STR Hardware Manual
920-0030E
2/3/2010
Connecting to Indexer with Differential Outputs
(Many High Speed Indexers have Differential Outputs)
Connecting to Indexer with Sinking Outputs
STR
+V OUT
DIR+
DIR
DIR-
STEP+
STEP
STEP-
Indexer
with
Sinking
Outputs
STR
DIR+
DIR+
DIR-
DIR-
STEP+
STEP-
STEP+
STEP-
Indexer
with
Differential
Outputs
Connecting an Input to a Switch or Relay
STR
switch or relay
(closed=logic low)
EN-
EN+
5-24
VDC
Power
Supply
-
+
Connection Examples: EN