Aponorm BASIS PLUS BLUETOOTH Instructions For Use Manual Download Page 3

3

Switches, housing and accessories

1

 On/off switch

2

 Display

3

 M button (Memory)

4

 MAM/Multiple measurements & 

  time selection button

5

 User selection button

6

 Cuff connection

7

 Mains adapter connector

8

 Battery compartment

9

 Cuff

10

 Cuff tube

11

 Cuff connector

aponorm

®

 

Basis Control Plus

BF part.

Important! Please observe the information in this booklet in order to 

prevent damage to the device and avoid error messages. 

Protect from moisture.

Before use, carefully read the operating 
instructions.

Display indication

12

 Systolic value

13

 Diastolic value

14

 Pulse indicator

15

 MAM mode (multiple measurement mode active)

16

 Battery level warning light

17

 Cuff seating check

  -A Optimum cuff seat
  -B Less than optimal cuff seat
  -C Arm movement disturbance indicator «Err 2»
  -D Cuff signal disturbance indicator «Err 1»
  -E Cuff pressure disturbance indicator «Err 3»

18

 Pulse arrhythmia detector (PAD)

19

 MAM waiting time symbol

20

 Blood pressure traffic light indicator

21

 Pulse measurement active

22

 User selection display

23

 Stored value

24

 Date/time display

Summary of Contents for BASIS PLUS BLUETOOTH

Page 1: ...for increased measuring reliability Functional warranty of 2 years on the cuff as a wear part Traffic light display Traffic light 2 users Arrhythmia detection storage slots Instructions for use Also...

Page 2: ...aponorm Basis Control PLUS 2 10 11...

Page 3: ...otect from moisture Before use carefully read the operating instructions Display indication 12 Systolic value 13 Diastolic value 14 Pulse indicator 15 MAM mode multiple measurement mode active 16 Batt...

Page 4: ...instrument was developed in collaboration with physicians and clinical tests prove its mea surement accuracy to be of a very high standard If you have any questions or problems or want to order spare...

Page 5: ...hythmia detector PAD 10 4 Data memory 11 Viewing the stored values 11 Clearing all values 11 5 Battery indicator and battery change 11 Batteries almost flat 11 Batteries flat battery replacement 11 Wh...

Page 6: ...plays the time 24 The date however is only required for the memory display If you want to change the date and time again press and hold the MAM time button 4 down for approx three seconds until the ye...

Page 7: ...order to return to the normal mode indi vidual measurement press the MAM button again until the MAM symbol is no longer displayed During the measurement in the MAM mode the number 1 2 or 3 at the bott...

Page 8: ...pressure 1 Press the On off button to start the measure ment 1 2 The cuff will now inflate automatically Relax do not move and do not tense your arm musc les until the measurement result is displayed...

Page 9: ...logist Manual inflation In case of very high systolic blood pressure e g exceeding 135 mmHg it can be of use that you determine the pressure yourself Press the On off button after the monitor started...

Page 10: ...tores the last 99 readings for each user Viewing the stored values Press the M button 3 briefly while the monitor is switched off Now the display changes over to the data memory display indicated by M...

Page 11: ...tery sym bol 16 will flash as soon as the device is switched on You cannot take any further measurements and must replace the batteries In the event of a battery change or power failure the memory ret...

Page 12: ...nto the wall socket When the mains adapter is connected no battery current is consumed We recommend to have batteries in the monitor even with mains operation just as a back up They ensure that in the...

Page 13: ...naccurate and no result can therefore be displayed Read through the check list for perfor ming reliable measure ments and repeat the measurement Error Designa tion Potential cause and remedy ERR 6 MAM...

Page 14: ...itted to your arm Do not use this monitor close to strong elec tromagnetic fields such as mobile telephones or radio installations We recommend obser ving a minimum distance of 3 3 m from such devices...

Page 15: ...s Monitor care Clean the monitor with a soft dry cloth only Cleaning the cuff Remove stains on the cuff carefully with a damp cloth and soapsuds or a commercial disinfectant WARNING Do not wash the cu...

Page 16: ...rming part of the product We grant a functional guarantee of 2 years on the cuff tightness of the inner chamber Warranty term The warranty covers a period of 5 years from the date of purchase warranty...

Page 17: ...the Federal Republic of Germany Date 02 2019 10 Technical data Operating 10 40 C 50 104 F conditions 15 95 relative maximal humidity of air Storage 20 55 C 4 131 F conditions 15 95 relative maximum hu...

Page 18: ...18 Average monitor 5 years or life 10 000 measurements accessories 2 years This monitor complies with the requirements of the Medical Device Directive 93 42 EEC Technical alterations reserved...

Page 19: ...ife ch Functional overview Important advice Inthedownloadareaofwww aponorm deyoufindtheseinstructionswithupdates alsoindigitalformfordownload alsoinGerman Turkish FrenchandRussian Homepage Cuff check...

Reviews: