OPERATION 
AC Current Measurement 
 

1. Set the DMM at ACV Function and proper  
     range. 
2. Connect the plug of transducer with DMM  
    firmly. 
3. Press the trigger to open transformer jaws 
    and clamp one conductor only, making  
    sure that the jaw is firmly closed around  
    the conductor and reading the result from 
    the digital display of DMM.  

 

MAINTENANCE 

To keep the instrument clean , wipe the case  

with a damp cloth and detergent , do not use 

abrasives or solvents. 

Any adjustment , maintenance and repair  

shall be conducted by a service personnel

Meter Safety 

 
Terms marked on Equipment. 

 

 

ATTENTION

 — Refer to Manual. 

 

 

DOUBLE INSULATION

 — Protection   

                                                    Class II. 

  

DANGER

 - Risk of electric shock. 

 

Symbols in this Manual 

 

 

 This symbol indicates where cautionary 

or other information is found in the manual. 
 

SPECIFICATIONS 
Current Range :

0.1A to 400A a.c. RMS. 

Output Voltage :

1mV a.c. per 1Amp a.c. 

Working Voltage : 

600V CAT. II per IEC  

                               1010-1 

Maximum Altitude : 

2000m 

Operating Temperature : 

0

 to 45

<75% 

                                                R.H. 

Storage Temperature : 

-20

 ~ 60

 