Gas adjustment (Conversion to LPG)
All work must be carried out by an Authorised
Service Agent.
IMPORTANT: Always isolate the hob from the electricity supply
before changing the injectors and/or adjusting the minimum
flow of the burners.
o
Remove the pan-stands, burners and
flame spreaders (A).
o
Unscrew the injector (B) and replace it
with the stipulated injector for the new gas
supply (see table on next page).
GENERAL INJECTORS TABLE
Kind of gas Ø injectors Burners Power
(MJ/h)
Natural
1.55
0.90
1.18
Rapid
Auxiliary
Semi-rapid
11.9
4.0
7.0
L.P.G.
Butane
Propane
0.90
0.53
0.69
Rapid
Auxiliary
Semi-rapid
10.8
3.6
6.3
o
Reassemble all the burners carefully; in particular you should
make sure that the flame spreader is correctly placed on the
burner.
18