use  unit  outside  in  thunder,     
lightning or severe weather. 

Summary of Contents for L-16 Series

Page 1: ... 0008 www appliednn com Applied L 16 Series Hand Winch Lifts November 2019 Three Section 16 Hand Winch Lift Certified Load 500 lbs at any height Loading Height 6 1 2 Maximum Lift Height 16 Footprint 84 Folded Dimensions 12 5 x 12 5 x 77 Weight 95 lbs Cable 3 16 Steel ...

Page 2: ......

Page 3: ...ch the unit is designed Never attempt to operate the equipment at more than the recommended capacity DO NOT EXCEED RATED CAPACITY KEEP HANDS AWAY FROM ALL MOVING PARTS WHILE OPERATING UNIT NEVER ATTEMPT TO WORK ON CABLE OR PULLEY SYSTEM UNLESS MAST ASSEMBLY IS IN THE LOWEST POSSIBLE POSITION Use only Applied replacement parts Non OEM parts will severely compromise the quality and safety designed i...

Page 4: ...Figures 2 3 The L 16 lift and winch assembly are packaged separately The lift is shipped with the steel cable installed Take care when removing the winch from the carton as the lift leveling feet and other small parts are packaged with the winch Attach winch to the platform mounting channel using 3 3 8 x 1 1 4 bolts provided See Figure 1 Figure 2 Figure 3 3 LEG ASSEMBLY Install leveling feet to th...

Page 5: ...multaneously all lifts must be raised evenly Three safety pins are provided for use when raising and lowering the lift These must be used to insure safety in the event of cable failure As you raise the lift insert a safety pin into the first hole in the 2 tube Then insert a 2nd pin into the next hole down as it becomes visible When the 3rd hole becomes available remove the first safety pin and ins...

Page 6: ...in flush to the end of the safety swag The secondary safety swag should NOT be in contact with the ball and shank swag If there is no gap between the safety swag and the ball and shank or if the cable is not flush with the safety swag remove the lift from service Always replace any bent or broken parts immediately These parts are available and should be purchased through the Applied Electronics de...

Page 7: ...5 CABLE ROUTING Figure 5 Figure 6 ...

Page 8: ... 205316 N Bolt 205332 P Rope Clamp Kit 5243506 Q Gear Cover G Series 406114 S Reel 306075 T Locknut 204803 U Bolt 205167 V Flat Washer 205055 W Pawl 404166 X Spacer 404166 Y Spring 204363 Z Reel Spacer 207183 AB Bolt 203161 AC Reel Spacer 204807 AH Lockout Lever optional 404579 AJ Spacer optional 404166 AL Base 404896 AM Bushing 204009 AQ Gear Cover optional 5240122 AR Spacer Washer 204360 AS Reel...

Page 9: ... Screw 8 x 1 2 91 066 16 4 Cable Pulleys 2 1 2 91 024 1 5 Pin Clevis 1 2 x 1 1 2 91 310 1 6 Pin Slotted Roll 5 32 x 3 4 91 304 2 7 L 16 Steel Lock Collar Sheet Metal Part 96 000 1 8 L 16 Thumbscrew 3 8 16 x 1 1 4 91 328 1 9 Top Plastic Insert Machined Square HDPE 4 91 039 1 L 16 REPLACEMENT PARTS L 16 TOP MAST PARTS SHEET ...

Page 10: ...91 310 3 4 SAE Hex Nut Nylock 5 16 18 Thread 91 063 2 5 SAE Hex Cap Bolt 5 16 18 x 4 Grd 5 91 081 2 6 Machine Screw 8 32 x 5 8 Lg Zinc 91 074 12 7 Sheet Metal Screw 8 x 1 2 Lg Zinc 91 066 12 8 Lower Bushing 3 8 Width 2 7 8 91 335 2 9 Lower Bushing 3 8 Width 1 7 8 91 334 4 10 Upper Bushing with Nut 3 8 Width 1 7 8 91 336 6 11 Cable Pulleys 1 1 2 Lg 91 023 2 12 Cable Pulleys 2 1 2 Lg 91 024 1 ...

Page 11: ... 91 337 2 12 Pin Slotted Roll 5 32 x 3 4 Pin 91 304 2 13 Winch DLB1200A 92 505 1 14 SAE Hex Cap Bolt 3 8 16 x 3 5 Grd 8 92 078 7 15 SAE Hex Nut Nylock 3 8 16 Thread 91 060 8 16 SAE Hex Cap Bolt 5 16 18 x 5 Grd 5 91 082 2 17 Caster Wheel Sleeve 1 2 Dia x 1 1 2 91 610 2 18 Caster Wheel 3 8 x 1 1 4 91 601 2 19 Flat Washer 3 8 Standard Flat Washer 91 010 2 20 Plastic Tube Cap 2 Square Cap Black 91 317...

Page 12: ...10 L 16 REPLACEMENT PARTS L 16 BOTTOM MAST PARTS SHEET continued ...

Page 13: ...L 16 HAND WINCH LIFT DETAIL ...

Reviews: