LED Indicators (Receiver) 
Power LED:

 Indicates that voltage is applied to the receiver.  

 

Learn LED: 

LED blinks when in the learn mode.

 

Relay LED’s :

 They indicate for each relay whether the relay is activated. 

Data LED

:  LED indicates reception of RF signal at the receivers frequency of 

operation.  For troubleshooting purposes, it can indicate the following: 

1)

 

Whether the transmitter is actually transmitting. 

2)

 

Whether there are interfering signals at the receiver’s frequency of 
operation.  The LED should be dim if the transmitter has no input 
activated or button is not being pressed.  Any LED indication would 
indicate that an interfering signal is present, the severity of which is 
indicated by how much the LED is activated. 

 

 

Controlling 120V Circuits and High Amperage Loads 

The SF900C transceiver is not UL listed, and 110 Volt or higher voltage circuits 
should not be directly connected to the unit.  These high voltage circuits can be 
controlled however by using a contactor with a 24-VAC coil (AW PN 269006, 
30A contactor).  For low voltage loads over 10 Amps, Applied Wireless offers 
high current relays (AWPN 269007, 30A 12VDC Relay) that can be controlled 
by the SF900C. 

 

Receiver Package Information 

 
 

 

 
 
 
 
 

NC-Normally Closed Contact 
C1- Common Contact 
NO- Normally Open Contact- 
Terminal Strips may be “unplugged” for ease of installation

 

 

 

 

Summary of Contents for SF900C

Page 1: ...hese limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not ins...

Page 2: ...tation of the unit will have a significant influence on reception particularly at longest ranges For best results the antennas should be positioned vertically pointing either up or down If necessary u...

Page 3: ...est to the EN position and each of the dip switches must be moved up or down To disable the alternate frequency selection the enable jumper must be moved to the two pins farthest from the EN location...

Page 4: ...not being pressed Any LED indication would indicate that an interfering signal is present the severity of which is indicated by how much the LED is activated Controlling 120V Circuits and High Amperag...

Page 5: ...Optional Products AW Part Number Description Volts Current 610442 SAT AC Power Adapter 120VAC Input 12 VDC 500 mA 610347 AC Power Adapter 120VAC Input 24 VDC 800 mA 610300 AC Power Transformer 120VAC...

Page 6: ...ly activate a relay s for activating pump motor light or other device 12 Application Circuit Loopback Mode In loopback mode the relay is activated as in the earlier example However in Loopback mode a...

Page 7: ...use 7 Any cost or expense related to trouble shooting to determine whether a malfunction is due to a defect in the product itself in the installation or any combination thereof 8 Any cost or expense...

Page 8: ...arly indicated on the outside of the shipping container Any product returned without an RMA number will be refused delivery 3 In order for AW to perform service under warranty you must include the fol...

Reviews: