4. Connect the meter cable
: Remove the valve cover
and strain relief cover on rear of valve. Bring meter
cable through the knockout hole in the back of the
valve and connect to the three-pin connection labeled
“METER” on the PC board. Weave the meter cable
through the strain relief and replace the cover and
fastening screw
.
Ensure meter cable is connected to the meter
assembly.
See “Meter Service Instructions” in the
“Control Valve Service Instructions” section of this
manual for detailed meter disassembly and
reassembly instructions.
5. Install piping between meter output and point of use.
Operating Do’s and Don’ts
DO:
Monitor system and keep a log.
Maintain proper water pressure for backwashing.
DON’T:
Permit oils or fats in feed water.
Shut down system for extended periods.
Exceed operating pressures or temperatures.
Backwash filter with insufficient water flow.