Applied Digital,  Inc. 19315  North State hwy 413  Branson West, MO 65737 

417-297-0361  Fax  816-337-3398    E-Mail: 

[email protected]

  web:www.appdig.com   

Connecting  Multiple  T-Max®  G2  Modules  to a T-Max®  Manager  or T-Max®  Manager/Pro 

 

Decide where you want the T-Max®  Manager and timers  to be installed in the rooms. DO  NOT  run the modular  cables through your 
walls as described in your manuals. 

 

 
 
 
 
 
 

 

 

 

 

 

 
 
 
 
 
 

 

Once the system is installed, auto address the system as described in your T-Max®  Manager or T-Max®  Manager/Pro manual. 
Operate the system as normal. 

 

Expandi ng  an Existing  T-Max®  Installation  with  G2s 

 

Using the G2  wireless  system, you can expand a current T-Max®  Series without running additional wires to your new rooms. Simply 
connect a G2  system to the end of your current T-Max®  daisy chain, then connect a G2  system to the new T-Max®  3A or tanning bed 
with a T-Max®  timer  built in. If you are adding a tanning bed with the G2  Access point installed, you don’t need to add anything else. 

 
 
 
 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 

Troubleshooting 

 

If, after installing  the system, you do not get communications between units: 
 
1) M ake sure all units and timers are getting power and properly connected to the tanning units. 
2) M ake sure the data lights on the G2 Access Points are flashing. If there are lights on but none are flashing  rapidly, it may be necessary to move the 
G2 Access Point unit to another location. M ove the G2 access Point unit until the data light starts flashing. 
3) M ake sure the distance between the G2 Access Points connected to the T-M ax® M anager and the furthest wireless module does not exceed  300 
feet. You may need to move the G2 access Point. 
4) M ake sure the G2 Access Points units are at least 2 feet apart from each other.  
5) If you are connecting G2 systems units on multiple floor levels, make sure the G2 Access Points units are not directly above the G2 Access Points 
unit that is connected to the T-M ax® M anager.  
6) The Frequency of the G2 Access Points units may have to be changed.  Contact Applied Digital Technical  Support for instructions. 

 

 

 

 

Note

  If the tanning bed has an in bed T-Max® 

timer,  simply connect the T-Max®  G2  Access 
Point directly to the RJ-22  port on the tanning 
bed.  You  don’t need to add anything if there is 
an in bed T-Max®  Timer  and G2  Access Point 
already in your tanning bed.

 

You can either provide power to the T-Max  Manager and the G2  Power Injector with the power supplies provided with each unit, 
or you can use one power supply to power both. To do this, connect the power supply that provided with the T-Max  Manager to 
one of the power inputs on the G2  Power  Injector. Then connect the optional power patch cable (PN  60000000053)  between the 
open power connector on the G2  Access Point and the power connector on the T-Max  Manager or T-Max  Manager/Pro. 

Address the new timers  as described in the T-Max®  3As or tanning bed users 
guides. It may be necessary to set the maximu m  bed number in the T-Max® 
Manager or Manager/Pro as described in their respective user’s guides.  

Note: 

If  the tanning bed has an in bed T-Max®  timer,  simply 

connect the T-Max®  G2  Access Point directly to the RJ-22  port on 
the tanning bed.  You  don’t need to add anything if there is an in 
bed T-Max®  Timer  and G2  Access Point already in your tanning 
bed.

 

Connect the G2  system to the T-Max® 
Manager using the modular cable 
provided. Do not modify  this cable in 
any way.  

Connect the G2  System to 
each additional T-Max® 
3A as described on page 1.

 

            

                                                           

            

                                                           

Connect the G2  system to the T-Max®  3A 
or last timer  in your current daisy-chain 

Connect the G2  system to 
each additional T-Max® 
3A as described on page 1.  

  

   

            

                                                           

  

   

            

                                                           