User’s Guide

 

 

Rev.A4 

FIRMWARE REVISIONS 

 

AT2811 

LCR Meter

 

 

 

 

Applent Instruments Ltd. 

Address: Baolong International FL3, Zhonglou   
District, Changzhou, Jiangsu, China (PRC)   
Post Code: 213000   
Tel: 0086-0519-88805550   
Fax: 0086-0519-86922220 
Sales Email: [email protected]   
Tech Email: [email protected]   

http://www.applent.com

Summary of Contents for AT2811

Page 1: ...Meter Applent Instruments Ltd Address Baolong International FL3 Zhonglou District Changzhou Jiangsu China PRC Post Code 213000 Tel 0086 0519 88805550 Fax 0086 0519 86922220 Sales Email sales applent com Tech Email tech applent com http www applent com ...

Page 2: ... for the customer s failure to comply with these requirements Ground The Instrument To avoid electric shock hazard the instrument chassis and cabinet must be connected to a safety earth ground by the supplied power cable with earth blade DO NOT Operate In An Explosive Atmosphere Do not operate the instrument in the presence of inflammable gasses or fumes Operation of any electrical instrument in s...

Page 3: ...this product must be returned to a service facility designated by Applent The buyer shall prepay shipping charges to Applent and Applent shall pay shipping charges to return the product to the Buyer However the Buyer shall pay all shipping charges duties and taxes for products returned to Applent from another country Applent warrants that its software and firmware designated by Applent for use wit...

Page 4: ...ures Overview 8 3 Start up 9 3 1 Front Panel 9 3 1 1 Front panel description 9 3 2 Keypad 10 3 3 Rear Panel 10 3 4 Power ON OFF 11 3 4 1 Power up 11 3 4 2 Warm up time 11 3 5 Connect to Device under Test 11 3 6 To select principal and AUX parameter 11 3 7 To set up test frequency 12 3 8 AUTO and Manual range 12 3 9 To select test speed 12 3 10 Clear zero 12 3 11 Setup 13 3 11 1 To setup sorting 14...

Page 5: ...ed items supplied with the meter have been provided as per the specified optioned Table 1 1 Included Accessories NAME QTY REMARK User s Manual 1 AC Power Cord 1 220V 50Hz Fuse 2 0 5A Slow Blow ATL501 Kelvin Test Leads 1 Test Report 1 If there is damaged or shortage in accessories please contact Applent Sales Department or retailer 1 2 Power Supply Requirements Confirm that the power supplied to th...

Page 6: ...y Range 95 RH at 40 C Technical index Temperature 23 C 5 C Technical index Humidity 70 RH 1 5 Cleaning To prevent electrical shock disconnect the AT2811 power cable from the receptacle before cleaning Use a dry cloth or a cloth slightly dipped in water to clean the casing Do not attempt to clean the AT2811 internally WARNING Don t Use Organic Solvents such as alcohol or gasoline to clean the Instr...

Page 7: ...and quality control institution The AT2811 can output comparison decision results for sorting components into 5 bins 2 2 Main Specifications The AT2811 technical specifications including the basic technical specifications of the instrument and equipment testing allows These specifications are in the instrument factory can achieve Please refer to Chapter 4 for complete technical specifications Test...

Page 8: ...Can display main and AUX parameter simultaneously with 5 digits A L C R Z B Q D correcting feature Short and open full frequencies correction Comparator sorting function 5 bins sorting results 3 bins percent GD bin 1 bin auxiliary bin and 1 bin NG bin Comparator function display LED display Beep Can setup all comparator results beep ...

Page 9: ... Panel 3 1 1 Front panel description Figure 3 1 Front panel 1 State indicator range NO speed range equivalent mode and frequency indicator 2 Principal parameter display window 0 8 inches LED display 3 AUX parameter display window 0 5 inches LED display 4 Sorting indicator 5 Test terminal 6 Beep indicator 7 Direction key 8 Principal function key 9 Power switch ...

Page 10: ...lect AUTO and Manual range Speed Select test speed Slow and fast speed is available Setup Enter sorting and other function setup Clear Zero Enter Zero page Select range ESC Return to test state from setup page Enter Confirm option or input 3 3 Rear Panel Figure 3 3 Rear Panel 1 RS232C reserved port not available for AT2811 2 Fuse Holder 250V 0 5A fuse 3 AC Power Cord Receptacle ...

Page 11: ...that comes with the instrument please connect to device same as the following Figure 3 4 Test terminal Warning Do not apply DC voltage or current to the UNKNOWN terminal Applying DC voltage or current may lead to device failure Warning The capacitors should be discharged before connected to the terminals 3 6 To select principal and AUX parameter Under measurement state press FUNC key to select fir...

Page 12: ...ay digits Current measurement pre two value Current display digits 4 33 5 5 30 4 3 7 To set up test frequency Frequency accuracy 0 02 Press freq and then display in circulation at frequency indicator 100Hz 120Hz 1kHz 10kHz 3 8 AUTO and Manual range Press AUTO to switch AUTO and hold range Auto indicates current state when AUTO indicator is lighted it means AUTO range is used when AUTO indicator is...

Page 13: ... circuit your test clip if previous state is SHORT clear please OPEN circuit your test clip if previous state is OPEN clear please SHORT circuit your test clip press Enter again and wait for about 20 seconds then clearing finishes and return to test state Press ESC key to terminate clearing process After clearing is completed clearing value is saved in the internal memory of the instrument Details...

Page 14: ...meter window displays 15 00 BEEP Beep setup OFF turn off P1 PASS bin P1 beep P2 PASS bin P2 beep P3 PASS bin P3 beep AU AUX parameter FAIL beep NG Principal and AUX parameter is all FAIL beep SrES Source Resistance setup 100 100Ω Source Resistance 30 30Ω Source Resistance LEVEL Signal Level setup 0 1 0 1V 0 3 0 3V 1 0 1 0V EQU Equivalent Circuit setup SER series equivalent PAL parallel equivalent ...

Page 15: ... 3 5 Sorting flow 3 11 2 Input sorting value Figure 3 6 Input filed Press to choose digit bit Press to increase or decrease number or change unit Press ESC to return to main menu Press Enter key to save data and return to main menu Note if lower limit P1 L P2 L P3 L is minus deviation users need to input 0 0000 Press Enter key to enter submenu current value decimal point or unit flickers std ...

Page 16: ... Lmin Lx 1 1 Qx 2 kf Z 0 25 1 Zx Zmax Zmin Zx 2 kf R 0 25 1 Rx Rmax Rmin Rx 1 Qx 2 kf D 0 0025 1 Zx Zmax Zmin Zx 1 Dx Dx2 2 kf Q 0 0030 1 Zx Zmax Zmin Zx Qx 1 Qx 2 kf Where 1 L C R Z is relative error D Q is absolute error 2 Subscript that is X is this parameter s measured value Subscript that is max is maximum value min is minimum value 3 kf frequency factor Measured parameter maximum value and m...

Page 17: ... AUX parameter 5 digits Test speed Slow 3 times second Fast 10 times second Source Resistance 30Ω and100 MAX reading 33000 Range AUTO and Manual Equivalent Circuit In series and parallel Correction Short and open sweep frequency correction Comparator 5 bins P1 P2 P3 AUX NG Beep P1 P2 P3 AUX NG OFF Environment index temperature 18 28 humidity 65 RH Operating temperature 10 40 humidity 10 80 RH Stor...

Page 18: ...AT2811 User s Guide 18 4 3 Dimension Figure 4 1 Dimension AT2811 User s Guide 2005 2016 Applent Instruments Ltd ...